28 May 2025 in BMC Oral Health
Primary stability is a perquisite for achieving successful osseointegration. Additionally thermal effect of implant bed preparation plays an important role in success of a dental implant. This ex vivo study was conducted to compare one step implant specific osteotomy and conventional osteotomy in terms of primary stability and thermal changes during surgery. Forty eight implants were inserted into the sheep iliac crest bones each with a safe distance to each other and divided into six groups. In two of the groups implant specific osteotomy and in the remaining 4 groups conventional osteotomy was performed. In the groups, the primary stability of the trioval implants designed for the implant specific osteotomy were compared with the oval active threaded implants. The two osteotomy methods were also compared. Additionally the thermal changes during the two osteotomy methods were compared using a double-channel temperature monitoring device. Statistically significant differences (P <.05) were observed between the stability groups and the thermal evaluation groups (P <.05). Implant specific osteotomy revealed significantly higher stability than the conventional osteotomy (P <.001). Osteotomy without irrigation caused significantly higher thermal changes than the conventional osteotomy wit irrigation (P <.001). Although the implant specific osteotomy reveals better primary stability, it causes higher temperature during drilling. However, since this increase is within the limits and doesn’t cause a risk in terms of osseointegration, it may be used safely in clinical practice.
26 July 2025 in BMC Oral Health
AÇAbdulkadir Burak Çankaya
This study evaluated temperature changes at implant preparation sites using a surgical guide, the effects of the cooling solution’s temperature, and the impact of performing osteotomy at low speed without irrigation. The working hypothesis was that effective cooling with a low-temperature solution is essential to prevent excessive heat generation at the osteotomy site. A surgical guide was fabricated using stereolithographic technology. Temperature variations were recorded using a K-type thermocouple. On 40 sheep iliac bone specimens, four implant sites were prepared with a surgical guide as experimental groups: 2.9 mm × 8.5 mm and 2.9 mm × 13 mm representing narrow diameters, and 3.8 mm × 8.5 mm and 3.8 mm × 13 mm representing regular diameters. A 3.5 mm × 10 mm implant site prepared using the conventional method served as the control group. A statistically significant temperature increase was observed in all groups as the bur diameter increased. The temperature rise in implant sites prepared with surgical guides at high speed under irrigation was significantly higher than that observed with the conventional technique. Furthermore, the temperature elevation in the group irrigated with solution cooled to 10 °C was significantly lower than in the group irrigated with solution at 24 °C and the group subjected to low-speed drilling without irrigation. Appropriately applied external irrigation, tailored to patient-specific conditions, can maintain intraosseous temperatures within safe thresholds. Moreover, refraining from low-speed drilling without irrigation and employing low-temperature cooling solutions in guided surgical systems represent more reliable strategies for controlling thermal increases.
16 October 2024 in Journal of Advanced Oral Research
Aim: This study proposes to investigate the influence of various surgical guide designs on the generation temperature in the cortical and cancellous regions of the osteotomy site. The working hypothesis was that open guides are more efficacious in controlling excessive heat generation in cortical and cancellous areas. Materials and Methods: Implant osteotomy was performed on specimens simulating D3 bone density using surgical guides produced with three different designs: an open guide, a guide with an external cooling channel, and a closed guide. Temperature increases occurring in the cortical layer from a depth of 2 mm and in the cancellous layer from a depth of 10 mm were measured with type K thermocouples. Results: Temperature averages recorded from a depth of 2 mm during osteotomy show statistically significant differences between groups ( p = .003). The temperature rise in the group using a closed surgical guide was significantly higher than in the groups using an open surgical guide and a surgical guide with an external cooling channel on the cortical layer, while the temperature increase did not show any significant difference in both cortical and cancellous layers between the open guide and guide with external cooling channel. Temperature averages recorded from a depth of 10 mm do not show statistically significant differences between groups ( p = .054). Conclusion: Using open surgical guides or surgical guides with external cooling channels among the guided surgical systems is a more reliable way to keep the thermal increase under control.
15 January 2025 in Medical Records
Aim: Mandibular angle fractures account for 23-42% of all mandibular fractures, with treatment options often debated due to the region's anatomical complexity. While single miniplate fixation has shown low complication rates, issues like screw loosening remain a challenge. Polymethylmethacrylate (PMMA) has been widely used in orthopedic surgery to improve screw stability. This study aimed to evaluate the effect of PMMA on the stability of loosened screws in mandibular angle fractures. Material and Method: Twenty hemimandibles from sheep cadavers were divided into control and experimental groups. In the control group, standard 2.0 mm screws were inserted without PMMA augmentation. In the experimental group, a 1.6 mm pilot hole was used to simulate screw loosening, and PMMA was injected into the screw tracts before screw insertion. Both groups underwent vertical force testing using a hydraulic device, with displacement values measured at 50 N of force. Statistical analysis was performed using the Student t-test, with significance set at p
1 September 2021 in Medical Records
Removal of an impacted maxillary third molar can be challenging for both dental clinicians and oral surgeons. Frequently encountered complications include infection, pain, swelling, root fractures, trismus, and haemorrhage. In addition, unexpected displacement of the maxillary third molar may be encountered during the extraction process. This case report presents a maxillary third molar displaced to the infratemporal fossa, as well as removal of the tooth following 1 month, along with the causative factors. The roles of orthopantomography and dental volumetric tomography scans in determining the localization of the tooth are discussed, together with different surgical options and risks for surgical removal of the tooth from the infratemporal fossa.