Xinchao Cui

Xinchao Cui

Auto-generated profile, based on publicly available information

Xinchao Cui

School of Artificial Intelligence and Automation, Huazhong University of Science and Technology 1 , Wuhan 430074

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XCXinchao Cui
Xinchao Cui
LLLan Li
Lan Li
WLWenzhong Liu
Wenzhong Liu
In this study, a real-time detection method for amol biomolecules based on 2nd and 3rd harmonics of water-based magnetic nanoparticles (MNPs) is reported. In previous magnetic immunoassay methods based on magnetic particle spectroscopy (MPS), the 1st harmonic was affected by the diamagnetic environment and would easily interfere with the signal at a concentration lower than pM MNPs. We propose to use the ratio of the 3rd to 2nd harmonics to achieve more sensitive immune detection by using an AC plus DC excitation magnetic field. We found that a homemade magnetic particle spectrometer can ensure that the signal-to-noise ratios of the 2nd and 3rd harmonics are roughly the same by modulating the DC magnetic field to compare and adjust the amplitudes of the 2nd and 3rd harmonics. The immunoassay sensitivity was greatly improved, and the ability of magnetic immunoassay based on water-based MNPs to detect trace biomolecules was roughly estimated using the limit of detection (LOD) for 0.4 pM (40 amol) biomolecules in a 100 μL suspension, by binding streptavidin to biotin. In addition, the entire test is completed within 1 s, which will be useful in testing for viral aerosols in the air.

16 December 2024 in Applied Physics Letters
Verified
Journal Article
Closed access
YYYulin Yang
Yulin Yang
JCJiajun Cui
Jiajun Cui
XCXinchao Cui
Xinchao Cui
WLWenzhong Liu
Wenzhong Liu
BTBo Tian
Bo Tian
JZJing Zhong
Jing Zhong
Magnetic nanoparticle (MNP) agglutination-based optomagnetic biosensing has been applied for rapid and sensitive detection of various biomolecules. However, the underlying physics of optomagnetic biosensing remains a hurdle, especially when the size of MNPs approaches the laser wavelength, i.e., the scattering enters the Mie regime. In this study, we propose a numerical model by combining the Fokker–Planck equation and the T-matrix to explain the effect of Mie scattering on the optomagnetic signal of the agglutinated MNPs. It indicates that the orientation-dependent Mie scattering of the MNP dimer leads to an inverse optomagnetic response compared to that of the MNP monomer. The inverse optomagnetic response can dominate with the enhancement of Mie scattering. To verify the numerical model, biotinylated bovine serum albumin (biotin-BSA) is applied to agglomerate streptavidin-coated MNPs in a standard biosensing strategy representing the immuno-agglutination assay. Guided by the model, a proportion-based signal analysis is proposed to improve the performance of the MNP agglutination-based optomagnetic biosensor, which provides a picomolar detection limit for biotin-BSA (∼0.1 ng/mL) with a total assay time of 8 min, paving the way for more accurate point-of-care diagnosis.

9 April 2026 in Analytical Chemistry
Verified
Journal Article
Closed access
QBQin Bi
Qin Bi
YYYulin Yang
Yulin Yang
LSLiyang Shi
Liyang Shi
XLXinli Liu
Xinli Liu
ZZZheyuan Zhou
Zheyuan Zhou
BTBo Tian
Bo Tian

26 December 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XCXinchao Cui
Xinchao Cui
CLChong Lu
Chong Lu
CLChunping Liu
Chunping Liu
RBRyszard Buczynski
Ryszard Buczynski
WLWenzhong Liu
Wenzhong Liu
Magnetic nanoparticles (MNPs) are temperature sensitive, making them useful as probes for measuring cellular temperature. In this paper, we propose a remote non-invasive thermometer that replaces a traditional magnetic sensor with linearly polarized light as the transmission medium, utilizing the Faraday rotation of MNPs. This method not only overcomes the limitations of distance on temperature measurement accuracy but also offers strong anti-interference capabilities. Using this thermometer, we measured the cooling process of MNPs within a temperature range of 310–316 K, achieving an estimated temperature root mean square error (RMSE) of 0.14 K. This approach shows promise for integration with microscopy systems for temperature imaging of cells or biological tissues, potentially revealing new biological insights.

1 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XCXinchao Cui
Xinchao Cui
QDQinhong Dai
Qinhong Dai
Joanna ChwiejJoanna Chwiej
Joanna Chwiej
RBRyszard Buczynski
Ryszard Buczynski
WLWenzhong Liu
Wenzhong Liu

7 October 2026 in ACS Nano
Verified
Journal Article
Closed access
YYYulin Yang
Yulin Yang
QBQin Bi
Qin Bi
KQKe Qin
Ke Qin
GJGuang Jia
Guang Jia
QGQian Gao
Qian Gao
BTBo Tian
Bo Tian