20 July 2022 in Journal of Neural Engineering
Objective . This paper presents a conventional light emitting diode (LED) and polymer waveguide coupled silicon optrode array. Approach . Unique lens design at the waveguide inlet enables a high light coupling efficiency with a single LED light source, and provides small power consumption compatible with a wireless optogenetic neuromodulation system. To increase the light intensity at the waveguide tip, a lensed waveguide is fabricated with epoxy-based photoresist SU-8, which has a plano-convex lens shape at the waveguide inlet to focus the light in the horizontal direction. In addition, a cylindrical lens is assembled in front of the waveguide inlet to focus the source light in the vertical direction. Main results . The glass cylindrical lens and SU-8 plano-convex lens increased the light coupling efficiency by 6.7 dB and 6.6 dB, respectively. The fabricated 1 × 4 array of optrodes is assembled with a single LED with 465 nm wavelength, which produces a light intensity of approximately 2.7 mW mm −2 at the SU-8 waveguide outlet when 50 mA input current is applied to the LED. Each optrode has four recording electrodes at the SU-8 waveguide outlet. The average impedance of the iridium oxide (IrO
x
) electroplated recording electrodes is 43.6 kΩ. Significance . In-vivo experiment at the hippocampus region CA1 and CA2 demonstrated the capability of optical stimulation and neural signal recording through the LED and SU-8 waveguide coupled silicon optrode array.
11 August 2022 in Biomedical Engineering Letters
2 September 2023 in Biomedical Engineering Letters
27 July 2026 in Biomedical Engineering Letters
Retinal prosthetic systems have emerged as a promising technology for restoring partial vision in patients with severe photoreceptor degeneration. Over the past two decades, development in epiretinal, subretinal, and suprachoroidal devices has progressed substantially, with several representative platforms demonstrating the feasibility of restoring light perception, object localization, motion discrimination, and limited-form vision in clinical settings. Despite these advances, the visual acuity achieved by existing retinal prostheses remains markedly lower than predictions based on device geometry alone. Particularly, a persistent gap exists between the theoretical spatial resolution implied by electrode or pixel spacing and clinically reported visual performance. This review examines the major factors limiting effective spatial resolution in retinal prosthetic systems, with particular emphasis on the resolution gap. Collectively, available evidence indicates that while electrode spacing may be considered a critical determinant of theoretical resolution, it does not represent a direct surrogate for clinical visual acuity. Consequently, improving prosthetic vision requires denser arrays alongside selective neural recruitment, more stable electrode-retina coupling, and stimulation strategies that optimize functionally meaningful percepts. Elucidating the resolution gap and its underlying determinants will be essential for developing next-generation retinal prosthetic systems that provide more effective visual restoration.