Hybrid ac/dc microgrids (HMGs) have emerged as a promising paradigm for integrating large numbers of inherently uncertain and correlated renewable energy sources (RESs). To address the uncertainty introduced by extensive RES integration, a quad-level energy management model is proposed for HMGs, incorporating a novel data-driven uncertainty set. Specifically, a pair convex hull uncertainty set (PCHUS) is developed with adjustable size, which utilizes a graph neural network to identify and exclude outliers in RES data. This approach provides trustworthy RES data at any given confidence level. Then, a quad-level energy management model is designed to determine the minimal-size PCHUS among all possible options, ensuring the least conservative solution, while maintaining robustness against RES fluctuations. Furthermore, a modified version of Taguchi’s orthogonal array testing (TOAT) method, termed quasi-TOAT, enhances the proposed solution algorithm. This modification enables parallel processing capabilities, significantly improving both the global optimum-seeking process and computational efficiency. To validate the proposed approach, the proposed uncertainty set and enhanced algorithm are compared against existing methods using a practical HMG case study. The results demonstrate the effectiveness and superiority of the proposed methodology in managing uncertainty within HMGs.
4 March 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Compared with conventional HVDC systems, the hybrid multiterminal HVDC (Hybrid-MTDC) system has a more sophisticated network topology composed of line commutated converter (LCC) and modular multilevel converter (MMC) stations, which leads to DC fault discrimination being difficult and ambiguous. Furthermore, for long transmission lines, high fault resistances and different converter impedance characteristics, the reliable discrimination of external and internal faults located at the remote end and T areas is particularly demanding. Therefore, considering the frequency characteristics of DC boundaries and equivalent converter impedances and DC line models, this paper constructs a time-domain convolution power. The performance of the convolution power in various fault scenarios is mathematically elaborated. Due to its good decomposition ability for short-time nonstationary signals, wavelet decomposition is utilized to extract the specific frequency bands of traveling waves; thus, the convolution power in different frequency bands can be calculated. On this basis, a convolution power-based protection scheme is proposed for identifying external and internal faults, locating a DC bus fault and selecting faulty poles. PSCAD/EMTDC simulation results show that various DC faults can be correctly identified within 3 ms, and the proposed scheme has high reliability and sensitivity, which is beneficial for the protection of Hybrid-MTDC systems.
Cutter suction dredgers are important pieces of rock excavation equipment in port and waterway construction. It is valuable but difficult to properly estimate the cutting force on the chisel pick of the cutter suction dredger. In this paper, an analytical model, called the crushed zone expansion induced tensile failure model (CEIT model), is proposed for rock cutting with a chisel pick in order to predict the peak cutting force (Fc) more accurately. First, a review of the existing models for rock cutting with a chisel pick is presented. Next, based on the tensile breakage theory, cavity expansion theory and some hypotheses, the mathematical formula of the CEIT model is obtained. Different from that in the previous models, the effect of the rock on both sides of the chisel pick on Fc, defined as the sidewall effect is considered in the CEIT model. Then, the predicted Fc by the CEIT model is compared with the predicted Fc by existing theoretical models and experimental results to check the validity of the CEIT model. The results show that the CEIT model can well capture the relationships of Fc to the cutting parameters, including cutting width, cutting depth, and rake angle, and can predict the experimental results much better than the existing models. Finally, the sidewall effect and its influence factors according to the CEIT model are discussed.
6 June 2025 in IEEE Transactions on Sustainable Energy
The penetration of inverter-based resources (IBRs) into the grid is experiencing significant growth. Their control behavior during unbalanced grid conditions can impact system stability and protection. This paper evaluates the performance of prevalent grid-forming control-based IBRs (GFM-IBRs) under unbalanced grid conditions and proposes novel insights in a novel framework. First, we investigate the potential impacts of grid-forming control-based IBRs (GFM-IBRs) on system dynamics, protection, and fault ride-through (FRT) capability under unbalanced grid conditions based on extensive literature review and through EMT simulations in benchmark systems with IBRs. To discover these impacts and accommodate unbalanced grid conditions, we implement a generic control structure for full converter-based GFM-IBRs under FRT mode, then perform a comparative analysis of existing solutions that include sequence decomposition methods, positive sequence current-limiting methods, negative sequence controls, and current coordination methods, to identify their capabilities and limitations through literature review and EMT simulations in a large-scale power system. Finally, key challenges and solutions are discussed, highlighting prospects for future research.
16 October 2024 in IEEE Transactions on Energy Conversion
Grid-forming (GFM) controls exhibit robust frequency and voltage support capabilities for inverter-based resources (IBRs). This also shows promise for doubly fed induction generator-based wind turbine generators (DFIG-based WTGs). However, during asymmetrical faults, the DFIG-based WTG that employs GFM controls (GFM-DFIG) might suffer from overcurrent and overmodulation of the rotor-side converter (RSC). Therefore, from the perspective of positive-sequence, negative-sequence, and transient components, this paper proposes asymmetrical fault ride-through (FRT) controls for the GFM-DFIG based on the mechanism for forming the grid voltage. Firstly, internal voltage vectors are designed for the assessment of asymmetrical FRT capabilities. Then a positive- and negative-sequence control (PNSC) is proposed to support the sequence components of internal voltage vectors for the GFM-DFIG. On this basis, an asymmetrical FRT control structure is proposed, incorporating negative-sequence reactive current injection and two types of positive-sequence control schemes: the current saturation-based method and virtual impedance-based method. Additionally, a simplified calculation method for transient voltages is utilized to eliminate the impacts of transient flux leakage. Finally, the proposed FRT controls for the GFM-DFIG are validated by using the EPRI benchmark system. The results indicate that, with the proposed control, GFM-DFIG can maintain stable voltages and achieve required negative-sequence behaviors.
To achieve better control performance, a comprehensive control parameter design method that considers economics, stability and dynamic performance is essential for hybrid multi-terminal HVDC systems. In this paper, a hierarchical model for the control system of Hybrid-MTDC is constructed and the parameters are optimized on two layers. On the system layer, using the normalization processing method, a system-layer objective function that considers both the minimum network loss and the voltage offset is formed for Hybrid-MTDC systems and solved with the proposed penalty interior point method. On the converter layer, using the state-space matrix method, a generic small-signal stability range of each control parameter can be obtained by the traversal calculation of the eigenvalues. Then, to identify the stricter stable operating region for the DC voltage controller under severe conditions, an additional stability criterion based on the mixed-potential theory is deduced, and the design-oriented boundaries are generated and added to the feasible region. Finally, within the design-oriented boundaries, a general dynamic performance evaluation function is constructed to determine the optimal control parameters. Utilizing the proposed method, a typical Hybrid-MTDC system is investigated, and experimental verifications are provided to validate the effectiveness and accuracy.