Siming Guo

Siming Guo

Auto-generated profile, based on publicly available information

Siming Guo

National Institute of Metrology

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2021 in Nuclear Science and Techniques
Verified
Journal Article
Closed access
PDF file
SGSi-Ming Guo
Si-Ming Guo
JWJin-Jie Wu
Jin-Jie Wu
DHDong-Jie Hou
Dong-Jie Hou

13 January 2022 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
SGSiming Guo
Siming Guo
ZJZheng Jiang
Zheng Jiang
JWJinjie Wu
Jinjie Wu
XQXiaoyu Qie
Xiaoyu Qie
TYTao Yu
Tao Yu
JHJianwei Huang
Jianwei Huang

25 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
JCJian Chen
Jian Chen
JLJinjin Li
Jinjin Li
XXXiaolong XU
Xiaolong XU
ZWZhenyu Wang
Zhenyu Wang
SGSiming Guo
Siming Guo
XWXueshen Wang
Xueshen Wang
An absorber with a high absorbing efficiency is crucial for X-ray transition edge sensors (TESs) to realize high quantum efficiency and the best energy resolution. Semimetal Bismuth (Bi) has shown greater superiority than gold (Au) as the absorber due to the low specific heat capacity, which is two orders of magnitude smaller. The electroplating process of Bi films is investigated. The Bi grains show a polycrystalline rhombohedral structure, and the X-ray diffraction (XRD) patterns show a typical crystal orientation of (012). The average grain size becomes larger as the electroplating current density and the thickness increase, and the orientation of Bi grains changes as the temperature increases. The residual resistance ratio (RRR) (R300 K/R4.2 K) is 1.37 for the Bi film (862 nm) deposited with 9 mA/cm2 at 40 °C for 2 min. The absorptivity of the 5 μm thick Bi films is 40.3% and 30.7% for 10 keV and 15.6 keV X-ray radiation respectively, which shows that Bi films are a good candidate as the absorber of X-ray TESs.

17 October 2019 in The Journal of Engineering
Verified
Journal Article
Open access
PDF file
SGSiming Guo
Siming Guo
JWJinjie Wu
Jinjie Wu
JZJian Zhang
Jian Zhang
ZFZihao Fan
Zihao Fan
WCWeina Che
Weina Che
JWJi Wang
Ji Wang
The energy calibration and efficiency calibration of one silicon drift detector (SDD) are introduced here. The energy calibration is achieved using four radioactive sources, and the linear correlation coefficient is close to one. The efficiency curve of the SDD is obtained by Monte–Carlo simulations from 0.5 keV to 40 keV. Then, the efficiency of the SDD is calibrated using two radioactive sources. The results of experiments are compared with the calculated and the relative deviation are within 5.6%.

1 January 2024 in Nuclear Technology and Radiation Protection
Verified
Journal Article
Open access
PDF file
ZWZhen Wang
Zhen Wang
SGSiming Guo
Siming Guo
ZSZiyao Shu
Ziyao Shu
XZXing Zhou
Xing Zhou
ZLZhiwei Li
Zhiwei Li
JWJinjie Wu
Jinjie Wu
This study utilizes the monochromatic X-ray radiation device established by the National Institute of Metrology, China, to conduct a systematic experimental investigation of the mass attenuation coefficients of niobium, molybdenum, tantalum, and tungsten metals near their K absorption edges. The device's ability to generate continuously tunable monochromatic X-rays and accurately measure photon counts provides an ideal condition for precise mass attenuation coefficient measurements. This study employs a minimum energy step of 0.1 keV to systematically obtain the jump ratio rK and jump factor JK near the K-absorption edges of the four materials. The experimental measurements are compared with theoretical values from NIST-XCOM, NIST-FFAST, and Phy-x databases, demonstrating a consistent trend between the experimental and theoretical results, with relative deviations within acceptable limits, thereby validating the reliability of the theoretical models. An uncertainty analysis reveals a combined relative uncertainty of less than 2.7 %, indicating that the experimental results and theoretical values are in good agreement, with deviations and uncertainties within acceptable ranges. This research provides important experimental data and theoretical references for the application of monochromatic X-ray radiation devices in the field of mass attenuation coefficient measurements.

1 April 1999 in Applied Surface Science
Verified
Journal Article
Closed access
SCS.L Cheng
S.L Cheng
HHH.Y Huang
H.Y Huang
YPY.C Peng
Y.C Peng
LCL.J Chen
L.J Chen
BTB.Y Tsui
B.Y Tsui
JLJ.T Lin
J.T Lin