Francesco Verducci

Francesco Verducci

Auto-generated profile, based on publicly available information

Francesco Verducci

Politecnico di Milano

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2024 in Renewable Energy
Verified
Journal Article
Open access
FVFrancesco Verducci
Francesco Verducci
AGAmedeo Grimaldi
Amedeo Grimaldi
ECElena Colombo
Elena Colombo
ACAndrea Casalegno
Andrea Casalegno
ABAndrea Baricci
Andrea Baricci

19 September 2024 in International Journal of Hydrogen Energy
Verified
Journal Article
Open access
DCDelio Casadei
Delio Casadei
FVFrancesco Verducci
Francesco Verducci
AGAmedeo Grimaldi
Amedeo Grimaldi
DCDiego Croci
Diego Croci
APAlessandro Palmieri
Alessandro Palmieri
ABAndrea Baricci
Andrea Baricci

15 October 2025 in Journal of Power Sources
Verified
Journal Article
Open access
FVFrancesco Verducci
Francesco Verducci
LCLivio Cultrera
Livio Cultrera
ECElena Colombo
Elena Colombo
AFAixeen Manuel Fontanilla
Aixeen Manuel Fontanilla
FCFrancesco Casamichiela
Francesco Casamichiela
ABAndrea Baricci
Andrea Baricci

24 November 2025 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
FVFrancesco Verducci
Francesco Verducci
AGAmedeo Grimaldi
Amedeo Grimaldi
ECElena Colombo
Elena Colombo
LCLivio Cultrera
Livio Cultrera
DCDelio Casadei
Delio Casadei
ABAndrea Baricci
Andrea Baricci
The durability of Polymer Electrolyte Membrane Fuel Cells (PEMFC) is a crucial factor for enhancing their competitiveness in the heavy-duty sector. In this sense, the cathode catalyst layer (CCL) and the polymer electrolyte membrane (PEM) represent the two most critical components of the stack. To mitigate the chemical degradation of the membrane, radical scavenger, such as cerium (Ce) ions, are typically adopted in PEMFC [1]. However, as shown recently in the literature [2,3], during real operation they migrate in the in-plane direction driven by concentration and potential gradients losing their scavenging efficacy and introducing additional performance loss. Therefore, it is essential to fully understand the major degradation mechanisms and assess their impact on the performance and lifetime of the technology. Accelerated stress tests (ASTs) are generally adopted with the aim of accelerating the characterization of durable materials by mimicking the main ageing mechanisms occurring during real-world operation. However, no protocols are already consolidated for heavy-duty applications. In this scenario, based on vehicle data from the IMMORTAL project [4], ad-hoc simulations were carried out by a 1+1D PEMFC stack model [5] to identify voltage transitions and holding times at both low and high power. The modelling analysis resulted in the heavy-duty AST protocol shown in Figure 1(a), which is characterized by an acceleration factor equal to 6. The ageing heterogeneity over the fuel cell area was studied by means of a segmented cell hardware whose active area was divided in 5 different portions and which adopts a counterflow configuration. Furthermore, an innovative model framework, coupling a 1+1D PEMFC performance model [5] with a semi-empirical electrocatalyst active surface area (ECSA) loss model and a 1D in-plane cerium transport model, was developed to better understand the drivers responsible for the experimentally observed performance ageing and to propose ad-hoc mitigation strategies. After 1100 cycles, i.e. 5000 operating hours, the 18% of the initial ECSA is lost (Figure 1(b)). Moreover, as revealed by both model simulations and a x-ray fluorescence (XRF) analysis (Figure 1(c)), after 1100 cycles of the heavy-duty AST protocol, a significant in-plane Ce redistribution was observed, with an accumulation at air inlet and outlet regions and a depletion in the middle regions of the cell. Since Ce mobility negatively affects both PEMFC lifetime and performance, decreasing protonic conductivity [1] and oxygen diffusion in CCL [2], it is crucial to stabilize it within the membrane for as long as possible. For this purpose, the above-mentioned model framework was used, first, to identify the material properties that mostly affect Ce transport and, later, to design an innovative material-based solution able to significantly limit the mobility of radical scavenger in the in-plane direction. Figure 1

24 November 2025 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
AGAmedeo Grimaldi
Amedeo Grimaldi
FVFrancesco Verducci
Francesco Verducci
FZFilippo Zampedri
Filippo Zampedri
DCDelio Casadei
Delio Casadei
ECElena Colombo
Elena Colombo
ABAndrea Baricci
Andrea Baricci
In recent years, Proton Exchange Membrane Fuel Cells (PEMFCs) have gained increasing attention as a commercial option for light-duty vehicles and a promising solution for heavy-duty applications, where system design remains an active area of research 1 . Ensuring the efficient and durable operation of PEMFCs requires a comprehensive understanding of the local operating conditions within the membrane-electrode assembly (MEA). Effective numerical modelling is crucial for unravelling the complexities of local heterogeneities arising from interactions among different system components. However, there is a need for models that are both computationally efficient and physically consistent. This study develops a detailed physical model of a fuel cell system based on a typical system architecture, with a primary focus on the PEMFC stack. The model employs a 1+1D multiphase, dynamic, non-isothermal approach based on previous works 2 . It accounts for mass dynamics in channels and gas diffusion layers, as well as membrane hydration and dehydration mechanisms, incorporating the impact of two platinum oxides species on oxygen reduction reaction (ORR) kinetics 3 . Additionally, air and hydrogen feed subsystems are modelled alongside the thermal management system, which plays a critical role in heavy-duty applications. The governing equations are implemented in the MATLAB Simulink environment using Simscape libraries, significantly reducing computational time, by at least a factor of 30, compared to an in-house model developed purely in Simulink 2 . This improvement enables faster-than-real-time simulation capability. The PEMFC system model, as visible in Figure 1(a), along with control strategies, is calibrated and validated using experimental data from an online database provided by the Argonne National Laboratory, based on a commercial light-duty vehicle 4 . Further validation is performed using experimental data obtained from a heavy-duty protocol, developed within the Italian project PERMANENT, on a five-segment single-cell PEMFC hardware, shown in Figure 1(b). A reference layout for the heavy-duty fuel cell system is selected based on publicly available data, and its dynamic performance is analysed under representative driving cycle conditions. A sensitivity analysis is conducted to evaluate the impact of component design and operational strategies, with a particular focus on the thermal management system (TMS) and its control, examining their influence on local operating conditions within the MEA and their subsequent impact on durability, exploiting a semi-empirical catalyst durability model 5 . The study investigates how TMS configurations affect fuel cell performance and durability, once defined the extent of hybridization level within the energy management system. References B. James et al., Heavy-Duty Fuel Cell System Cost – 2023 , p. 1–12, (2024) https://www.hydrogen.energy.gov/docs/hydrogenprogramlibraries/pdfs/review24/24004-hd-fuel-cell-system-cost-2023.pdf?sfvrsn=70ff384f_3. F. Verducci, A. Grimaldi, E. Colombo, A. Casalegno, and A. Baricci, Renew. Energy , 234, 121194 (2024) https://linkinghub.elsevier.com/retrieve/pii/S096014812401262X. T. Jahnke, A. Baricci, C. Rabissi, and A. Casalegno, J. Electrochem. Soc. , 167, 149001 (2020) https://iopscience.iop.org/article/10.1149/1945-7111/abbfda. H. Lohse-Busch et al., Technology Assessment Of A Fuel Cell Vehicle: 2017 Toyota Mirai , Argonne, IL (United States), (2018) http://www.osti.gov/servlets/purl/1463251/. A. Grimaldi, F. Verducci, E. Colombo, A. Casalegno, and A. Baricci, ECS Meet. Abstr. , MA2023-02, 1703–1703 (2023) https://dx.doi.org/10.1149/MA2023-02371703mtgabs. Figure 1

24 November 2025 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
DMDaniele Mora
Daniele Mora
ECElena Colombo
Elena Colombo
FVFrancesco Verducci
Francesco Verducci
ACAlessio Cancian
Alessio Cancian
MMMichele Merizzi
Michele Merizzi
ACAndrea Casalegno
Andrea Casalegno
PEM fuel cell are set to be a very important solution for the decarbonization of the heavy-duty transport sector, due to their main advantage of power and energy scalability at lower additional weight compared to lithium-ion battery alternatives. Materials durability is one of the main challenges for this technology, especially for the longer lifetimes expected by this kind of applications 1 . While significant efforts were devoted to study specific degradation mechanisms, there is a lack of works devoted to investigate PEM fuel cell ageing under conditions representative of real world application. The latter approach is crucial to design innovative materials and develop optimized mitigation strategies to increase components lifetime. In this work, carried out within the framework of the Italian project PERMANENT, an extensive experimental campaign was performed to assess degradation under heavy-duty conditions. Following the approach adopted in previous works from our research group 2 , an Accelerated Stress Test (AST) protocol was developed to mimic real heavy-duty operation starting from real vehicle data available in literature 3 . The impact of operating temperature was investigated, as the AST was carried out at different temperatures (80°C, 90°C and 100°C) while anode and cathode backpressures and dew point temperatures were kept unchanged. Particular attention was dedicated to the evaluation of electrode’s mass transport resistance through the adoption of both conventional and innovative limiting current measurements based on hydrogen pumping configuration 4 . The impact of a higher operating temperature was observed mainly on performance decay at high current densities that suggested the presence of additional degradation mechanisms compared to catalyst active area loss. Results obtained from limiting current measurements were in agreement with these findings, highlighting a higher rate of increase of transport resistance when the operating cell temperature increases. Hydrogen limiting currents presented a relative greater increase of the transport resistance compared to oxygen measurements, which suggests a degradation of the ionomer thin-film due to the higher impact of thin-film on the overall hydrogen transport resistance. The protocols at different temperatures were conducted on several commercial Catalyst Coated Membranes characterized by different cathode catalyst layer structures. In particular, different carbon support morphology and Pt loading were considered. High Surface Carbon showed indication of carbon corrosion formation at 90°C and 100°C, while highly graphitized carbon showed very limited differences among the tested temperatures. Materials with lower electrode thickness, related to the lower Pt loading, were tested for both carbon support morphologies and it was observed how electrode thickness impacts the rate of increase of transport resistance with respect to cathode Pt active surface. This work received support from “Progetto Permanent - Bando Mite PNRR Missione 2 Investimento 3.5 A-RSH2A_0O0012” D. A. Cullen et al., Nature Energy (2021) http://dx.doi.org/10.1038/s41560-021-00775-z. E. Colombo, A. Baricci, D. Mora, L. Guetaz, and A. Casalegno, Journal of Power Sources, 580, 233376 (2023) https://www.immortal-fuelcell.eu/index.php/activities/delivrables#wp2 T. Schuler et al., Journal of The Electrochemical Society, 166, F3020–F3031 (2019). Figure 1