Selma Iraqi Houssaini

Selma Iraqi Houssaini

Auto-generated profile, based on publicly available information

Selma Iraqi Houssaini

Institute of Multiphase Flows Hamburg University of Technology Eißendorfer Str. 38 21073 Hamburg Germany

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

23 February 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
TMTimo Alexander Merbach
Timo Alexander Merbach
MAMuhammad Adrian
Muhammad Adrian
CWChristoph Wigger
Christoph Wigger
SHSelma Iraqi Houssaini
Selma Iraqi Houssaini
BBBenedict Bayer
Benedict Bayer
Michael SchlueterMichael Schlueter
Michael Schlueter
Triply Periodic Minimal Surface (TPMS) structures have emerged as a new class of porous materials with variable geometries and favourable transport properties, making them promising for reactor internals in chemical engineering. However, experimental data on internal TPMS flow behaviour are still limited. To address this gap, the flow behaviour in additively manufactured TPMS structures is analysed using three-dimensional Magnetic Resonance Imaging (MRI) velocimetry in a large-bore vertical 3 T MRI system, in cylindrical columns of 38 mm diameter and Reynolds numbers between 50 and 300. Three different TPMS geometries are investigated, and consistency between Computational Fluid Dynamics (CFD) simulations and experimentally measured MRI velocity fields is established through cross-validation. The MRI system provides fully three-dimensional velocity fields with a divergence deviation below 6 %. MRI revealed distinct flow features: the Gyroid TPnS exhibited pronounced channelling, while the Schwarz-Diamond TPSf showed merge-split behaviour, achieving a 46 % increase in lateral mixing compared to the Gyroid TPnS structures. Numerical simulations reproduce the flow features and show agreement with the MRI data. The combined methodology demonstrates the suitability of MRI velocimetry for the experimental validation of CFD simulations and establishes a robust foundation for future studies of heat and mass transfer, as well as reactive flow, in structured reactor systems.

9 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MAMuhammad Adrian
Muhammad Adrian
TMTimo Alexander Merbach
Timo Alexander Merbach
ATArtyom Tsanda
Artyom Tsanda
CWChristoph Wigger
Christoph Wigger
SHSelma Iraqi Houssaini
Selma Iraqi Houssaini
Alexander PennAlexander Penn
Alexander Penn
Scale-up of structured reactors strongly influences transport phenomena, yet it remains unclear whether topology-controlled hydrodynamic mechanisms stay dynamically similar across scales. Here, hydrodynamic scale-up in Gyroid-based triply periodic endo-skeleton surface (TPnS) reactors was investigated using Magnetic Resonance Imaging (MRI) and Computational Fluid Dynamics (CFD) in geometries with inner diameters of 38 mm (DN 40) and 100 mm (DN 100), operated at matched hydraulic Reynolds numbers. Scale-up was achieved by increasing reactor diameter while preserving Gyroid unit-cell size and porosity, isolating reactor-scale effects at identical channel-scale geometry. A large-bore vertical 3 T MRI system with custom-built radiofrequency receive arrays enabled non-invasive three-dimensional velocimetry inside opaque structured reactors not only at DN 40 but also at DN 100, to the authors' knowledge the first such measurement at this scale. Velocity fields were validated against theory, mass flow measurements, and CFD. The measurements show that transport enhancement in Gyroid TPnS structures is governed by topology-controlled inertial flow dynamics: interconnected channels generate localized high-velocity pathways, transverse momentum redistribution, and stable counter-rotating secondary-flow structures. Increasing Reynolds number strengthens these vortical motions and enhances transverse transport while preserving the dominant flow topology. These mechanisms are retained during scale-up from DN 40 to DN 100, whereas the relative mean-median difference of the axial velocity remains consistently lower in DN 100 (0.01-0.10) than in DN 40 (0.14-0.27), indicating a more symmetric axial-velocity distribution in the larger reactor. The MRI-CFD methodology provides an experimentally validated framework for investigating transport in structured reactors at industrially relevant scales.

27 November 2024 in Chemical Engineering & Technology
Verified
Journal Article
Open access
DNDaniel Niehaus
Daniel Niehaus
ALAnastasios Lyberis
Anastasios Lyberis
SHSelma Iraqi Houssaini
Selma Iraqi Houssaini
ZPZeynep Perçin
Zeynep Perçin
GLGregor Liebsch
Gregor Liebsch
Michael SchlueterMichael Schlueter
Michael Schlueter
Utilizing pressure as a process parameter can make biotechnological processes more efficient and attractive compared to established ones. This paper presents a high‐pressure reactor setup for enzymatically catalyzed gas–liquid reactions, which can be operated up to 15.0 MPa. The reactor is equipped with optical measurement technology for inline and in situ monitoring of the oxygen concentration under high‐pressure conditions. The setup is characterized by assessing the influence of the process parameter pressure on the conversion of the glucose oxidation to d‐glucono‐δ‐lactone by immobilized glucose oxidase. The study demonstrates that the increased oxygen availability due to higher solubility reduces the reaction time in a batch reactor from 270 to 90 min.