Paul Wright

Paul Wright

Auto-generated profile, based on publicly available information

Paul Wright

Department of Electrical and Electronic Engineering, The University of Manchester, Manchester, U.K.

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2023 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
ADAltug Didikoglu
Altug Didikoglu
NMNavid Mohammadian
Navid Mohammadian
SJSheena Johnson
Sheena Johnson
MTMartie van Tongeren
Martie van Tongeren
PWPaul Wright
Paul Wright
Robert LucasRobert Lucas
Robert Lucas
Experimental and interventional studies show that light can regulate sleep timing and sleepiness while awake by setting the phase of circadian rhythms and supporting alertness. The extent to which differences in light exposure explain variations in sleep and sleepiness within and between individuals in everyday life remains less clear. Here, we establish a method to address this deficit, incorporating an open-source wearable wrist-worn light logger (SpectraWear) and smartphone-based online data collection. We use it to simultaneously record longitudinal light exposure (in melanopic equivalent daylight illuminance), sleep timing, and subjective alertness over seven days in a convenience sample of 59 UK adults without externally imposed circadian challenge (e.g., shift work or jetlag). Participants reliably had strong daily rhythms in light exposure but frequently were exposed to less light during the daytime and more light in pre-bedtime and sleep episodes than recommended [T. M. Brown et al. , PLoS Biol. 20 , e3001571 (2022)]. Prior light exposure over several hours was associated with lower subjective sleepiness with, in particular, brighter light in the late sleep episode and after wake linked to reduced early morning sleepiness (sleep inertia). Higher pre-bedtime light exposure was associated with longer sleep onset latency. Early sleep timing was correlated with more reproducible and robust daily patterns of light exposure and higher daytime/lower night-time light exposure. Our study establishes a method for collecting longitudinal sleep and health/performance data in everyday life and provides evidence of associations between light exposure and important determinants of sleep health and performance.

17 January 2024 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
NMNavid Mohammadian
Navid Mohammadian
ADAltug Didikoglu
Altug Didikoglu
Christopher BeachChristopher Beach
Christopher Beach
PWPaul Wright
Paul Wright
JMJoshua W. Mouland
Joshua W. Mouland
ACAlexander Casson
Alexander Casson
Light exposure is a vital regulator of physiology and behavior in humans. However, monitoring of light exposure is not included in current wearable Internet of Things (IoT) devices, and only recently have international standards defined $\alpha $ -optic equivalent daylight illuminance (EDI) measures for how the eye responds to light. This article reports a wearable light sensor node that can be incorporated into the IoT to provide monitoring of EDI exposure in real-world settings. We present the system design, electronic performance testing, and accuracy of EDI measurements when compared to a calibrated spectral source. This includes consideration of the directional response of the sensor, and a comparison of performance when placed on different parts of the body, and a demonstration of practical use over 7 days. Our device operates for 3.5 days between charges, with a sampling period of 30 s. It has 10 channels of measurement, over the range 415–910 nm, balancing accuracy and cost considerations. Measured $\alpha $ -opic EDI results for 13 devices show a mean absolute error of less than 0.07 log lx, and a minimum between device correlation of 0.99. These findings demonstrate that accurate light sensing is feasible, including at wrist worn locations. We provide an experimental platform for use in future investigations in real-world light exposure monitoring and IoT-based lighting control.

21 January 2022 in IEEE Sensors Journal
Verified
Journal Article
Open access
TOTaweechai Ouypornkochagorn
Taweechai Ouypornkochagorn
NTNatasa Terzija
Natasa Terzija
PWPaul Wright
Paul Wright
JDJohn L. Davidson
John L. Davidson
NPNick Polydorides
Nick Polydorides
HMHugh McCann
Hugh McCann
An Electrical Impedance Tomography (EIT) system has been developed for dynamic three-dimensional imaging of changes in conductivity distribution in the human head, using scalp-mounted electrodes. We attribute these images to changes in cerebral perfusion. At 100 frames per second (fps), voltage measurement is achieved with full-scale signal-to-noise ratio of 105 dB and common-mode rejection ratio > 90 dB. A novel nonlinear method is presented for 3-D imaging of the difference in conductivity distribution in the head, relative to a reference time. The method achieves much reduced modelling error. It successfully localizes conductivity inclusions in experimental and simulation tests, where previous methods fail. For > 50 human volunteers, the rheoencephalography (REG) waveform is observed in EIT voltage measurements for every volunteer, with peak-to-peak amplitudes up to approx. $50 ~\mu \text{V}_{{\mathrm {rms}}}$ . Images are presented of the change in conductivity distribution during the REG/cardiac cycle, at 50 fps, showing maximum local conductivity change of approx. 1% in grey/white matter. A total of 17 tests were performed during short (typically 5s) carotid artery occlusions on 5 volunteers, monitored by Transcranial Doppler ultrasound. From EIT measurements averaged over complete REG/cardiac cycles, 13 occlusion tests showed consistently decreased conductivity of cerebral regions on the occluded side, and increased conductivity on the opposite side. The maximum local conductivity change during occlusion was approx. 20%. The simplicity of the carotid artery intervention provides a striking validation of the scalp-mounted measurement system in imaging cerebral hemodynamics, and the REG images indicate its unique combination of sensitivity and temporal resolution.

27 October 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YFYalei Fu
Yalei Fu
RZRui Zhang
Rui Zhang
JXJiangnan Xia
Jiangnan Xia
AGAndrew Gough
Andrew Gough
SCStuart Clark
Stuart Clark
CLChang Liu
Chang Liu
Exhaust Gas Temperature (EGT) is a key parameter in diagnosing the health of gas turbine engines (GTEs). In this paper, we propose a model-driven spectroscopic network with strong generalizability to monitor the EGT rapidly and accurately. The proposed network relies on data obtained from a well-proven temperature measurement technique, i.e., wavelength modulation spectroscopy, with the novelty of introducing underlying physical absorption model and building a hybrid dataset from simulation and experiment. This hybrid model-driven network enables strong noise resistance of the neural network against real-world experimental data. The proposed network is assessed by in situ measurements of EGT on an aero-GTE at millisecond-level temporal response. Experimental results indicate that the proposed network substantially outperforms previous neural-network methods in terms of accuracy and precision of the measured EGT when the GTE is steadily loaded.

10 July 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YCYuan Chen
Yuan Chen
JXJiangnan Xia
Jiangnan Xia
RZRui Zhang
Rui Zhang
YXYikai Xia
Yikai Xia
MZMinqiu Zhou
Minqiu Zhou
CLChang Liu
Chang Liu
Laser absorption spectroscopy (LAS) has been widely adopted as a diagnostic tool for reactive flow-field monitoring in industrial combustion applications. In spite of various advancements in LAS signal processing schemes, these harsh environments inevitably impose noise and interference on the LAS measurement data, thus increasing inaccuracy and uncertainty in combustion analysis. This paper proposes a machine learning-enhanced LAS methodology that significantly mitigates noise-induced distortions in absorption spectra, yielding a more accurate representation of the original spectral sequence through continuous measurements. The proposed method is a novel architecture that integrates a Denoising Autoencoder (DAE) with a Long Short-Term Memory (LSTM) network for enhanced LAS signal analysis. Developed entirely using in situ experimental data, this approach ensures strong portability for industrial combustion diagnostics, where multi-source measurement noise is difficult to model or quantify. To validate the proposed method, we conducted a combustion experiment on an Auxiliary Power Unit (APU), a full-scale commercial gas turbine aero-engine, focusing on exhaust temperature measurements using our advanced LAS technique. The experimental results demonstrate the efficacy of the proposed method in recovering high-fidelity absorption spectra from the noise-contaminated data, enabling more convenient, accurate and stable APU exhaust temperature measurements with a standard deviation below 7.9 °C. This indicates its significant potential in industrial combustion diagnostics, offering a reliable tool for precise analysis and assessment in harsh environments.