28 June 2023 in Scientific Reports
Minimally invasive endovascular interventions have become an important tool for the treatment of cardiovascular diseases such as ischemic heart disease, peripheral artery disease, and stroke. X-ray fluoroscopy and digital subtraction angiography are used to precisely guide these procedures, but they are associated with radiation exposure for patients and clinical staff. Magnetic Particle Imaging (MPI) is an emerging imaging technology using time-varying magnetic fields combined with magnetic nanoparticle tracers for fast and highly sensitive imaging. In recent years, basic experiments have shown that MPI has great potential for cardiovascular applications. However, commercially available MPI scanners were too large and expensive and had a small field of view (FOV) designed for rodents, which limited further translational research. The first human-sized MPI scanner designed specifically for brain imaging showed promising results but had limitations in gradient strength, acquisition time and portability. Here, we present a portable interventional MPI (iMPI) system dedicated for real-time endovascular interventions free of ionizing radiation. It uses a novel field generator approach with a very large FOV and an application-oriented open design enabling hybrid approaches with conventional X-ray-based angiography. The feasibility of a real-time iMPI-guided percutaneous transluminal angioplasty (PTA) is shown in a realistic dynamic human-sized leg model.
19 August 2016 in Physics in Medicine & Biology
Magnetic particle imaging (MPI) is a non-invasive imaging modality for direct detection of superparamagnetic iron-oxide nanoparticles based on the nonlinear magnetization response of magnetic materials to alternating magnetic fields. This highly sensitive and rapid method allows both a quantitative and a qualitative analysis of the measured signal. Since the first publication of MPI in 2005 several different scanner concepts have been presented and in 2009 the first in vivo imaging results of a beating mouse heart were shown. However, since the field of view (FOV) of the first MPI-scanner only covers a small region several approaches and hardware enhancements were presented to overcome this issue and could increase the FOV on cost of acquisition speed. In 2014 an alternative scanner concept, the traveling wave MPI (TWMPI), was presented, which allows scanning an entire mouse-sized volume at once. In this paper the first in vivo imaging results using the TWMPI system are presented. By optimizing the trajectory the temporal resolution is sufficiently high to resolve the dynamic of a beating mouse heart.
2 September 2019 in Scientific Reports
Magnetic Particle Imaging (MPI) is a promising new tomographic modality for fast as well as three-dimensional visualization of magnetic material. For anatomical or structural information an additional imaging modality such as computed tomography (CT) is required. In this paper, the first hybrid MPI-CT scanner for multimodal imaging providing simultaneous data acquisition is presented.
24 November 2022 in Nature Communications
Magnetic nanoparticles (MNPs) have been adapted for many applications, e.g., bioassays for the detection of biomarkers such as antibodies, by controlled engineering of specific surface properties. Specific measurement of such binding states is of high interest but currently limited to highly sensitive techniques such as ELISA or flow cytometry, which are relatively inflexible, difficult to handle, expensive and time-consuming. Here we report a method named COMPASS (Critical-Offset-Magnetic-Particle-SpectroScopy), which is based on a critical offset magnetic field, enabling sensitive detection to minimal changes in mobility of MNP ensembles, e.g., resulting from SARS-CoV-2 antibodies binding to the S antigen on the surface of functionalized MNPs. With a sensitivity of 0.33 fmole/50 µl (≙7 pM) for SARS-CoV-2-S1 antibodies, measured with a low-cost portable COMPASS device, the proposed technique is competitive with respect to sensitivity while providing flexibility, robustness, and a measurement time of seconds per sample. In addition, initial results with blood serum demonstrate high specificity.
10 January 2020 in IEEE Transactions on Medical Imaging
Magnetic Particle Imaging (MPI) is a fast imaging technique to visualize the distribution of superparamagnetic iron-oxide nanoparticles (SPIONs). For spatial encoding, a field free area is moved rapidly through the field of view (FOV) generating localized signal. Fast moving samples, e.g., a bolus of SPIONs traveling through the large veins in the human body carried by blood flow with velocities in the order of ~45 cm/s, cause temporal blurring in MPI measurements using common sequences and reconstruction techniques. This hampers the evaluation of dynamics of fast moving samples. In this manuscript, a first study on fast moving samples visualized within an MPI scanner is demonstrated. By optimizing parameters for imaging and reconstruction, the dynamics of a fast moving bolus at different velocities can be visualized with high temporal resolution without blurring artifacts.
2 July 2019 in IEEE Transactions on Magnetics
Magnetic particle imaging (MPI) is a novel tomographic imaging method, which allows determining the distribution of superparamagnetic iron-oxide nanoparticles in three dimensions. So far, various MPI systems have been presented with each one emphasizing different scanner features such as large field of view (FOV) or high resolution. For imaging with both high resolution and a large FOV, the optimization and harmonization of hardware parameters as well as tracer material are key prerequisites. The traveling wave MPI (TWMPI) approach uses an array of electromagnets, which can provide a high magnetic field gradient for a high resolution as well as a mouse-sized FOV at the same time. In combination with the tracer LS-008, which is optimized for the MPI technique, a resolution in the sub-millimeter range can be achieved. In this paper, an optimized scanner is presented based on the TWMPI approach featuring a gradient strength up to almost 10 T/m in an FOV with a length of 45 mm providing a high resolution below 500 microns using the optimized LS-008 tracer.