Matteo Fusaglia

Matteo Fusaglia

Auto-generated profile, based on publicly available information

Matteo Fusaglia

Surgical Department, The Netherlands Cancer Institute, Amsterdam, Netherlands

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2020
Verified
Book Chapter
Closed access
BTBart R. Thomson
Bart R. Thomson
JSJasper N. Smit
Jasper N. Smit
OIOleksandra Ivashchenko
Oleksandra Ivashchenko
NKNiels F. M. Kok
Niels F. M. Kok
KKKoert F. D. Kuhlmann
Koert F. D. Kuhlmann
MFMatteo Fusaglia
Matteo Fusaglia

5 July 2021 in Medical Physics
Verified
Journal Article
Open access
PDF file
JSJasper N. Smit
Jasper N. Smit
KKKoert F. D. Kuhlmann
Koert F. D. Kuhlmann
BTBart R. Thomson
Bart R. Thomson
NKNiels F. M. Kok
Niels F. M. Kok
MFMatteo Fusaglia
Matteo Fusaglia
TRTheo J. M. Ruers
Theo J. M. Ruers
Purpose: Registration of pre‐ and intraoperative images is a crucial step of surgical liver navigation, where rigid registration of vessel centerlines is currently commonly used. When using 3D ultrasound (US), accuracy during navigation might be influenced by the size of the intraoperative US volume, yet the relationship between registration accuracy and US volume size is understudied. In this study, we specify an optimal 3D US volume size for registration using varying volumes of liver vasculature. While previous studies measured accuracy at registered fiducials, in this work, accuracy is determined at the target lesion which is clinically the most relevant structure.Methods: Three‐dimensional US volumes were acquired in 14 patients after laparotomy and liver mobilization. Manual segmentation of vasculature and centerline extraction was performed. Intraoperative and preoperative vasculature centerlines were registered with coherent point drift, using different sub‐volumes (sphere with radius r = 30, 40, …, 120 mm). Accuracy was measured by fiducial registration error (FRE) between vessel centerlines and target registration error (TRE) at the center of the target lesion.Results: The lowest FRE for vessel registration was reached with r = 50 mm (6.5 ± 2.5 mm), the highest with r = 120 mm (7.1 ± 2.1 mm). Clinical accuracy at the target lesion, resulted most accurate (TRE = 8.8 ± 5.0 mm) in sub‐volumes with a radius of 50 mm. Smaller US sub‐volumes resulted in lower average TREs when compared to larger US sub‐volumes (Pearson's correlation coefficient R = 0.91, p < 0.001).Conclusion: Our results indicate that there is a linear correlation between US volume size and registration accuracy at the tumor. Volumes with radii of 50 mm around the target lesion yield higher accuracy (p < 0.05) (Trial number IRBd18032, 11 September 2018).

26 May 2026 in Medical Image Analysis
Verified
Journal Article
Open access
PLPeng Liu
Peng Liu
BGBianca Güttner
Bianca Güttner
YSYutong Su
Yutong Su
CLChenyang Li
Chenyang Li
JXJinjing Xu
Jinjing Xu
MPMicha Pfeiffer
Micha Pfeiffer
Non-rigid registration is essential for augmented reality-guided laparoscopic liver surgery, as it enables the fusion of preoperative information such as tumor location and vascular structures into the limited intraoperative view, thereby enhancing surgical navigation. A prerequisite is the accurate prediction of intraoperative liver deformation, which remains highly challenging due to factors such as large deformation caused by pneumoperitoneum, respiration and tool interaction as well as noisy intraoperative data, and limited field of view due to occlusion and constrained camera movement. To address these challenges, we introduce PIVOTS, a Preoperative to Intraoperative VOlume-To-Surface registration neural network that directly takes point clouds as input for deformation prediction. The geometric feature extraction encoder allows multi-resolution feature extraction, and the decoder, comprising inter-modality cross attention modules, enables information exchange between pre- and intraoperative features and accurate multi-level displacement prediction. We train the neural network on a large synthetic dataset created using a biomechanical simulation pipeline that explicitly targets the mentioned intraoperative challenges and validate its performance on both synthetic and real datasets. Results demonstrate superior registration performance of our method compared to baseline methods, exhibiting strong robustness against high amounts of noise, large deformation, and various levels of intraoperative visibility. The network is fast enough to run multiple times per second and directly generalizes to new patients without retraining. We publish training and test sets as evaluation benchmarks in an effort to contribute to the development of more robust liver registration methods based on volume-to-surface data. Code, docker container and datasets are available athttps://github.com/pengliu-nct/PIVOTS.