Nicolas Dupré

Nicolas Dupré

Auto-generated profile, based on publicly available information

Nicolas Dupré

Melexis, 2022 Bevaix, Switzerland

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 January 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Open access
TSThéo Le Signor
Théo Le Signor
NDNicolas Dupre
Nicolas Dupre
GCGael Close
Gael Close
To enable precise manipulation of fragile objects, robots need the sense of touch. Localized sensing of the 3D force vector with a few mN of resolution is desired. Magnetic force sensors, consisting of a magnet embedded in an elastomer and a 3D magnetometer, were demonstrated as desirable candidates. These prior-art sensors measure the local 3D magnetic field at a single sensing pixel. Hence, they cannot distinguish between the signal and stray magnetic fields. Any stray field directly leaks into the force readout signal path. This letter introduces a design immune to stray magnetic fields. The sensor uses multiple magnetic pixels, and operates on the gradient of the magnetic field. The pixels and conditioning electronics are fully integrated on chip. The 3D force calculation is based on a polynomial model fitted to a calibration data set. The impact of a 2-mT magnetic stray field on the force output is limited to 0.3% of the full scale—about two orders magnitude improvement over the prior art. The force resolution is 2.7 mN and remains competitive. Furthermore, an on-chip temperature sensor and an algorithm are used to compensate the intrinsic thermal drift in the range 0–50 ${}^{\circ }$ C. To validate the proper force regulation in spite of a nearby magnet, we integrated our prototype into a robotic hand. Our results demonstrate the robustness of 3D magnetic force sensors in the presence of real-world parasitic disturbances.

10 March 2023 in Sensors
Verified
Journal Article
Open access
PDF file
TSThéo Le Signor
Théo Le Signor
NDNicolas Dupré
Nicolas Dupré
JDJeroen Didden
Jeroen Didden
ELEugene Lomakin
Eugene Lomakin
GCGael Close
Gael Close
The manipulation of delicate objects remains a key challenge in the development of industrial robotic grippers. Magnetic force sensing solutions, which provide the required sense of touch, have been demonstrated in previous work. The sensors feature a magnet embedded within a deformable elastomer, which is mounted on top of a magnetometer chip. A key drawback of these sensors lies in the manufacturing process, which relies on the manual assembly of the magnet–elastomer transducer, impacting both the repeatability of measurements across sensors and the potential for a cost-effective solution through mass-manufacturing. In this paper, a magnetic force sensor solution is presented with an optimized manufacturing process that will facilitate mass production. The elastomer–magnet transducer was fabricated using injection molding, and the assembly of the transducer unit, on top of the magnetometer chip, was achieved using semiconductor manufacturing techniques. The sensor enables robust differential 3D force sensing within a compact footprint (5 mm × 4.4 mm × 4.6 mm). The measurement repeatability of these sensors was characterized over multiple samples and 300,000 loading cycles. This paper also showcases how the 3D high-speed sensing capabilities of these sensors can enable slip detection in industrial grippers.

13 December 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
SHSamuel Huber
Samuel Huber
JBJan-Willem Burssens
Jan-Willem Burssens
NDNicolas Dupré
Nicolas Dupré
ODOlivier Dubrulle
Olivier Dubrulle
YBYves Bidaux
Yves Bidaux
CSChristian Schott
Christian Schott
Contactless magnetic position sensors are used in countless industrial and automotive applications. However, as a consequence of the electrification trend the sensors can be exposed to parasitic magnetic stray fields, and their desired robustness may be compromised. In this paper we publish for the first time how this challenge is addressed and constructively solved using a complete paradigm change leaving conventional magnetic field measurement behind and entering into the realm of magnetic field gradient measurement. Our novel sensor system consists of an integrated Hall sensor realized in 0.18 μm CMOS technology with magnetic concentrators and a four-pole permanent magnet. The intrinsic angular accuracy was assessed comparing the rotary position of the permanent magnet with the sensor output showing angle errors below 0.3°. Additional end-of-line calibration can be applied using built-in memory and processing capability to further increase the accuracy. Finally, we demonstrate the immunity against stray fields of 4000 A/m which led to errors below 0.1°, corresponding to 0.06% of the sensors fullscale angular range. In conclusion, this novel sensor system offers a compact and flexible solution for stray-field immune rotary position measurement in harsh environment.

10 December 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
NDNicolas Dupré
Nicolas Dupré
ODOlivier Dubrulle
Olivier Dubrulle
SHSamuel Huber
Samuel Huber
JBJan-Willem Burssens
Jan-Willem Burssens
CSChristian Schott
Christian Schott
GCGael Close
Gael Close
This paper experimentally demonstrates the stray-field robustness capability of a novel Hall-based rotary position sensor concept (Huber, S., et al, 2018). The sensor targets safety-related automotive applications, for example powertrain and power steering. In these applications, the safety requirement specifies a maximum stray-field induced error of 0.4°. Therefore, the robustness in corner cases needs to be assessed. We demonstrate the stray-field immunity in multiple corner cases for temperature from −40 °C up to 160 °C and over lifetime. The impact of a uniform 5 mT stray field over all conditions (3σ) is shown to be less than 0.25°. The fully-integrated automotive-qualified sensor is implemented in a 0.18-μm CMOS technology, and achieves 0.7° of angular accuracy.