Andrew K. LaPre

Andrew K. LaPre

Auto-generated profile, based on publicly available information

Andrew K. LaPre

FTL Labs Corp. Amherst Massachusetts USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2017 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
ALA.K. LaPrè
A.K. LaPrè
MPM.A. Price
M.A. Price
RWRyan D. Wedge
Ryan D. Wedge
BUB.R. Umberger
B.R. Umberger
FSFrank C. Sup
Frank C. Sup

13 November 2019 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
MPMark A. Price
Mark A. Price
ALAndrew K. LaPrè
Andrew K. LaPrè
RJRussell T. Johnson
Russell T. Johnson
BUBrian R. Umberger
Brian R. Umberger
FSFrank C. Sup
Frank C. Sup
Marker‐based motion capture techniques are commonly used to measure human body kinematics. These techniques require an accurate mapping from physical marker position to model marker position. Traditional methods utilize a manual process to achieve marker positions that result in accurate tracking. In this work, we present an optimization algorithm for model marker placement to minimize marker tracking error during inverse kinematics analysis of dynamic human motion. The algorithm sequentially adjusts model marker locations in 3‐D relative to the underlying rigid segment. Inverse kinematics is performed for a dynamic motion capture trial to calculate the tracking error each time a marker position is changed. The increase or decrease of the tracking error determines the search direction and number of increments for each marker coordinate. A final marker placement for the model is reached when the total search interval size for every coordinate falls below a user‐defined threshold. Individual marker coordinates can be locked in place to prevent the algorithm from overcorrecting for data artifacts such as soft tissue artifact. This approach was used to refine model marker placements for eight able‐bodied subjects performing walking trials at three stride frequencies. Across all subjects and stride frequencies, root mean square (RMS) tracking error decreased by 38.4% and RMS tracking error variance decreased by 53.7% on average. The resulting joint kinematics were in agreement with expected values from the literature. This approach results in realistic kinematics with marker tracking errors well below accepted thresholds while removing variance in the model‐building procedure introduced by individual human tendencies.

14 March 2020 in International Journal for Numerical Methods in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
VNVinh Q. Nguyen
Vinh Q. Nguyen
ALAndrew K. LaPre
Andrew K. LaPre
MPMark A. Price
Mark A. Price
BUBrian R. Umberger
Brian R. Umberger
FSFrank C. Sup
Frank C. Sup

1 July 2017
Verified
Conference Paper
Closed access
ALAndrew K. LaPre
Andrew K. LaPre
VNVinh Q. Nguyen
Vinh Q. Nguyen
UBUlvi Baspinar
Ulvi Baspinar
MWMichael White
Michael White
FSFrank C. Sup
Frank C. Sup
The acceptance of advanced prosthetic systems by users requires overcoming unique challenges of fitting prostheses to unique user anatomies to achieve systematic performance across a user base. Variations among individuals introduce complexities in fitting the sockets. Due to the difficulty of measuring socket interface characteristics, there is a lack of quantifiable diagnostic fitment information available. As a result, the process of fitting sockets is currently a laborintensive, manual approach, and can often result in sockets that are uncomfortable, unstable, or impede full range of motion. Additionally, results can be difficult to reproduce reliably. A diagnostic tool has been developed to quantify the relative movement between the socket and the residual bone during the fitting process. The approach leverages low cost and high precision ultrasound transceivers and intuitive visualization software to provide quantifiable socket fitment data. The goal is to enable a systematic socket-fitting strategy that yields reliable and reproducible results. Human subject testing and results are presented that show movement tracking relative to a cuff with an ultrasound transducer with an RMSD of 0.36 mm.