Julien Mekki

Julien Mekki

Auto-generated profile, based on publicly available information

Julien Mekki

Centre National dEtudes Spatiales (CNES), Toulouse, France

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
AMAdriana Morana
Adriana Morana
CCC. Campanella
C. Campanella
EMEmmanuel Marin
Emmanuel Marin
GMG. Melin
G. Melin
TRThierry Robin
Thierry Robin
Sylvain GirardSylvain Girard
Sylvain Girard
Point or distributed optical fiber (OF)-based dosimeters can exploit the observed linear dependence of the radiation-induced attenuation (RIA) at 1550 nm in phosphosilicate OFs to monitor the total ionizing dose (TID). The temperature dependence of the radiation sensitivity coefficients at 1550 nm (expressed in dB km -1 Gy -1 ) of three phosphorus-doped single-mode OFs has been investigated between -80 °C and 300 °C for TID ranging from 1 Gy to 1 kGy(SiO 2 ). Our measurements reveal the same temperature dependence of the calibration factor for the three fibers at the higher temperatures (>120 °C) where the P1 defects, at the origin of the IR-RIA, are metastable. However, the uncertainties on the TID measurements through the fiber-based dosimeter remain within the 15% for temperatures ranging from -80 °C to 120 °C for the three tested fibers. The independence of the RIA and then of the dose measurements from the dose rate is also maintained in this temperature range.

22 February 2021 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Open access
ACAndrea Coronetti
Andrea Coronetti
RARuben Garcia Alia
Ruben Garcia Alia
JBJan Budroweit
Jan Budroweit
TRTomasz Rajkowski
Tomasz Rajkowski
ILIsrael Da Costa Lopes
Israel Da Costa Lopes
RGrosine Coq Germanicus
rosine Coq Germanicus
Functional verification schemes at a level different from component-level testing are emerging as a cost-effective tool for those space systems for which the risk associated with a lower level of assurance can be accepted. Despite the promising potential, system-level radiation testing can be applied to the functional verification of systems under restricted intrinsic boundaries. Most of them are related to the use of hadrons as opposed to heavy ions. Hadrons are preferred for the irradiation of any bulky system, in general, because of their deeper penetration capabilities. General guidelines about the test preparation and procedure for a high-level radiation test are provided to allow understanding which information can be extracted from these kinds of functional verification schemes in order to compare them with the reliability and availability requirements. The use of a general scaling factor for the observed high-level cross sections allows converting test cross sections into orbit rates.

12 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Sylvain GirardSylvain Girard
Sylvain Girard
AMAdriana Morana
Adriana Morana
CHCornelia Hoehr
Cornelia Hoehr
MTMichael Trinczek
Michael Trinczek
JVJeoffray Vidalot
Jeoffray Vidalot
EBEwart Blackmore
Ewart Blackmore
The potential of fiber-based sensors to monitor the fluence of atmospheric neutrons is evaluated through accelerated tests at the TRIUMF Neutron Facility (TNF) (BC, Canada), offering a flux approximatively 109 higher than the reference spectrum observed under standard conditions in New York City, USA. The radiation-induced attenuation (RIA) at 1625 nm of a phosphorus-doped radiation sensitive optical fiber is shown to linearly increase with neutron fluence, allowing an in situ and easy monitoring of the neutron flux and fluence at this facility. Furthermore, our experiments show that the fiber response remains sensitive to the ionization processes, at least up to a fluence of 7.1 × 1011 n cm−², as its radiation sensitivity coefficient (~3.36 dB km−1 Gy−1) under neutron exposure remains very similar to the one measured under X-rays (~3.8 dB km−1 Gy−1) at the same wavelength. The presented results open the way to the development of a point-like or even a distributed dosimeter for natural or man-made neutron-rich environments. The feasibility to measure the dose caused by the neutron exposure during stratospheric balloon experiments, or during outer space missions, is presented as a case study of a potential future application.

6 November 2018 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
Sylvain GirardSylvain Girard
Sylvain Girard
DDDiego Di.Francesca
Diego Di.Francesca
AMAdriana Morana
Adriana Morana
CHCornelia Hoehr
Cornelia Hoehr
PPP. Paillet
P. Paillet
MBM. Brugger
M. Brugger
We investigated the potential of a multimode (50-μm core diameter) nitrogen doped silica-based optical fiber for X-rays, protons, and y-rays radiation detection and dosimetry. X-rays results confirm that this N-doped fiber presents a strong radioluminescence (RL) around 550 nm when exposed to radiation. The RL observed from a few centimeter long samples linearly depend on the dose rate at least in the 1-mGy/s-50-Gy/s range. Low dose rate y-ray t ests demonstrate the radiation detection at dose rate as low as 40 μGy/s with a 2-m-long fiber sample. This fiber is also associated with an optically stimulated luminescence (OSL) when exposed to a 1064-nm laser light postirradiation. This OSL signature provides shortly after the irradiation a precise estimation of the accumulated dose at least in the 1-Gy-10-kGy range. Under proton exposure, we benchmarked the performances of the N-doped fiber with the ones of a conventional Markus chamber used by the TRIUMF proton-therapy team. This comparison highlights the potential of the small-size N-doped fiber to partially overcome the known limitations of commercial fiber-based dosimeters for medical applications. The obtained results are very promising for the future design of more complex spatially resolved beam monitoring systems.

16 May 2013 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
JMJ. Mekki
J. Mekki
MBM. Brugger
M. Brugger
SDS. Danzeca
S. Danzeca
LDL. Dusseau
L. Dusseau
KRK. Roed
K. Roed
GSG. Spiezia
G. Spiezia
RadFET sensors are used for Total Ionizing Dose (TID) monitoring inside CERN accelerators. While RadFET sensors are typically well characterized with a Co-60 gamma source, their radiation response can be affected when they are used in high-energy mixed particle fields. This paper presents experimental results and corresponding discussions on the effect of CERN accelerator-like environments on the dose measured by 100 nm, 400 nm and 1000 nm thick oxide RadFETs. Simulations of the radiation environment at the CERN test areas have also been performed to investigate the contribution of each particle type to the deposited dose and are used as a tool to understand the observed effects.

20 February 2024 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
MRMartin Roche
Martin Roche
NBNicolas Balcon
Nicolas Balcon
FCFlorence Clément
Florence Clément
PCPierrick Cheiney
Pierrick Cheiney
AMAdriana Morana
Adriana Morana
Sylvain GirardSylvain Girard
Sylvain Girard
LUMINA, a fiber-based dosimeter, exploiting the radiation induced attenuation phenomenon, is operational inside the International Space Station since August 2021. We discuss in this article its capability to detect possible signatures of recent solar particle events through the related increase of the dose rate radiation level within the International Space Station (ISS). Our analysis over 699 days of operation shows that the two LUMINA channels, operating either in the visible or infrared domains, are able to detect the slight dose rate increase related to the solar flares, in particular in the Poles regions. The South Atlantic Anomaly (SAA) remains well detected by both LUMINA channels, but no significant increase of the dose rates is noticeable during the solar events in this region. These results were obtained at dose rates close to the lower detection limit of our instrumentation, demonstrating the potential of fiber dosimeters, especially if less shielded, to detect the solar flares and monitor the radiation environment.