Francesco Guidi

Francesco Guidi

Auto-generated profile, based on publicly available information

Francesco Guidi

University of Florence

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
Daniele MazierliDaniele Mazierli
Daniele Mazierli
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
Enrico BoniEnrico Boni
Enrico Boni
FGFrancesco Guidi
Francesco Guidi
Piero TortoliPiero Tortoli
Piero Tortoli
Ultrasound open platforms are programmable and flexible tools for the development and test of novel methods. In most cases, they embed the electronics for the independent control of (maximum) 256 probe elements. However, a higher number of channels is needed for the control of 2-D array probes. This paper presents a system architecture that, through the hardware and software synchronization of multiple ULA-OP 256 scanners, may implement advanced open platforms with an arbitrary number of channels. The proposed solution needs a single personal computer, maintains real-time features, and preserves portability. A prototype demonstrator, composed of two ULA-OP 256 scanners connected to 512 elements of a matrix array, was implemented and tested according to different channel configurations. Experiments performed under MATLAB control confirmed that by doubling the number of elements (from 256 to 512) the signal-to-noise and contrast ratios improve by 9 dB and 3 dB, respectively. Furthermore, as a full 512-channel scanner, the demonstrator can produce real-time B-mode images at 18 Hz, high enough for probe positioning during acquisitions. Also, the demonstrator permitted the implementation of a new high frame rate, bi-plane, triplex modality. All probe elements are excited to simultaneously produce two planar, perpendicular diverging waves. Each scanner independently processes the echoes received by the 256 connected elements to beamform 1300 frames per second. For each insonified plane, good quality morphological (B-mode), qualitative (color flow-), and quantitative (spectral-) Doppler images are finally shown in real-time by a dedicated interface.

10 September 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
ADAlessandro Dallai
Alessandro Dallai
FGFrancesco Guidi
Francesco Guidi
LBLuca Bassi
Luca Bassi
Enrico BoniEnrico Boni
Enrico Boni
Piero TortoliPiero Tortoli
Piero Tortoli
Cardiovascular diseases, the leading cause of death in the world, are often associated with the dysfunction of the left ventricle. Even if, in clinical practice, the myocardial function is often assessed through visual wall motion scoring on B-mode images, quantitative techniques have been introduced, e.g. ultrasound tissue Doppler imaging (TDI). However, this technique suffers from the limited frame rate of currently available imaging techniques that needs to be balanced with the field of view. High frame rate (HFR) cardiac imaging has been recently tested off-line by simultaneously transmitting multiple focused beams into different directions and acquiring raw channel data into a PC. Several image lines were then reconstructed from the echoes of each transmission event. The same approach has been used to increase the TDI frame rate without restricting the field of view. This paper demonstrates the real-time feasibility of multiline transmission and acquisition methods for both HFR cardiac B-Mode and tissue Doppler imaging. These approaches have been implemented on the ULA-OP 256 research scanner, by taking care that the related resources were optimally exploited for these new applications. The obtainable performance in terms of image quality and frame rate has also been investigated. Experiments performed with a 128-element phased array probe show, for the first time, that real-time B-mode imaging is feasible at up to 1150 Hz without significant reduction in image quality or field-of-view. The implementation of a real-time TDI algorithm allowed obtaining TDI images with a frame rate of 288 Hz for a 90°-wide field-of view. Finally, in-vivo examples demonstrate the feasibility and the suitability of the method in clinical studies.

1 November 2013 in Leukemia & Lymphoma
Verified
Journal Article
Closed access
PDF file
Emiliano FabianiEmiliano Fabiani
Emiliano Fabiani
LFLuana Fianchi
Luana Fianchi
GFGiulia Falconi
Giulia Falconi
RBRiccardo Boncompagni
Riccardo Boncompagni
MCMarianna Criscuolo
Marianna Criscuolo
MVMaria Teresa Voso
Maria Teresa Voso
Therapy-related myeloid neoplasms (t-MNs) are an increasingly recognized complication in patients previously treated with radiotherapy and/or chemotherapy for cancer or autoimmune disease. Single nucleotide variants (SNVs) in genes involved in the cellular pathways of detoxification, DNA repair and apoptosis may modify the individual risk of developing a t-MN. We studied the frequency of the SNVs of six genes involved in xenobiotic detoxification (CYP3A4, NQO1, GSTA1, GSTM1, GSTP1 and GSTT1), two DNA repair genes (RAD51 and XRCC3) and one key regulator of apoptosis (BCL2L10) in a case–control study including 111 cases of t-MN and 259 controls. This is the first report on the prevalence of BCL2L10 Leu21Arg polymorphism in myeloid malignancies. In this line, we also tested 146 cases of de novo myelodysplastic syndrome (MDS) and 109 cases of de novo acute myeloid leukemia (AML). Our results showed a significantly lower frequency of the BCL2L10-21Arg allele in patients with t-MN and de novo MDS compared to controls (Leu/Arg + Arg/Arg: 50.6% vs. 65.9%, p = 0.017 and 45.8% vs. 65.9%, p = 0.0003, respectively). Carriers of the BCL2L10-21Arg variant have a reduced risk of developing t-MN and de novo MDS.

1 February 2000 in Bone Marrow Transplantation
Verified
Journal Article
Closed access
DFDaniela Frasca
Daniela Frasca
FGF Guidi
F Guidi
MAMariamena Arbitrio
Mariamena Arbitrio
CPClaudio Pioli
Claudio Pioli
FPF Poccia
F Poccia
GDG Doria
G Doria

10 March 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
FGFrancesco Guidi
Francesco Guidi
Piero TortoliPiero Tortoli
Piero Tortoli
Plane wave (PW) transmission (TX) can be profitably used to improve the performance of color flow mapping (CFM) systems by increasing the autocorrelation ensemble length (EL) and/or the frame rate (FR). Although high-end scanners tend to include imaging schemes using PW TX and parallel receive beams, high frame rate (HFR) CFM has been so far experimentally implemented mostly through research platforms that transmit PWs and beamform/process the received channel data off-line. In this article, full real-time implementation of PW CFM with continuous-time clutter filtering and extended FR/EL is reported. The field-programmable gate arrays (FPGAs) and digital signal processors (DSPs) onboard the ULA-OP 256 research scanner were programmed to perform high-speed parallel beamforming and autocorrelation-based CFM processing, respectively. Different strategies were tested, in which the TX of PWs for CFM is either continuous or interleaved with the TX of packets of B-mode pulses. A fourth-order Chebyshev continuous-time high-pass filter with programmable cutoff frequency was implemented and its clutter rejection performance was positively compared with that obtained when operating on packet data. CFM FRs up to 575 were obtained. The possibility of programming the autocorrelation EL up to 64 permitted to detect flow with high sensitivity and accuracy (average relative errors down to 0.4% ± 8.4%). In vivo HFR movies are presented, showing the dynamics of flow in the common carotid artery, which highlight the presence of secondary flow components.

23 August 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
FGFrancesco Guidi
Francesco Guidi
OSOuti Supponen
Outi Supponen
AUAwaneesh Upadhyay
Awaneesh Upadhyay
HVHendrik J. Vos
Hendrik J. Vos
MBMark Andrew Borden
Mark Andrew Borden
Piero TortoliPiero Tortoli
Piero Tortoli
Due to the primary radiation force, microbubble displacement has been observed previously in the focal region of single-element and array ultrasound probes. This effect has been harnessed to increase the contact between the microbubbles and targeted endothelium for drug delivery and ultrasound molecular imaging. In this study, microbubble displacements associated with plane-wave (PW) transmission are thoroughly investigated and compared to those obtained in focused-wave (FW) transmission over a range of pulse repetition frequencies, burst lengths (BLs), peak negative pressures, and transmission frequencies. In PW mode, the displacements, depending upon the experimental conditions, are in some cases consistently higher (e.g., by 28%, when the longest BL was used at PRF = 4 kHz), and the axial displacements are spatially more uniform compared to FW mode. Statistical analysis on the measured displacements reveals a slightly different frequency dependence of statistical quantities compared to transient peak microbubble displacements, which may suggest the need to consider the size range within the tested microbubble population.