16 February 2026 in Measurement
10 November 2025 in IEEE Sensors Journal
Conductivity sensing plays a crucial role in biochemical and industrial process monitoring, particularly in complex liquid environments such as fermentation systems. This study developed a monolithically integrated sensor based on microelectromechanical systems (MEMS) technology, which innovatively combines a concentric four-electrode conductivity sensor with a four-wire platinum resistance temperature detector (RTD). The sensor is designed to track fermentation progress by performing in situ, real-time monitoring of conductivity and temperature variations. Electric field simulations based on rigorous geometric modeling confirmed the establishment of a uniform sensing field between the current excitation electrodes, effectively confining the measurement region. This concentric ring electrode design successfully generated a uniform current density field between the two voltagesensing electrodes, thereby providing an ideal condition for accurate solution conductivity measurement. The sensor was fabricated on a BF33 glass substrate using standard MEMS processes, including photolithography, ion beam etching (IBE), and plasma-enhanced chemical vapor deposition (PECVD) of a SiO2 insulation layer, achieving high integration and batch manufacturability. Comprehensive performance characterization verified its excellent microstructural characteristics and electrochemical performance. The sensor demonstrated outstanding overall performance: a temperature measurement accuracy of ±0.3%, a conductivity measurement accuracy of ±2%; excellent long-term stability with a monthly drift of less than 0.2% for the temperature sensor and less than 3% for the conductivity sensor. A compensation model, established using the integrated temperature sensor, effectively eliminated the impact of temperature fluctuations on conductivity measurements. Ultimately, in a practical yogurt fermentation application, the conductivitytime profile obtained by this sensor showed close agreement with the trend measured by a pH sensor, successfully revealing the dynamic changes of key fermentation stages. This study not only validates the high reliability of the integrated sensor but also provides a solid foundation for its broad application in monitoring complex biological processes.
31 March 2026 in IEEE Sensors Journal
Precise in-situ measurement of marine environmental parameters is fundamental to oceanographic research and resource development. While Micro-Electro-Mechanical Systems (MEMS) technology offers a novel pathway for sensor miniaturization, existing electrode designs remain limited. Traditional two-electrode structures suffer from severe signal drift due to electrode polarization effects, while improved four-electrode configurations struggle to completely eliminate polarization interference at the micro-scale, thereby hindering further enhancements in measurement accuracy. To address these challenges, this study presents a monolithically integrated MEMS conductivity-temperature (CT) sensor designed for ocean observation. The core innovation involves a novel seven-electrode differential structure that utilizes square-wave excitation to effectively suppress polarization effects and common-mode noise. Additionally, the monolithic integration of a thin-film platinum resistance temperature detector (RTD) and the conductivity sensor is achieved via MEMS processes, effectively eliminating spatiotemporal synchronization errors. Furthermore, a Back Propagation (BP) neural network algorithm is introduced to address the temperature dependence of conductivity measurements, significantly resolving the issue of temperature-salinity cross-sensitivity. The sensing structure was optimized via COMSOL simulations to mitigate complex multi-electrode electric field coupling. Experimental results demonstrate measurement accuracies better than ±0.004 °C for temperature and ±0.01 mS/cm for conductivity. Following BP neural network compensation, the conductivity measurement error across a wide temperature range is significantly reduced to ±0.02 mS/cm. In field trials conducted in actual sea areas, the sensor successfully captured thermocline and halocline profiles. The obtained data showed high consistency with commercial high-precision equipment, verifying the reliability and superiority of the proposed scheme.
4 February 2026 in IEEE Sensors Journal
This study designed and fabricated a MEMS Pt thin-film temperature sensor suitable for the medium-to-high temperature range of 33-600 °C. A Pt film with a thickness of approximately 1 μm was deposited on an Al₂O₃ ceramic substrate via magnetron sputtering, and annealing experiments were conducted within the temperature range of 500-1000 °C. The microstructure, morphology, and crystal orientation of the thin film were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD), while the resistance-temperature curve, resistance change rate, and temperature coefficient of resistance (TCR) of the sensor were tested. The results show that annealing at 800 °C for 4 hours is the optimal process: under this condition, the platinum thin film exhibits a strong (111) crystal orientation preference with uniform and dense grains. The TCR increases from 2740 ppm/°C before annealing to 3742 ppm/°C, and the resistance change rate reaches -26.14%. Within the range of 33-600 °C, the maximum temperature measurement error is less than 0.2%, the temperature drift is less than 0.08% FS, and the resistance-temperature curve shows excellent linearity. This sensor, featuring both high precision and stability, is suitable for high-precision temperature measurement scenarios in medium-to-high temperature environments, such as hot-end monitoring of aerospace engines and diagnosis of automotive exhaust systems.