Immacolata Angelica Grimaldi

Immacolata Angelica Grimaldi

Auto-generated profile, based on publicly available information

Immacolata Angelica Grimaldi

Institute for Electromagnetic Monitoring of the Environment (IREA), National Research Council (CNR), Naples, Italy

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2017 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
GPGianluca Persichetti
Gianluca Persichetti
IGI. A. Grimaldi
I. A. Grimaldi
GTGenni Testa
Genni Testa
RBRomeo Bernini
Romeo Bernini
A multifunctional lab-on-a-chip platform for spectroscopic analysis of liquid samples based on an optofluidic jet waveguide is reported. The optofluidic detection scheme is achieved through the total internal reflection arising in a liquid jet of only 150 μm diameter, leading to highly efficient signal excitation and collection. This results in an optofluidic chip with an alignment-free spectroscopic detection scheme, which avoids any background from the sample container. This platform has been designed for multiwavelength fluorescence and Raman spectroscopy. The chip integrates a recirculation system that reduces the required sample volume. The evaluation of the device performance has been accomplished by means of fluorescence measurements performed on eosin Y in water solutions, achieving a limit of detection of 33 pM. The sensor has been applied in Raman spectroscopy of water–ethanol solutions, leading to a limit of detection of 0.18%. As additional application, analysis of riboflavin using fluorescence detection demonstrates the possibility of detecting this vitamin at the 560 pM level (0.21 ng l−1). Although measurements have been performed by means of a compact and low-cost spectrometer, in both cases the micro-jet optofluidic chip achieved similar performances if not better than high-end benchtop based laboratory equipment. This approach paves the way towards portable lab-on-a-chip devices for high sensitivity environmental and biochemical sensing, using optical spectroscopy.

8 December 2014 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
IGI. A. Grimaldi
I. A. Grimaldi
Simone BerneschiSimone Berneschi
Simone Berneschi
GTGenni Testa
Genni Testa
Francesco BaldiniFrancesco Baldini
Francesco Baldini
GCGualtiero Nunzi Conti
Gualtiero Nunzi Conti
RBRomeo Bernini
Romeo Bernini
The investigation of a simple and self-assembling method for realizing polymeric micro-bottle resonators is reported. By dispensing precise amounts of SU-8 onto a cleaved optical fiber, employed as mechanical support, bottle microcavities with different shapes and diameters are fabricated. The balancing of surface energy between glass fiber and polymeric microresonator with surface tension of SU-8 confers different shape to these microstructures. Planar single-mode SU-8 based waveguide, realized on polymethylmethacrylate, is chosen for exciting the micro-bottle resonators by evanescent wave. The reliability of the fabrication process and the shape of the bottle microcavities are investigated through optical analysis. We observe whispering gallery modes in these resonant microstructures by a robust coupling with single mode planar waveguides around 1.5 μm wavelength. The resonance spectra of micro-bottle resonators and the spectral characteristics, such as Quality-factor (Q factor) and free spectral range, are evaluated for all the realized microstructures. SU-8 micro-bottle resonators show high Q-factors up to 3.8 × 104 and present a good mechanical stability. These features make these microcavities attractive for sensing and/or lasing applications in a planar platform.

1 December 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
IGImmacolata Angelica Grimaldi
Immacolata Angelica Grimaldi
GTGenni Testa
Genni Testa
GPGianluca Persichetti
Gianluca Persichetti
FLFausta Loffredo
Fausta Loffredo
FFFulvia FULVIA
Fulvia FULVIA
RBRomeo Bernini
Romeo Bernini

19 June 2012 in Optics Letters
Verified
Journal Article
Closed access
PDF file
IGI. A. Grimaldi
I. A. Grimaldi
SCS. Coppola
S. Coppola
FLF. Loffredo
F. Loffredo
FFFulvia FULVIA
Fulvia FULVIA
CMC. Minarini
C. Minarini
PFPietro Ferraro
Pietro Ferraro
The investigation of a method for fabricating microlenses by a nozzle-free inkjet printing approach is reported. The new method, based on a pyroelectrohydrodynamic mechanism, is also able to dispense viscous liquids and to draw liquid phase drops directly from the reservoir. Specifically, by dispensing optical grade polymer dissolved in different solvent mixtures, microlenses were printed with a pattern defined directly through this deposition method. The reliability of the microlenses and the tunability of their focal properties were demonstrated through profilometric and inteferometric analyses.

4 November 2013 in Applied Optics
Verified
Journal Article
Closed access
PDF file
IGI. A. Grimaldi
I. A. Grimaldi
SCS. Coppola
S. Coppola
FLF. Loffredo
F. Loffredo
FFFulvia FULVIA
Fulvia FULVIA
GNG. Nenna
G. Nenna
PFPietro Ferraro
Pietro Ferraro
In the present work, the pyro-electrohydrodynamic technique was used for the realization of tunable-size microlens arrays. Poly(methyl methacrylate) dissolved in different solvent mixtures was used as the polymeric material for the realization of the microstructures. By controlling the experimental parameters and in particular, the volume of the drop reservoir, graded-size square arrays of tens of microlenses with focal length in the range 1.5–3 mm were produced. Moreover, the optical quality and geometrical features were investigated by profilometric and interferometric analysis.

11 August 2011 in Journal of Applied Polymer Science
Verified
Journal Article
Closed access
PDF file
IGI. A. Grimaldi
I. A. Grimaldi
AMA. De Girolamo Del Mauro
A. De Girolamo Del Mauro
GNG. Nenna
G. Nenna
FLF. Loffredo
F. Loffredo
CMC. Minarini
C. Minarini
FFFulvia FULVIA
Fulvia FULVIA