9 October 2023 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
ADAltug Didikoglu
Altug Didikoglu
NMNavid Mohammadian
Navid Mohammadian
SJSheena Johnson
Sheena Johnson
MTMartie van Tongeren
Martie van Tongeren
PWPaul Wright
Paul Wright
Robert LucasRobert Lucas
Robert Lucas
Experimental and interventional studies show that light can regulate sleep timing and sleepiness while awake by setting the phase of circadian rhythms and supporting alertness. The extent to which differences in light exposure explain variations in sleep and sleepiness within and between individuals in everyday life remains less clear. Here, we establish a method to address this deficit, incorporating an open-source wearable wrist-worn light logger (SpectraWear) and smartphone-based online data collection. We use it to simultaneously record longitudinal light exposure (in melanopic equivalent daylight illuminance), sleep timing, and subjective alertness over seven days in a convenience sample of 59 UK adults without externally imposed circadian challenge (e.g., shift work or jetlag). Participants reliably had strong daily rhythms in light exposure but frequently were exposed to less light during the daytime and more light in pre-bedtime and sleep episodes than recommended [T. M. Brown et al. , PLoS Biol. 20 , e3001571 (2022)]. Prior light exposure over several hours was associated with lower subjective sleepiness with, in particular, brighter light in the late sleep episode and after wake linked to reduced early morning sleepiness (sleep inertia). Higher pre-bedtime light exposure was associated with longer sleep onset latency. Early sleep timing was correlated with more reproducible and robust daily patterns of light exposure and higher daytime/lower night-time light exposure. Our study establishes a method for collecting longitudinal sleep and health/performance data in everyday life and provides evidence of associations between light exposure and important determinants of sleep health and performance.

22 July 2019 in Chronobiology International
Verified
Journal Article
Closed access
ADAltug Didikoglu
Altug Didikoglu
AMAsri Maharani
Asri Maharani
APAntony Payton
Antony Payton
NPNeil Pendleton
Neil Pendleton
MCMaria Mercè Canal
Maria Mercè Canal
Evening-oriented sleep timing preferences have been associated with risk of diabetes, cardiovascular diseases, obesity, psychiatric disorders, and increased mortality. This research aims to explore the relationship between diurnal preferences (chronotype), daily habits, metabolic health, and mortality, using longitudinal data from The University of Manchester Longitudinal Study of Cognition in Normal Healthy Old Age (6375 participants at inception, recruited in the North of England) with a long follow-up period (up to 35.5 years). Mixed models were used to investigate the influence of aging, socio-demographic, and seasonal factors on sleep timing. Results show that sleep timing shifted towards earlier time with aging. Test seasons influence chronotype of older adults but working schedules challenge seasonality of sleep timing. Moreover, the season of birth may set chronotype in adulthood. Individual chronotype trajectories were clustered using latent class analysis and analyzed against metabolic health and mortality. We observed a higher risk of hypertension in the evening-type cluster compared to morning-type individuals (Odds ratio = 1.88, 95%CI = 1.02/3.47, p = .04). Evening-type cluster was also associated with traits related to lower health such as reduced sport participation, increased risk of depression and psychoticism personality, late eating, and increased smoking and alcohol usage. Finally, Cox regression of proportional hazards was used to study the effects of chronotype on longevity after adjusting for sleep duration, age, gender, smoking, alcohol usage, general health, and social class. The survival analysis (82.6% censored by death) revealed that evening-type chronotype increased the likelihood of mortality (Hazard ratio = 1.15, 95%CI = 1.04/1.26, p = .005). Taken together, chronotype is influenced by aging and seasonal effects. Evening-type preference may have detrimental outcomes for human well-being and longevity.

16 July 2019 in Journal of Sleep Research
Verified
Journal Article
Open access
PDF file
ADAltug Didikoglu
Altug Didikoglu
AMAsri Maharani
Asri Maharani
GTGindo Tampubolon
Gindo Tampubolon
MCMaria Mercè Canal
Maria Mercè Canal
APAntony Payton
Antony Payton
NPNeil Pendleton
Neil Pendleton
The relationships between older age and sleep efficiency have traditionally been assessed using cross‐sectional studies that ignore changes within individuals as they age. This research examines the determinants of sleep efficiency, the heterogeneity in an individual's sleep efficiency trajectory across a period of up to 27 years in later life and its associations with health. The University of Manchester Longitudinal Study of Cognition in Normal Healthy Old Age cohort (n = 6,375; age 42–94 years) was used in this study. Depression and health data were collected using self‐report validated instruments (Cornell Medical Index, Beck Depression Inventory and Geriatric Depression Scale). Longitudinal sleep and sociodemographic data were collected using a study‐specific self‐report questionnaire. A mixed‐effect model was performed for sleep efficiency with adjustments for time‐invariant and time‐variant predictors. Latent class analysis was used to demonstrate subgroups of sleep efficiency trajectories and associations between sleep efficiency clusters and health history of the participants were investigated. Older adults have decreased sleep efficiency over time, with 18.6% decline between 40 and 100 years of age. Three sleep efficiency trajectory clusters were identified: high (32%), medium (50%) and low sleep efficiency (18%). Belonging to the high sleep efficiency cluster was associated with having lower prevalence of hypertension, circulatory problems, general arthritis, breathing problems and recurrent episodes of depression compared to the low efficiency cluster. Overall, ageing decreases sleep efficiency. However, there are detectable subgroups of sleep efficiency that are related to prevalence of different diseases.

22 February 2025 in Building and Environment
Verified
Journal Article
Open access
JDJuliette van Duijnhoven
Juliette van Duijnhoven
SHS.L. Hartmeyer
S.L. Hartmeyer
ADAltug Didikoglu
Altug Didikoglu
OSOliver Stefani
Oliver Stefani
KHK.W. Houser
K.W. Houser
MSM. Spitschan
M. Spitschan

17 January 2024 in IEEE Internet of Things Journal
Verified
Journal Article
Closed access
NMNavid Mohammadian
Navid Mohammadian
ADAltug Didikoglu
Altug Didikoglu
Christopher BeachChristopher Beach
Christopher Beach
PWPaul Wright
Paul Wright
JMJoshua W. Mouland
Joshua W. Mouland
ACAlexander Casson
Alexander Casson
Light exposure is a vital regulator of physiology and behavior in humans. However, monitoring of light exposure is not included in current wearable Internet of Things (IoT) devices, and only recently have international standards defined $\alpha $ -optic equivalent daylight illuminance (EDI) measures for how the eye responds to light. This article reports a wearable light sensor node that can be incorporated into the IoT to provide monitoring of EDI exposure in real-world settings. We present the system design, electronic performance testing, and accuracy of EDI measurements when compared to a calibrated spectral source. This includes consideration of the directional response of the sensor, and a comparison of performance when placed on different parts of the body, and a demonstration of practical use over 7 days. Our device operates for 3.5 days between charges, with a sampling period of 30 s. It has 10 channels of measurement, over the range 415–910 nm, balancing accuracy and cost considerations. Measured $\alpha $ -opic EDI results for 13 devices show a mean absolute error of less than 0.07 log lx, and a minimum between device correlation of 0.99. These findings demonstrate that accurate light sensing is feasible, including at wrist worn locations. We provide an experimental platform for use in future investigations in real-world light exposure monitoring and IoT-based lighting control.

11 December 2024 in Energy and Buildings
Verified
Journal Article
Closed access
MÇMeriç Çelik
Meriç Çelik
ADAltug Didikoglu
Altug Didikoglu
TKTuğçe Kazanasmaz
Tuğçe Kazanasmaz