Constance A. Owens

Constance A. Owens

Auto-generated profile, based on publicly available information

Constance A. Owens

Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, United States of America

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 October 2018 in PLOS ONE
Verified
Journal Article
Open access
PDF file
COConstance A Owens
Constance A Owens
CPChristine Peterson
Christine Peterson
CTChad Tang
Chad Tang
EKEugene J Koay
Eugene J Koay
WYWen Yu
Wen Yu
Jinzhong YangJinzhong Yang
Jinzhong Yang
To evaluate the uncertainty of radiomics features from contrast-enhanced breath-hold helical CT scans of non-small cell lung cancer for both manual and semi-automatic segmentation due to intra-observer, inter-observer, and inter-software reliability. Three radiation oncologists manually delineated lung tumors twice from 10 CT scans using two software tools (3D-Slicer and MIM Maestro). Additionally, three observers without formal clinical training were instructed to use two semi-automatic segmentation tools, Lesion Sizing Toolkit (LSTK) and GrowCut, to delineate the same tumor volumes. The accuracy of the semi-automatic contours was assessed by comparison with physician manual contours using Dice similarity coefficients and Hausdorff distances. Eighty-three radiomics features were calculated for each delineated tumor contour. Informative features were identified based on their dynamic range and correlation to other features. Feature reliability was then evaluated using intra-class correlation coefficients (ICC). Feature range was used to evaluate the uncertainty of the segmentation methods. From the initial set of 83 features, 40 radiomics features were found to be informative, and these 40 features were used in the subsequent analyses. For both intra-observer and inter-observer reliability, LSTK had higher reliability than GrowCut and the two manual segmentation tools. All observers achieved consistently high ICC values when using LSTK, but the ICC value varied greatly for each observer when using GrowCut and the manual segmentation tools. For inter-software reliability, features were not reproducible across the software tools for either manual or semi-automatic segmentation methods. Additionally, no feature category was found to be more reproducible than another feature category. Feature ranges of LSTK contours were smaller than those of manual contours for all features. Radiomics features extracted from LSTK contours were highly reliable across and among observers. With semi-automatic segmentation tools, observers without formal clinical training were comparable to physicians in evaluating tumor segmentation.

9 September 2014 in European Journal of Physics
Verified
Journal Article
Closed access
GBGardo Blado
Gardo Blado
COConstance Owens
Constance Owens
VMVincent Meyers
Vincent Meyers

1 October 2018 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
KKKelly D. Kisling
Kelly D. Kisling
RGRachel B. Ger
Rachel B. Ger
TNTucker J. Netherton
Tucker J. Netherton
CCCarlos E. Cardenas
Carlos E. Cardenas
COConstance A. Owens
Constance A. Owens
SDScott Dube
Scott Dube
A large number of surveys have been sent to the medical physics community addressing many clinical topics for which the medical physicist is, or may be, responsible. Each survey provides an insight into clinical practice relevant to the medical physics community. The goal of this study was to create a summary of these surveys giving a snapshot of clinical practice patterns. Surveys used in this study were created using SurveyMonkey and distributed between February 6, 2013 and January 2, 2018 via the MEDPHYS and MEDDOS listserv groups. The format of the surveys included questions that were multiple choice and free response. Surveys were included in this analysis if they met the following criteria: more than 20 responses, relevant to radiation therapy physics practice, not single‐vendor specific, and formatted as multiple‐choice questions (i.e., not exclusively free‐text responses). Although the results of free response questions were not explicitly reported, they were carefully reviewed, and the responses were considered in the discussion of each topic. Two‐hundred and fifty‐two surveys were available, of which 139 passed the inclusion criteria. The mean number of questions per survey was 4. The mean number of respondents per survey was 63. Summaries were made for the following topics: simulation, treatment planning, electron treatments, linac commissioning and quality assurance, setup and treatment verification, IMRT and VMAT treatments, SRS/SBRT, breast treatments, prostate treatments, brachytherapy, TBI, facial lesion treatments, clinical workflow, and after‐hours/emergent treatments. We have provided a coherent overview of medical physics practice according to surveys conducted over the last 5 yr, which will be instructive for medical physicists.

1 February 2015 in Journal of Luminescence
Verified
Journal Article
Closed access
RFRoss S. Fontenot
Ross S. Fontenot
KBKamala N. Bhat
Kamala N. Bhat
COConstance A. Owens
Constance A. Owens
WHWilliam A. Hollerman
William A. Hollerman
MAMohan D. Aggarwal
Mohan D. Aggarwal

29 September 2020 in Biomedical Physics & Engineering Express
Verified
Journal Article
Open access
AGAashish C Gupta
Aashish C Gupta
SSSuman Shrestha
Suman Shrestha
COConstance A Owens
Constance A Owens
SSSusan A Smith
Susan A Smith
YQYing Qiao
Ying Qiao
RHRebecca M Howell
Rebecca M Howell
Purpose: We previously developed an age-scalable 3D computational phantom that has been widely used for retrospective whole-body dose reconstructions of conventional two-dimensional historic radiation therapy (RT) treatments in late effects studies of childhood cancer survivors. This phantom is modeled in the FORTRAN programming language and is not readily applicable for dose reconstructions for survivors treated with contemporary RT whose treatment plans were designed using computed tomography images and complex treatment fields. The goal of this work was to adapt the current FORTRAN model of our age-scalable computational phantom into Digital Imaging and Communications in Medicine (DICOM) standard so that it can be used with any treatment planning system (TPS) to reconstruct contemporary RT. Additionally, we report a detailed description of the phantom’s age-based scaling functions, information that was not previously published. Method: We developed a Python script that adapts our phantom model from FORTRAN to DICOM. To validate the conversion, we compared geometric parameters for the phantom modeled in FORTRAN and DICOM scaled to ages 1 month, 6 months, 1, 2, 3, 5, 8, 10, 15, and 18 years. Specifically, we calculated the percent differences between the corner points and volume of each body region and the normalized mean square distance (NMSD) between each of the organs. In addition, we also calculated the percent difference between the heights of our DICOM age-scaled phantom and the heights (50th percentile) reported by the World Health Organization (WHO) and Centers for Disease Control and Prevention (CDC) for male and female children of the same ages. Additionally, we calculated the difference between the organ masses for our DICOM phantom and the organ masses for two reference phantoms (from International Comission on Radiation Protection (ICRP) 89 and the University of Florida/National Cancer Institute reference hybrid voxel phantoms) for ages newborn, 1, 5, 10, 15 and adult. Lastly, we conducted a feasibility study using our DICOM phantom for organ dose calculations in a commercial TPS. Specifically, we simulated a 6 MV photon right-sided flank field RT plan for our DICOM phantom scaled to age 3.9 years; treatment field parameters and age were typical of a Wilms tumor RT treatment in the Childhood Cancer Survivor Study. For comparison, the same treatment was simulated using our in-house dose calculation system with our FORTRAN phantom. The percent differences (between FORTRAN and DICOM) in mean dose and percent of volume receiving dose ≥5 Gy were calculated for two organs at risk, liver and pancreas. Results: The percent differences in corner points and the volumes of head, neck, and trunk body regions between our phantom modeled in FORTRAN and DICOM agreed within 3%. For all of the ages, the NMSDs were negliglible with a maximum NMSD of 7.80 × 10 − 2 mm for occiptital lobe of 1 month. The heights of our age-scaled phantom agreed with WHO/CDC data within 7% from infant to adult, and within 2% agreement for ages 5 years and older. We observed that organ masses in our phantom are less than the organ masses for other reference phantoms. Dose calculations done with our in-house calculation system (with FORTRAN phantom) and commercial TPS (with DICOM phantom) agreed within 7%. Conclusion: We successfully adapted our phantom model from the FORTRAN language to DICOM standard and validated its geometric consistency. We also demonstrated that our phantom model is representative of population height data for infant to adult, but that the organ masses are smaller than in other reference phantoms and need further refinement. Our age-scalable computational phantom modeled in DICOM standard can be scaled to any age at RT and used within a commercial TPS to retrospectively reconstruct doses from contemporary RT in childhood cancer survivors.

6 June 2017 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
PDF file
ARAshley E. Rubinstein
Ashley E. Rubinstein
WIW. Scott Ingram
W. Scott Ingram
BABrian Mark Anderson
Brian Mark Anderson
SGSkylar Gay
Skylar Gay
XFXenia J. Fave
Xenia J. Fave
CCCarlos E. Cardenas
Carlos E. Cardenas
To investigate the inter‐ and intra‐fraction motion associated with the use of a low‐cost tape immobilization technique as an alternative to thermoplastic immobilization masks for whole‐brain treatments. The results of this study may be of interest to clinical staff with severely limited resources (e.g., in low‐income countries) and also when treating patients who cannot tolerate standard immobilization masks. Setup reproducibility of eight healthy volunteers was assessed for two different immobilization techniques. (a) One strip of tape was placed across the volunteer's forehead and attached to the sides of the treatment table. (b) A second strip was added to the first, under the chin, and secured to the table above the volunteer's head. After initial positioning, anterior and lateral photographs were acquired. Volunteers were positioned five times with each technique to allow calculation of inter‐fraction reproducibility measurements. To estimate intra‐fraction reproducibility, 5‐minute anterior and lateral videos were taken for each technique per volunteer. An in‐house software was used to analyze the photos and videos to assess setup reproducibility. The maximum intra‐fraction displacement for all volunteers was 2.8 mm. Intra‐fraction motion increased with time on table. The maximum inter‐fraction range of positions for all volunteers was 5.4 mm. The magnitude of inter‐fraction and intra‐fraction motion found using the “1‐strip” and “2‐strip” tape immobilization techniques was comparable to motion restrictions provided by a thermoplastic mask for whole‐brain radiotherapy. The results suggest that tape‐based immobilization techniques represent an economical and useful alternative to the thermoplastic mask.