In recent years, Proton Exchange Membrane Fuel Cells (PEMFCs) have gained increasing attention as a commercial option for light-duty vehicles and a promising solution for heavy-duty applications, where system design remains an active area of research 1 . Ensuring the efficient and durable operation of PEMFCs requires a comprehensive understanding of the local operating conditions within the membrane-electrode assembly (MEA). Effective numerical modelling is crucial for unravelling the complexities of local heterogeneities arising from interactions among different system components. However, there is a need for models that are both computationally efficient and physically consistent. This study develops a detailed physical model of a fuel cell system based on a typical system architecture, with a primary focus on the PEMFC stack. The model employs a 1+1D multiphase, dynamic, non-isothermal approach based on previous works 2 . It accounts for mass dynamics in channels and gas diffusion layers, as well as membrane hydration and dehydration mechanisms, incorporating the impact of two platinum oxides species on oxygen reduction reaction (ORR) kinetics 3 . Additionally, air and hydrogen feed subsystems are modelled alongside the thermal management system, which plays a critical role in heavy-duty applications. The governing equations are implemented in the MATLAB Simulink environment using Simscape libraries, significantly reducing computational time, by at least a factor of 30, compared to an in-house model developed purely in Simulink 2 . This improvement enables faster-than-real-time simulation capability. The PEMFC system model, as visible in Figure 1(a), along with control strategies, is calibrated and validated using experimental data from an online database provided by the Argonne National Laboratory, based on a commercial light-duty vehicle 4 . Further validation is performed using experimental data obtained from a heavy-duty protocol, developed within the Italian project PERMANENT, on a five-segment single-cell PEMFC hardware, shown in Figure 1(b). A reference layout for the heavy-duty fuel cell system is selected based on publicly available data, and its dynamic performance is analysed under representative driving cycle conditions. A sensitivity analysis is conducted to evaluate the impact of component design and operational strategies, with a particular focus on the thermal management system (TMS) and its control, examining their influence on local operating conditions within the MEA and their subsequent impact on durability, exploiting a semi-empirical catalyst durability model 5 . The study investigates how TMS configurations affect fuel cell performance and durability, once defined the extent of hybridization level within the energy management system. References B. James et al., Heavy-Duty Fuel Cell System Cost – 2023 , p. 1–12, (2024) https://www.hydrogen.energy.gov/docs/hydrogenprogramlibraries/pdfs/review24/24004-hd-fuel-cell-system-cost-2023.pdf?sfvrsn=70ff384f_3. F. Verducci, A. Grimaldi, E. Colombo, A. Casalegno, and A. Baricci, Renew. Energy , 234, 121194 (2024) https://linkinghub.elsevier.com/retrieve/pii/S096014812401262X. T. Jahnke, A. Baricci, C. Rabissi, and A. Casalegno, J. Electrochem. Soc. , 167, 149001 (2020) https://iopscience.iop.org/article/10.1149/1945-7111/abbfda. H. Lohse-Busch et al., Technology Assessment Of A Fuel Cell Vehicle: 2017 Toyota Mirai , Argonne, IL (United States), (2018) http://www.osti.gov/servlets/purl/1463251/. A. Grimaldi, F. Verducci, E. Colombo, A. Casalegno, and A. Baricci, ECS Meet. Abstr. , MA2023-02, 1703–1703 (2023) https://dx.doi.org/10.1149/MA2023-02371703mtgabs. Figure 1