Daniele Mazierli

Dr. Daniele Mazierli

Dipartimento di Ingegneria dell'Informazione, Università degli Studi di Firenze, Florence, Tuscany, Italy
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2021 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
Daniele MazierliDaniele Mazierli
Daniele Mazierli
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
Enrico BoniEnrico Boni
Enrico Boni
FGFrancesco Guidi
Francesco Guidi
Piero TortoliPiero Tortoli
Piero Tortoli
Ultrasound open platforms are programmable and flexible tools for the development and test of novel methods. In most cases, they embed the electronics for the independent control of (maximum) 256 probe elements. However, a higher number of channels is needed for the control of 2-D array probes. This paper presents a system architecture that, through the hardware and software synchronization of multiple ULA-OP 256 scanners, may implement advanced open platforms with an arbitrary number of channels. The proposed solution needs a single personal computer, maintains real-time features, and preserves portability. A prototype demonstrator, composed of two ULA-OP 256 scanners connected to 512 elements of a matrix array, was implemented and tested according to different channel configurations. Experiments performed under MATLAB control confirmed that by doubling the number of elements (from 256 to 512) the signal-to-noise and contrast ratios improve by 9 dB and 3 dB, respectively. Furthermore, as a full 512-channel scanner, the demonstrator can produce real-time B-mode images at 18 Hz, high enough for probe positioning during acquisitions. Also, the demonstrator permitted the implementation of a new high frame rate, bi-plane, triplex modality. All probe elements are excited to simultaneously produce two planar, perpendicular diverging waves. Each scanner independently processes the echoes received by the 256 connected elements to beamform 1300 frames per second. For each insonified plane, good quality morphological (B-mode), qualitative (color flow-), and quantitative (spectral-) Doppler images are finally shown in real-time by a dedicated interface.

1 February 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
LPLaura Peralta
Laura Peralta
Daniele MazierliDaniele Mazierli
Daniele Mazierli
AGAlberto Gomez
Alberto Gomez
JHJoseph V Hajnal
Joseph V Hajnal
Piero TortoliPiero Tortoli
Piero Tortoli
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
Coherent multitransducer ultrasound (CoMTUS) creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. The subwavelength localization accuracy of the multiple transducers required to coherently beamform the data is achieved by using the echoes backscattered from targeted points. In this study, CoMTUS is implemented and demonstrated for the first time in 3-D imaging using a pair of 256-element 2-D sparse spiral arrays, which keep the channel count low and limit the amount of data to be processed. The imaging performance of the method was investigated using both simulations and phantom tests. The feasibility of free-hand operation is also experimentally demonstrated. Results show that, in comparison with a single dense array system using the same total number of active elements, the proposed CoMTUS system improves spatial resolution (up to ten times) in the direction where both arrays are aligned, contrast-to-noise ratio (CNR; up to 46%), and generalized CNR (gCNR; up to 15%). Overall, CoMTUS shows a narrower main lobe and higher CNR, which results in an increased dynamic range and better target detectability.

28 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Claudio GiangrossiClaudio Giangrossi
Claudio Giangrossi
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
ADAlessandro Dallai
Alessandro Dallai
Daniele MazierliDaniele Mazierli
Daniele Mazierli
Valentino MeacciValentino Meacci
Valentino Meacci
Piero TortoliPiero Tortoli
Piero Tortoli
The spread of high frame rate and 3-D imaging techniques has raised pressing requirements for ultrasound systems. In particular, the processing power and data transfer rate requirements may be so demanding to hinder the real-time (RT) implementation of such techniques. This paper first analyzes the general requirements involved in RT ultrasound systems. Then, it identifies the main bottlenecks in the receiving section of a specific RT scanner, the ULA-OP 256, which is one of the most powerful available open scanners and may therefore be assumed as a reference. This case study has evidenced that the “star” topology, used to digitally interconnect the system’s boards, may easily saturate the data transfer bandwidth, thus impacting the achievable frame/volume rates in RT. The architecture of the digital scanner was exploited to tackle the bottlenecks by enabling a new “ring“ communication topology. Experimental 2-D and 3-D high-frame-rate imaging tests were conducted to evaluate the frame rates achievable with both interconnection modalities. It is shown that the ring topology enables up to 4400 frames/s and 510 volumes/s, with mean increments of +230% (up to +620%) compared to the star topology.

2 October 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
LPLaura Peralta
Laura Peralta
Daniele MazierliDaniele Mazierli
Daniele Mazierli
KCKirsten Christensen-Jeffries
Kirsten Christensen-Jeffries
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
Piero TortoliPiero Tortoli
Piero Tortoli
JHJoseph V. Hajnal
Joseph V. Hajnal
Coherent multi-transducer ultrasound (CoMTUS) imaging creates an extended effective aperture through the coherent combination of multiple arrays, which results in images with enhanced resolution, extended field-of-view, and higher sensitivity. However, this also creates a large discontinuous effective aperture that presents additional challenges for current beamforming methods. The discontinuities may increase the level of grating and side lobes and degrade contrast. Also, direct transmissions between multiple arrays, happening at certain transducer relative positions, produce undesirable cross-talk artifacts. Hence, the position of the transducers and the scan sequence play key roles in the beamforming algorithm and imaging performance of CoMTUS. This work investigates the role of the distribution of the individual arrays and the scan sequence in the imaging performance of a coherent dual-array system. First, the imaging performance for different configurations was assessed numerically using the point-spread-function, and then optimized settings were tested on a tissue mimicking phantom. Finally, a subset of the proposed optimum imaging schemes was experimentally validated on two synchronized ULA OP-256 systems equipped with identical linear arrays. Results show that CoMTUS imaging performance can be enhanced by optimizing the relative position of the arrays and the scan sequence together, and that the use of apodization can reduce cross-talk artifacts without degrading spatial resolution. Adding weighted compounding further decreases artifacts and helps to compensate for the differences in the brightness across the image. Setting the maximum steering angle according to the spatial configuration of the arrays reduces the sidelobe energy up to 10 dB plus an extra 4 dB reduction is possible when increasing the number of PWs compounded.

4 July 2025 in Ultrasonics
Verified
Journal Article
Open access
PDPaul Dryburgh
Paul Dryburgh
Daniele MazierliDaniele Mazierli
Daniele Mazierli
JHJoseph V. Hajnal
Joseph V. Hajnal
Piero TortoliPiero Tortoli
Piero Tortoli
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
LPLaura Peralta
Laura Peralta
Coherent multi-transducer ultrasound (CoMTUS) imaging enables the use of multiple arrays as one large effective aperture yielding images with enlarged field-of-view, improved resolution, and higher signal-to-noise ratio. However, creating a large but discontinuous effective aperture increases the grating and sidelobe levels, and generates cross-talk artifacts between arrays. These additional challenges can degrade the contrast of the images obtained through the classic Delay and Sum (DAS) beamforming algorithm. This study investigates the possibility to improve contrast and reduce artifacts in CoMTUS by using an alternative nonlinear beamforming algorithm, the Filtered Delay Multiply and Sum (F-DMAS). We implemented a specific F-DMAS beamforming algorithm for CoMTUS considering the resulting effective aperture and tested its performance in a coherent dual-array system for 2-D imaging. The comparison between CoMTUS images obtained through F-DMAS and DAS was investigated by both simulations and experiments, including in vivo results. For a typical dual-probe configuration, CoMTUS specific F-DMAS was shown to be effective at lowering the sidelobes and the noise floor, resulting in better quality B-mode images with improved sidelobe suppression (first sidelobe amplitude decreased from -13.0 dB to -24.7 dB; side-lobe-to-main-lobe energy ratio decreased from 9.3 dB to 1.9 dB).

1 January 2026 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Open access
Daniele MazierliDaniele Mazierli
Daniele Mazierli
Piero TortoliPiero Tortoli
Piero Tortoli
LPLaura Peralta
Laura Peralta
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
Objective: The current vector velocity measurement techniques are typically limited by probe apertures, which restrict their use to superficial vessels. This work introduces a high frame rate method based on the use of multiple array probes transmitting defocused beams and shows that such a method permits accurate and precise measurements of blood velocities in deep and large regions/volumes of interest. Methods: Multiple probes are positioned to investigate a common region of interest and activated in a sequence. The corresponding phase shifts are estimated and combined through a least square error approach to derive the velocity vector. The method's performance has been quantitatively evaluated in both 2-D and 3-D scenarios through simulations based on either two linear- or three matrix sparse-array probes. Results: Good estimations of both module (average rmse(v) 11.9% of vmax) and direction (average rmse(α) 2.3° and rmse(β) 8.0°) of the velocity vectors have been obtained. The corresponding vector velocity frames cover wide areas or volumes even around depths as high as 80 mm. Conclusions: This simulation work demonstrates that multi-probe configurations can be exploited to measure the 2-D or 3-D flow velocity accurately and precisely in deep and large regions of interest. Significance: In a clinical scenario, for example, the method could be exploited for velocity estimation in the abdominal region where large and deep vessels, such as the aorta, are located.