1 January 2019 in Journal of Korean Medical Science
Lee Y, et al. J Korean Med Sci. 2019 Jan;34(4):e24. https://doi.org/10.3346/jkms.2019.34.e24
20 July 2022 in Journal of Neural Engineering
Objective . This paper presents a conventional light emitting diode (LED) and polymer waveguide coupled silicon optrode array. Approach . Unique lens design at the waveguide inlet enables a high light coupling efficiency with a single LED light source, and provides small power consumption compatible with a wireless optogenetic neuromodulation system. To increase the light intensity at the waveguide tip, a lensed waveguide is fabricated with epoxy-based photoresist SU-8, which has a plano-convex lens shape at the waveguide inlet to focus the light in the horizontal direction. In addition, a cylindrical lens is assembled in front of the waveguide inlet to focus the source light in the vertical direction. Main results . The glass cylindrical lens and SU-8 plano-convex lens increased the light coupling efficiency by 6.7 dB and 6.6 dB, respectively. The fabricated 1 × 4 array of optrodes is assembled with a single LED with 465 nm wavelength, which produces a light intensity of approximately 2.7 mW mm −2 at the SU-8 waveguide outlet when 50 mA input current is applied to the LED. Each optrode has four recording electrodes at the SU-8 waveguide outlet. The average impedance of the iridium oxide (IrO
x
) electroplated recording electrodes is 43.6 kΩ. Significance . In-vivo experiment at the hippocampus region CA1 and CA2 demonstrated the capability of optical stimulation and neural signal recording through the LED and SU-8 waveguide coupled silicon optrode array.
11 August 2022 in Biomedical Engineering Letters
30 August 2015 in Journal of Biomedical Engineering Research
Development of Real-time Closed-loop Neurostimulation System for Epileptic Seizure Suppression neural recording;neurostimulation;epilepsy;closed-loop;real-time; Epilepsy is a chronic neurological disease which produces repeated seizures. Over 30% of epileptic patients cannot be treated with anti-epileptic drugs, and surgical resection may cause loss of brain functions. Seizure suppression by electrical stimulation is currently being investigated as a new treatment method as clinical evidence has shown that electrical stimulation to brain could suppress seizure activity. In this paper, design of a real-time closed-loop neurostimulation system for epileptic seizure suppression is presented. The system records neural signals, detects seizures and delivers electrical stimulation. The system consists of a 6-channel electrode, front-end amplifiers, a data acquisition board by National Instruments, and a neurostimulator and Generic Osorio-Frei algorithm was applied for seizure detection. The algorithm was verified through simulation using electroencephalogram data, and the operation of whole system was verified through simulation and in- vivo test.