A model is developed for liquid drop impact on a solid surface that captures the thin film gas flow beneath the drop, even when the film’s thickness is below the mean free path in the gas so that gas kinetic effects (GKE) are important. Simulation results agree with experiments, with the impact speed threshold between bouncing and wetting reproduced to within 5%, while a model without GKE overpredicts this value by at least 50%. To isolate GKE, the pressure dependence of the threshold is mapped and provides experimentally verifiable predictions. There are two principal modes of contact leading to wetting and both are associated with a van der Waals driven instability of the film.
The rapid detection of pollutants in water can be performed with enzymatic probes, the catalytic light-emitting activity of which decreases in the presence of many types of pollutants. Herein, we present a microfluidic system for continuous chemoenzymatic biosensing that generates emulsion droplets containing two enzymes of the bacterial bioluminescent system (luciferase and NAD(P)H:FMN–oxidoreductase) with substrates required for the reaction. The developed chip generates “water-in-oil” emulsion droplets with a volume of 0.1 L and a frequency of up to 12 drops per minute as well as provides the efficient mixing of reagents in droplets and their distancing. The bioluminescent signal from each individual droplet was measured by a photomultiplier tube with a signal-to-noise ratio of up to 3000/1. The intensity of the luminescence depended on the concentration of the copper sulfate with the limit of its detection of 5 M. It was shown that bioluminescent enzymatic reactions could be carried out in droplet reactors in dispersed streams. The parameters and limitations required for the bioluminescent reaction to proceed were also studied. Hereby, chemoenzymatic sensing capabilities powered by a droplet microfluidics manipulation technique may serve as the basis for early-warning online water pollution systems.
2 November 2015 in Journal of Physics: Conference Series
Creation and study of specialized nanowhisker probes with magnetic coating are performed for high-precision imaging of various objects by means of atomic force and magnetic force microscopy. Thin layers of Ni and Co are deposited on the surface of nanowhisker structures to perform visualization of magnetic fields on the sample surface, in particular, structure of pits on a hard disk drive (HDD). It is revealed that probes with nanowhisker structures covered with magnetic coating due to their high aspect ratio demonstrate a higher spatial resolution and contrast of magnetic fields visualization in comparison with standard magnetic probes.
The results on making a microfluidic chip for in vitromicroscopic investigations of single cells are presented. Numerical simulation of the motion trajectories of microparticles makes it possible to...
1 August 2016 in Journal of Physics: Conference Series
Dissolution and mixing of flavin mononucleotide (FMN), which activates a luminescent reaction, were considered in various designs of microfluidic chip for pollution analysis of liquid samples. The aim was to determine the velocity mode of fluid flow ensured the uniform distribution of the FMN in the reaction chamber. Simulation of concentration distribution of FMN in various designs of microfluidic chips was conducted. It was shown that the passive mixing techniques based on the constant flow rate didn't provide mixing of FMN in acceptable time (3 seconds). The most efficient mixing was achieved using variable flow rate with a gradually increasing frequency of oscillation.
Early detection of pollutants in wastewater, water coming out of treatment facilities, drinking water, and water for agricultural needs is a challenging problem. Effective water quality monitoring requires development of new methods for express detection of pollutants. Enzymes from bioluminescent bacteria can be used for the development of new express enzyme-based bioassay systems. This work demonstrates, for the first time, a microfluidic chip to generate emulsion droplets containing two enzymes of the bacterial bioluminescent system (luciferase and NAD(P)H:FMN-oxidoreductase) with reaction substrates. The developed chip generated “water-in-oil” emulsion droplets with a volume of 0.1 L and a frequency of up to 12 droplets per second. A portable photomultiplier tube (PMT) was used to measure the bioluminescent signal in each individual droplet; the signal-to-noise ratio was 3000/1. The intensity of luminescence in droplets depended on the concentration of copper ions. The limit of detection (LOD) for copper sulfate was 1 mg/L. We showed that bioluminescent enzymatic reactions can be carried out in droplet reactors that can be applied for online monitoring of water quality. Thus, the suggested method of biological measurements has a good perspective for biosensing in general.