22 March 2023 in IEEE Transactions on Nuclear Science
RADNEXT is an EU-funded network of irradiation facilities and radiation effects experts aimed at increasing the quantity and quality of user access to accelerator infrastructure, and improving the diversity and harmonization across facilities. Along with the beam provision to worldwide radiation effects users, RADNEXT has an ambitious research program oriented at improving radiation effects testing, of which an example of a heavy ion facility inter-comparison at very different energy regimes is included in this work. In particular, energy deposition distributions in a silicon solid-state detector and the Single Event Upset (SEU) and Multiple Cell Upset (MCU) behaviour are compared amongst heavy ion beams of similar LET, but very different energies (i.e., from the more classical ~10 MeV/u regime up to several hundreds of MeV/u).
1 March 2013 in Journal of Propulsion and Power
Hybrid rocket combustion has important effects on rocket performance. The solid fuel regression rate is an important quantity in the hybrid rocket operation. In the past years, experimental and analytical investigations have been conducted to find correlations to correctly predict the regression rate. Numerical computations are becoming more important in the estimation of the characteristic parameters of such a complex combustion that embraces many different phenomena. This study predicts the regression rate of the Hydroxyl-Terminated Poly-Butadiene/Gaseous Oxygen formulation and its sensitivities to some operating parameters, such as combustion chamber pressure, oxygen inlet temperature, and mass flow rate. Furthermore, an analysis of other variables is used to explain the experimentally observed regression rate behavior. Particular emphasis is placed on the effect of the oxygen between the flame and the surface, which is considered responsible for the pyrolysis process enhancement.
22 February 2021 in IEEE Transactions on Nuclear Science
Proton direct ionization (PDI) from low-energy protons has been shown to have a potentially significant impact on the accuracy of prediction methods used to calculate the upset rates (URs) of memory devices in space applications for state-of-the-art deep submicron technologies. The general approach nowadays is to consider a safety margin to apply over the UR computed from high-energy proton and heavy-ion experimental data. The data reported here present a challenge to this approach. Different UR prediction methods are used and compared in order to establish the impact of PDI on the total UR. Regardless of the method employed, the findings suggest that PDI can contribute to up to 90% of the total UR, on average, for a general selection of space orbits, with peaks of up to 99%. Such results suggest that an approach based on the characterization of the low-energy portion of the proton spectrum would be more convenient for similar technologies than the application of a general safety margin. Based on data presented here, the previously proposed margin of 5 is exceeded, by large amounts in some cases.
9 March 2021 in IEEE Transactions on Nuclear Science
Neutrons with energies between 0.1 and 10 MeV can significantly impact the soft error rate (SER) in SRAMs manufactured in scaled technologies, with respect to high-energy neutrons. Their contribution is evaluated in accelerator, ground-level, and avionic (12 km of altitude) environments. Experimental cross sections were measured with monoenergetic neutrons from 144 keV to 17 MeV, and the results benchmarked with Monte Carlo simulations. It was found that even 144 keV neutrons can induce upsets due to elastic scattering. Moreover, neutrons in the 0.1-10 MeV energy range can induce more than 60% of the overall upset rate in accelerator applications, while their contribution can exceed 18% in avionics. The SER due to neutrons below 3 MeV, whose contribution has always been considered negligible, is found to be up to 44% of the total upsets in accelerator environments. These results have strong radiation hardness assurance (RHA) implications for those environments with high fluxes of neutrons in the 0.1-10 MeV energy range.
10 March 2021 in IEEE Transactions on Nuclear Science
Accelerated terrestrial neutron irradiations were performed on different commercial SiC power MOSFETs with planar, trench, and double-trench architectures. The results were used to calculate the failure cross sections and the failure-in-time (FIT) rates at sea level. Enhanced gate and drain leakage were observed in some devices which did not exhibit a destructive failure during the exposure. In particular, a different mechanism was observed for planar and trench gate MOSFETs, the first showing a partial gate rupture with a leakage path mostly between the drain and the gate, similar to what was previously observed with heavy ions, while the second exhibiting a complete gate rupture. The observed failure mechanisms and the postirradiation gate stress (PIGS) tests are discussed for different technologies.
9 April 2021 in IEEE Transactions on Nuclear Science
This article presents a static random access memory (SRAM)-based flexible radiation monitor. The monitor was fabricated in a 65-nm CMOS technology and it is designed as an application-specific integrated circuit, which comprises 768k bits SRAM cell matrix with individual power supply and a digital control core with a serial peripheral interface (SPI). By adjusting the core voltage of the SRAM matrix, the radiation sensitivity was made flexible. Also, SRAM cells with different threshold voltages were implemented to get further extension on tunable sensitivity range. The monitor has been tested under heavy ions with a linear energy transfer (LET) from 1.5 to 48.5 MeV·cm 2 /mg, high-energy (50-186 MeV) and low-energy (0.7-5 MeV) protons, and 14-MeV and thermal neutrons. An analysis was performed on how single-event upset sensitivity changes while tuning the supply voltage under different radiation environments. The results show that the monitor has the potential for space and facility applications.