Ute Ludwig

Ute Ludwig

Auto-generated profile, based on publicly available information

Ute Ludwig

Medical Center, University of Freiburg, Faculty of Medicine, University of Freiburg, Department of Radiology, Medical Physics, Freiburg, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2020 in Clinical Oral Implants Research
Verified
Journal Article
Open access
PDF file
TFTabea Flügge
Tabea Flügge
ULUte Ludwig
Ute Ludwig
JHJan‐Bernd Hövener
Jan‐Bernd Hövener
Ralf KohalRalf Kohal
Ralf Kohal
DWDaniël Wismeijer
Daniël Wismeijer
KNKatja Nelson
Katja Nelson
Objectives: To present a workflow of virtual implant planning and guided implant surgery with magnetic resonance imaging (MRI) and virtual dental models without the use of ionizing radiation.Methods: Five patients scheduled for implant placement underwent an MR examination at three Tesla using individualized 2D and 3D turbo spin‐echo (TSE) sequences and dedicated head coils. The MRI data and virtual dental models derived from either optical model scans or intraoral scans were imported to a virtual implant planning software (coDiagnostiX, Dental Wings, Montreal, Canada). Virtual prosthetic planning and implant planning were performed regarding the hard and soft tissue anatomy. A drill guide was designed on the virtual dental model using computer‐aided design (CAD) and manufactured in‐house, using a 3D printer (Eden 260V, Stratasys, Eden Prairie, MN, USA).Results: The MRI displayed all relevant anatomical structures for dental implant planning such as cortical and cancellous bone, floor of the nasal and maxillary sinus, inferior alveolar nerve and neighboring teeth. The manual alignment of virtual dental models with the MRI was possible using anatomical landmarks. Dental implant planning, CAD/CAM of a drill guide and fully guided implant placement were successfully performed.Conclusions: Guided implant surgery is feasible with MRI without ionizing radiation. Further studies will have to be conducted to study the accuracy of the presented protocol and compare it to the current workflow of guided surgery using CBCT.

18 December 2019 in Clinical Neuroradiology
Verified
Journal Article
Closed access
PDF file
KGKonstanze Viktoria Guggenberger
Konstanze Viktoria Guggenberger
AKAxel Joachim Krafft
Axel Joachim Krafft
ULUte Ludwig
Ute Ludwig
PVPatrick Vogel
Patrick Vogel
SESamer Elsheik
Samer Elsheik
SMStephan Meckel
Stephan Meckel

27 May 2020 in Clinical Oral Implants Research
Verified
Journal Article
Open access
PDF file
TFTabea Flügge
Tabea Flügge
ULUte Ludwig
Ute Ludwig
GWGita Winter
Gita Winter
PAPhilipp Amrein
Philipp Amrein
FKFlorian Kernen
Florian Kernen
KNKatja Nelson
Katja Nelson
Objectives: The objective of this in vitro study was to assess the accuracy of fully guided implant placement following virtual implant planning based on MRI.Material and Methods: Sixteen human cadaver hemimandibles with single missing teeth (n = 3), partially edentulous (n = 6) and edentulous situations (n = 7) were imaged using MRI. MRI and optical scans obtained with an intraoral scanner, were imported into an implant planning software. Virtual prosthetic and implant planning were performed regarding hard‐ and soft‐tissue anatomy. Drill guides were manufactured, and fully guided implant placement was performed. Buccal and lingual bone and implant nerve distance were measured by three examiners in preoperative MRI and postoperative CBCT. The implant position was assessed using a software for deviation of implant positions displayed in CBCT and optical scans, respectively.Results: MRI displayed relevant structures for implant planning such as cortical and cancellous bone, inferior alveolar nerve and neighboring teeth. Implant planning, CAD/CAM of drill guides and guided implant placement were performed. Deviations between planned and actual implant positions in postoperative CBCT and optical scans were 1.34 mm (SD 0.84 mm) and 1.03 mm (SD 0.46 mm) at implant shoulder; 1.41 mm (SD 0.88 mm) and 1.28 mm (SD 0.52 mm) at implant apex, and 4.84° (SD 3.18°) and 4.21° (SD 2.01°). Measurements in preoperative MRI and postoperative CBCT confirmed the compliance with minimum distances of implants to anatomical structures.Conclusions: Relevant anatomical structures for imaging diagnostics in implant dentistry are displayed with MRI. The accuracy of MRI‐based fully guided implant placement in vitro is comparable to the workflow using CBCT.