Christopher Beach

Dr. Christopher Beach

The University of Manchester
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 October 2017 in Journal of Materials Chemistry C
Verified
Journal Article
Open access
PDF file
NKNazmul Karim
Nazmul Karim
SAShaila Afroj
Shaila Afroj
AMAndromachi Malandraki
Andromachi Malandraki
SBSean Butterworth
Sean Butterworth
Christopher BeachChristopher Beach
Christopher Beach
SYStephen G. Yeates
Stephen G. Yeates
Inkjet printing of graphene inks is considered to be very promising for wearable e-textile applications as benefits of both inkjet printing and extra-ordinary electronic, optical and mechanical properties of graphene can be exploited. However, the common problem associated with inkjet printing of conductive inks on textiles is the difficulty to print a continuous conductive path on a rough and porous textile surface. Here we report inkjet printing of an organic nanoparticle based surface pre-treatment onto textiles to enable all inkjet-printed graphene e-textiles for the first time. The functionalized organic nanoparticles present a hydrophobic breathable coating on textiles. Subsequent inkjet printing of a continuous conductive electrical path onto the pre-treated coating reduced the sheet resistance of graphene-based printed e-textiles by three orders of magnitude from 1.09 × 106 Ω sq−1 to 2.14 × 103 Ω sq−1 compared with untreated textiles. We present several examples of how this finding opens up opportunities for real world applications of printed, low cost and environmentally friendly graphene wearable e-textiles.

10 August 2018 in IEEE Access
Verified
Journal Article
Open access
Christopher BeachChristopher Beach
Christopher Beach
SKSammy Krachunov
Sammy Krachunov
JPJames Pope
James Pope
Xenofon FafoutisXenofon Fafoutis
Xenofon Fafoutis
RPRobert J. Piechocki
Robert J. Piechocki
ACAlexander J. Casson
Alexander J. Casson
Cardiovascular diseases are the leading cause of death in the U.K., motivating the use of long term wearable devices to monitor the heart in out-of-the-clinic settings. While a wide number of heart rate measuring wearable devices are now available, they are principally based upon photoplethysmography rather than the electrocardiogram (ECG) and are stand-alone devices rather than integrated with Internet-of-Things infrastructures which collect and combine information from a wide range of sensors. This paper presents a wrist worn ECG sensor which integrates with the SPHERE IoT platform—the UK’s demonstrator platform for health monitoring in the home environment, combining a range of on-person and ambient sensors. The ECG device integrates ultralow power consumption electronics with personalizable 3-D printed casings which maintain gold standard Ag/AgCl electrodes to provide measurements of the raw ECG waveform, heart rate, and meanNN and SDNN heart rate variability parameters. The end device allows for more than a month of battery life for a weight of <50 g including the watch straps. The design and heart sensing performance of the device are presented in detail, together with the integration with the SPHERE IoT platform.

6 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
AVAndrei Velcescu
Andrei Velcescu
ALAlexander Lindley
Alexander Lindley
CCCiro Cursio
Ciro Cursio
SKSammy Krachunov
Sammy Krachunov
Christopher BeachChristopher Beach
Christopher Beach
ACAlexander Casson
Alexander Casson
For electroencephalography (EEG) in haired regions of the head, finger-based electrodes have been proposed in order to part the hair and make a direct contact with the scalp. Previous work has demonstrated 3D-printed fingered electrodes to allow personalisation and different configurations of electrodes to be used for different people or for different parts of the head. This paper presents flexible 3D-printed EEG electrodes for the first time. A flexible 3D printing element is now used, with three different base mechanical structures giving differently-shaped electrodes. To obtain improved sensing performance, the silver coatings used previously have been replaced with a silver/silver-chloride coating. This results in reduced electrode contact impedance and reduced contact noise. Detailed electro-mechanical testing is presented to demonstrate the performance of the operation of the new electrodes, particularly with regards to changes in conductivity under compression, together with on-person tests to demonstrate the recording of EEG signals.

2 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Christopher BeachChristopher Beach
Christopher Beach
Glen CooperGlen Cooper
Glen Cooper
Andrew Patrick Hayes WeightmanAndrew Patrick Hayes Weightman
Andrew Patrick Hayes Weightman
EHEmma F. Hodson-Tole
Emma F. Hodson-Tole
NRNeil D Reeves
Neil D Reeves
ACAlexander Casson
Alexander Casson
Diabetic foot ulcers (DFUs) are a life-changing complication of diabetes that can lead to amputation. There is increasing evidence that long-term management with wearables can reduce incidence and recurrence of this condition. Temperature asymmetry measurements can alert to DFU development, but measurements of dynamic information, such as rate of temperature change, are under investigated. We present a new wearable device for temperature monitoring at the foot that is personalised to account for anatomical variations at the foot. We validate this device on 13 participants with diabetes (no neuropathy) (group name D) and 12 control participants (group name C), during sitting and standing. We extract dynamic temperature parameters from four sites on each foot to compare the rate of temperature change. During sitting the time constant of temperature rise after shoe donning was significantly (p < 0.05) faster at the hallux (p = 0.032, 370.4 s (C), 279.1 s (D)) and 5th metatarsal head (p = 0.011, 481.9 s (C), 356.6 s (D)) in participants with diabetes compared to controls. No significant differences at the other sites or during standing were identified. These results suggest that temperature rise time is faster at parts of the foot in those who have developed diabetes. Elevated temperatures are known to be a risk factor of DFUs and measurement of time constants may provide information on their development. This work suggests that temperature rise time measured at the plantar surface may be an indicative biomarker for differences in soft tissue biomechanics and vascularisation during diabetes onset and progression.

24 June 2021 in Healthcare Technology Letters
Verified
Journal Article
Open access
PDF file
Christopher BeachChristopher Beach
Christopher Beach
MLMingjie Li
Mingjie Li
EBErtan Balaban
Ertan Balaban
ACAlexander Casson
Alexander Casson
This paper presents a new active electrode design for electroencephalogram (EEG) and electrocardiogram (ECG) sensors based on inertial measurement units to remove motion artefacts during signal acquisition. Rather than measuring motion data from a single source for the entire recording unit, inertial measurement units are attached to each individual EEG or ECG electrode to collect local movement data. This data is then used to remove the motion artefact by using normalised least mean square adaptive filtering. Results show that the proposed active electrode design can reduce motion contamination from EEG and ECG signals in chest movement and head swinging motion scenarios. However, it is found that the performance varies, necessitating the need for the algorithm to be paired with more sophisticated signal processing to identify scenarios where it is beneficial in terms of improving signal quality. The new instrumentation hardware allows data driven artefact removal to be performed, providing a new data driven approach compared to widely used blind‐source separation methods, and helps enable in the wild EEG recordings to be performed.

17 January 2024 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
NMNavid Mohammadian
Navid Mohammadian
ADAltug Didikoglu
Altug Didikoglu
Christopher BeachChristopher Beach
Christopher Beach
PWPaul Wright
Paul Wright
JMJoshua W. Mouland
Joshua W. Mouland
ACAlexander Casson
Alexander Casson
Light exposure is a vital regulator of physiology and behavior in humans. However, monitoring of light exposure is not included in current wearable Internet of Things (IoT) devices, and only recently have international standards defined $\alpha $ -optic equivalent daylight illuminance (EDI) measures for how the eye responds to light. This article reports a wearable light sensor node that can be incorporated into the IoT to provide monitoring of EDI exposure in real-world settings. We present the system design, electronic performance testing, and accuracy of EDI measurements when compared to a calibrated spectral source. This includes consideration of the directional response of the sensor, and a comparison of performance when placed on different parts of the body, and a demonstration of practical use over 7 days. Our device operates for 3.5 days between charges, with a sampling period of 30 s. It has 10 channels of measurement, over the range 415–910 nm, balancing accuracy and cost considerations. Measured $\alpha $ -opic EDI results for 13 devices show a mean absolute error of less than 0.07 log lx, and a minimum between device correlation of 0.99. These findings demonstrate that accurate light sensing is feasible, including at wrist worn locations. We provide an experimental platform for use in future investigations in real-world light exposure monitoring and IoT-based lighting control.