Kaare Severinsen

Kaare Severinsen

Auto-generated profile, based on publicly available information

Kaare Severinsen

Spinal Cord Injury Centre of Western Denmark, Viborg Regional Hospital, 8800 Viborg, Denmark

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
MTMikkel Berg Thøgersen
Mikkel Berg Thøgersen
MMMostafa Mohammadi
Mostafa Mohammadi
MGMuhammad Ahsan Gull
Muhammad Ahsan Gull
Stefan Hein BengtsonStefan Hein Bengtson
Stefan Hein Bengtson
FKFrederik Victor Kobbelgaard
Frederik Victor Kobbelgaard
LSLotte N. S. Andreasen Struijk
Lotte N. S. Andreasen Struijk
This paper presents the EXOTIC- a novel assistive upper limb exoskeleton for individuals with complete functional tetraplegia that provides an unprecedented level of versatility and control. The current literature on exoskeletons mainly focuses on the basic technical aspects of exoskeleton design and control while the context in which these exoskeletons should function is less or not prioritized even though it poses important technical requirements. We considered all sources of design requirements, from the basic technical functions to the real-world practical application. The EXOTIC features: (1) a compact, safe, wheelchair-mountable, easy to don and doff exoskeleton capable of facilitating multiple highly desired activities of daily living for individuals with tetraplegia; (2) a semi-automated computer vision guidance system that can be enabled by the user when relevant; (3) a tongue control interface allowing for full, volitional, and continuous control over all possible motions of the exoskeleton. The EXOTIC was tested on ten able-bodied individuals and three users with tetraplegia caused by spinal cord injury. During the tests the EXOTIC succeeded in fully assisting tasks such as drinking and picking up snacks, even for users with complete functional tetraplegia and the need for a ventilator. The users confirmed the usability of the EXOTIC.

11 September 2015 in Muscle & Nerve
Verified
Journal Article
Closed access
PDF file
KSKaare Severinsen
Kaare Severinsen
UDUlrik Dalgas
Ulrik Dalgas
KOKristian Overgaard
Kristian Overgaard
APAsger R. Pedersen
Asger R. Pedersen
NØNiels Ørtenblad
Niels Ørtenblad
HAHenning Andersen
Henning Andersen

20 June 2022 in Journal of Rehabilitation Medicine
Verified
Journal Article
Open access
KSKaare Severinsen
Kaare Severinsen
KGKurt Grey
Kurt Grey
AJAnne Haase Juhl
Anne Haase Juhl
PSPreben Soerensen
Preben Soerensen
LOLorenz Oppel
Lorenz Oppel
BLBirgit Tine Larsen
Birgit Tine Larsen
Objective: Drop foot is a common impairment following stroke or other causes of central pathology. We report data on patient self-perceived performance, satisfaction with performance, walking ability, and adverse effects after surgical implantation of the ActiGait® drop foot stimulator.Design: Prospective case study with a 12-month follow-up.Subjects: Twenty-one participants with drop foot caused by central nervous system lesion.Methods: The patients’ self-perceived performance and satisfaction with performance were evaluated using the Canadian Occupational Performance Measure (COPM). Walking ability was assessed using a 10-m walk test and a 6-min walk. Nerve conduction of the peroneal nerve was examined in 10 patients.Results: At follow-up, COPM self-percieved performance from 3.2 to 6.7 points, the median increase being 2.8 (interquartile range (IQR) 2.2–5.0), p < 0.001. Likewise, the COPM satisfaction with performance increased from 2.6 to 6.9 points, the median increase being 4.2 (IQR 2.8–5.8), p < 0.001. Walking velocity increased 0.1 m/s from a baseline measurement of 0.73 m/s (95% confidence interval (95% CI) 0.03–0.2), n = 21, p < 0.01, and walking distance increased by 33 m, from a baseline measurement of 236 m (95% CI 15–51), n = 21, p < 0.001.Conclusion: Stimulation of the peroneal nerve by an implantable stimulator increases self-perceived performance, satisfaction with performance, and ambulation in patients with long-lasting drop foot caused by a central nervous system lesion. LAY ABSTRACTDrop foot is a common impairment following stroke or other causes of disease in the nervous system. This study of 21 patients with drop foot caused by various diseases in the central nervous system reports data on patient self-perceived performance, satisfaction with performance, walking ability, and adverse effects after surgical implantation of the ActiGait® peroneal nerve stimulator. The patients’ self-perceived performance and satisfaction with performance were evaluated using the Canadian Occupational Performance Measure. Walking ability was assessed using a 10-m walk test and a 6-min walk test before implantation and at follow-up. At follow-up, patient self-perceived performance, satisfaction with performance, walking velocity, and walking distance increased. No changes in nerve function were demonstrated. In conclusion, implantable peroneal nerve stimulation increases self-perceived performance, satisfaction with performance, and ambulation in patients with long-lasting drop foot caused by central nervous system lesion.

1 January 2014
Verified
Book Chapter
Closed access
PDF file
KSKaare Severinsen
Kaare Severinsen
KGKurt Grey
Kurt Grey
AJAnne Juhl
Anne Juhl
PSPreben Soerensen
Preben Soerensen
LOL. Oppel
L. Oppel
PLP. T. Birgit Larsen
P. T. Birgit Larsen