11 April 2019 in IEEE Transactions on Power Delivery
The fast dc line protection is one of the key techniques for the multi-terminal flexible dc grid whose main technical difficulty lies in quick and reliable fault identification. The traditional protection principles for the ac system are not suitable for the flexible dc grid, and those for the conventional dc transmission system can also not be applied directly. Therefore, the frequency-domain traveling-wave boundary characteristics after faults are analyzed first in this paper to find the critical condition for distinguishing the internal and external faults as well as the forward and backward faults. And then, a novel single-ended transient-voltage-based protection strategy for flexible dc grid was proposed, which mainly consists of the fault identification criterion and the direction criterion. The protection scheme used wavelet transform to extract transient voltage energy. In order to eliminate the influences of the wavelet transform boundary effect and converter blocking, the principle to select the proper data window was proposed. Compared with the existing traveling-wave-based dc protection, the proposed method has a higher reliability and stronger ability to endure high transition resistance, which was verified by lots of simulation cases based on the PSCAD/EMTDC.
25 June 2018 in IEEE Transactions on Power Electronics
DC fault current limitation is important for the low voltage dc distribution network, because the existing dc selective protection cannot act fast enough. However, the typical dc fault current limiting method—installing dc reactors directly in the dc system—will lead to negative influences on the system normal operation and dc circuit breaker (DCCB) fast isolation. This paper proposed a novel solid-state circuit breaker (SSCB) with self-adapt fault current limiting capability, namely, no negative influence on the dc distribution network normal operation, swift fault current limiting response to the dc fault, and efficient cooperation between the fault current limitation and isolation. The hybrid configuration strategy of the proposed SSCB and mechanical DCCB for multi-terminal dc distribution network is proposed to reduce the conducting power loss and investment from the scale of the whole system. Finally, the experiment tests and simulation cases are carried out to verify the working principle and superiorities of the proposed SSCB.
30 August 2019 in IEEE Transactions on Power Delivery
The overhead line will be widely applied in the future flexible high voltage dc (HVDC) grid. Correspondingly, effective reclosing strategy which can identify the fault property must be configured for the dc circuit breaker (DCCB) to improve the system power supply reliability. However, if the DCCB is reclosed directly, large second overcurrent may occur to damage the vulnerable devices in the system. Therefore, the inherent voltage characteristic difference between different dc faults (nonpermanent or permanent) is analyzed in the paper. And then a novel DCCB reclosing strategy for the flexible HVDC grid is proposed. Compared with the method which recloses DCCB directly, the proposed strategy can avoid the second damage under permanent fault condition, because it can identify the fault property without completely reclosing the DCCB (only the residual dc current breaker is reclosed before fault property identification). Moreover, compared with the typical sequential auto-reclosing strategy, the proposed strategy significantly reduces the additional control and design requirements on the DCCB. Finally, simulation cases based on the PSCAD/EMTDC are carried out to verify the correctness of the theoretical analysis and the superiorities of the proposed reclosing strategy.
16 November 2018 in IEEE Transactions on Power Electronics
Medium voltage direct current (MVDC) distribution system has numerous advantages over medium voltage alternative current (MVAC) distribution system. However, two shortcomings of the existing hybrid direct current circuit breaker (DCCB) with load current switch (LCS), including high construction cost and high operating losses, have constrained the application of existing hybrid DCCBs in MVDC distribution system. To overcome these two shortcomings, a novel multi-port hybrid DCCB with negative voltage source (NVS) has been proposed in this paper. First, the general topology and working principle of the multi-port hybrid DCCB with NVS are presented. Then, focused on current commutation method and economic performance, comparisons between different hybrid DCCBs have been carried out. The analysis shows that by using multi-port hybrid DCCB with NVS, the construction cost could be reduced dramatically and the operating losses could be reduced to be comparable with alternative current circuit breaker (ACCB) which are negligible. In the end, to fill the blank of experimental research, based on the topology of multi-port hybrid DCCB with NVS, a prototype with rating voltage of 2kV has been established, and the test result have verified the multi-port hybrid DCCB with NVS.
3 February 2020 in IEEE Transactions on Power Delivery
Fast and reliable direction criterion is important for the protection of multi-terminal HVDC grid, not only for direction pilot protection, but also for excluding backward fault in singleended protection. The direction criteria based on dc current variation (Δi) or dc current change rate (di/dt) have been used in the dc transmission system. However, the acting reliability is influenced by the high-transition resistance, line distributed capacitance, and so on. Although the direction criteria based on the boundary effect of the dc reactor have excellent operation performance in dc grid, they are only feasibility when the dc reactors are installed on both ends of each dc line. In this paper, the traveling-wave (TW) based direction criterion, which is not based on the boundary components, is proposed for use in multi-terminal HVDC grid, and its applicability is analyzed. To improve the acting sensitivity and reliability of the TW based direction criterion, an improved transient TW based direction criterion is proposed. Finally, simulations based on the Real Time Digital Simulator (RTDS) are carried out to verify the feasibility and superiority of the proposed improved direction criterion.
20 June 2019 in IEEE Transactions on Power Electronics
In the flexible dc grid, the dc fault propagates extremely fast. It requires the dc protection and dc circuit breaker (DCCB) can identify and isolate the fault line very quickly, for the healthy network ride-through, especially in the multi-terminal dc grids. However, the existing protection and DCCB techniques for flexible dc grid can still not match the dc fault propagation speed. Therefore, a novel current-commutation-based fault current limiter (FCL) is proposed in this paper. It can limit the dc fault current effectively, to guarantee the converter continuous operation and healthy network ride-through after dc faults, so the requirement on the protection and DCCB acting speed can be decreased. Compared with the existing fault current limiting methods, the proposed FCL has tiny negative influence on the system transient response speed, operation stability, and DCCB isolating speed. The experiment tests and simulation case studies are carried out to verify the working principle and superiorities of the proposed novel FCL.