Verya Daeichin

Verya Daeichin

Auto-generated profile, based on publicly available information

Verya Daeichin

Laboratory of Medical Imaging, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 May 2018 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
MTMingliang Tan
Mingliang Tan
CCChao Chen
Chao Chen
ZCZhao Chen
Zhao Chen
JJJovana Janjic
Jovana Janjic
VDVerya Daeichin
Verya Daeichin
MPMichiel A. P. Pertijs
Michiel A. P. Pertijs
This paper presents an area- and power-efficient application-specified integrated circuit (ASIC) for 3-D forward-looking intravascular ultrasound imaging. The ASIC is intended to be mounted at the tip of a catheter, and has a circular active area with a diameter of 1.5 mm on the top of which a 2-D array of piezoelectric transducer elements is integrated. It requires only four micro-coaxial cables to interface 64 receive (RX) elements and 16 transmit (TX) elements with an imaging system. To do so, it routes high-voltage (HV) pulses generated by the system to selected TX elements using compact HV switch circuits, digitizes the resulting echo signal received by a selected RX element locally, and employs an energy-efficient load-modulation datalink to return the digitized echo signal to the system in a robust manner. A multi-functional command line provides the required sampling clock, configuration data, and supply voltage for the HV switches. The ASIC has been realized in a 0.18-μm HV CMOS technology and consumes only 9.1 mW. Electrical measurements show 28-V HV switching and RX digitization with a 16-MHz bandwidth and 53-dB dynamic range. Acoustical measurements demonstrate successful pulse transmission and reception. Finally, a 3-D ultrasound image of a three-needle phantom is generated to demonstrate the imaging capability.

25 July 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
JJJovana Janjic
Jovana Janjic
MTMingliang Tan
Mingliang Tan
VDVerya Daeichin
Verya Daeichin
ENEmile Noothout
Emile Noothout
CCChao Chen
Chao Chen
NJNicolaas de jong
Nicolaas de jong
Intravascular ultrasound (IVUS) is an imaging modality used to visualize atherosclerosis from within the inner lumen of human arteries. Complex lesions like chronic total occlusions require forward-looking IVUS (FL-IVUS), instead of the conventional side-looking geometry. Volumetric imaging can be achieved with 2-D array transducers, which present major challenges in reducing cable count and device integration. In this work, we present an 80-element lead zirconium titanate matrix ultrasound transducer for FL-IVUS imaging with a front-end application-specific integrated circuit (ASIC) requiring only four cables. After investigating optimal transducer designs, we fabricated the matrix transducer consisting of 16 transmit (TX) and 64 receive (RX) elements arranged on top of an ASIC having an outer diameter of 1.5 mm and a central hole of 0.5 mm for a guidewire. We modeled the transducer using finite-element analysis and compared the simulation results to the values obtained through acoustic measurements. The TX elements showed uniform behavior with a center frequency of 14 MHz, a −3-dB bandwidth of 44%, and a transmit sensitivity of 0.4 kPa/V at 6 mm. The RX elements showed center frequency and bandwidth similar to the TX elements, with an estimated receive sensitivity of $3.7~\mu \text{V}$ /Pa. We successfully acquired a 3-D FL image of three spherical reflectors in water using delay-and-sum beamforming and the coherence factor method. Full synthetic-aperture acquisition can be achieved with frame rates on the order of 100 Hz. The acoustic characterization and the initial imaging results show the potential of the proposed transducer to achieve 3-D FL-IVUS imaging.

31 January 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
EVEric Verschuur
Eric Verschuur
MVMartin Verweij
Martin Verweij
VDVerya Daeichin
Verya Daeichin
NJNicolaas de jong
Nicolaas de jong
GRGuillaume Renaud
Guillaume Renaud
Transcranial ultrasound imaging (TUI) is a diagnostic modality with numerous applications, but unfortunately, it is hindered by phase aberration caused by the skull. In this article, we propose to reconstruct a transcranial B-mode image with a refraction-corrected synthetic aperture imaging (SAI) scheme. First, the compressional sound velocity of the aberrator (i.e., the skull) is estimated using the bidirectional headwave technique. The medium is described with four layers (i.e., lens, water, skull, and water), and a fast marching method calculates the travel times between individual array elements and image pixels. Finally, a delay-and-sum algorithm is used for image reconstruction with coherent compounding. The point spread function (PSF) in a wire phantom image and reconstructed with the conventional technique (using a constant sound speed throughout the medium), and the proposed method was quantified with numerical synthetic data and experiments with a bone-mimicking plate and a human skull, compared with the PSF achieved in a ground truth image of the medium without the aberrator (i.e., the bone plate or skull). A phased-array transducer (P4-1, ATL/Philips, 2.5 MHz, 96 elements, pitch $=$ 0.295 mm) was used for the experiments. The results with the synthetic signals, the bone-mimicking plate, and the skull indicated that the proposed method reconstructs the scatterers with an average lateral/axial localization error of 0.06/0.14 mm, 0.11/0.13 mm, and 1.0/0.32 mm, respectively. With the human skull, an average contrast ratio (CR) and full-width-half-maximum (FWHM) of 37.1 dB and 1.75 mm were obtained with the proposed approach, respectively. This corresponds to an improvement of CR and FWHM by 7.1 dB and 36% compared with the conventional method, respectively. These numbers were 12.7 dB and 41% with the bone-mimicking plate.

1 February 2015 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
VDVerya Daeichin
Verya Daeichin
JBJohan G. Bosch
Johan G. Bosch
ANAndrew Needles
Andrew Needles
FFF. Stuart Foster
F. Stuart Foster
ASAntonius van der Steen
Antonius van der Steen
NJNico de Jong
Nico de Jong

18 March 2021 in IEEE Access
Verified
Journal Article
Open access
RWRick Waasdorp
Rick Waasdorp
WMWinfred Mugge
Winfred Mugge
HVHendrik J. Vos
Hendrik J. Vos
JGJurriaan H. de Groot
Jurriaan H. de Groot
MVMartin Verweij
Martin Verweij
VDVerya Daeichin
Verya Daeichin
Skeletal muscles generate force, enabling movement through a series of fast electromechanical activations coordinated by the central nervous system. Understanding the underlying mechanism of such fast muscle dynamics is essential in neuromuscular diagnostics, rehabilitation medicine and sports biomechanics. The unique combination of electromyography (EMG) and ultrafast ultrasound imaging (UUI) provides valuable insights into both electrical and mechanical activity of muscle fibers simultaneously, the excitation-contraction (E-C) coupling. In this feasibility study we propose a novel non-invasive method to simultaneously track the propagation of both electrical and mechanical waves in muscles using high-density electromyography and ultrafast ultrasound imaging (5000 fps). Mechanical waves were extracted from the data through an axial tissue velocity estimator based on one-lag autocorrelation. The E-C coupling in electrically evoked twitch contractions of the Biceps Brachii in healthy participants could successfully be tracked. The excitation wave (i.e. action potential) had a velocity of 3.9 ± 0.5 ms-1 and the subsequent mechanical (i.e. contraction) wave had a velocity of 3.5 ± 0.9 ms-1. The experiment showed evidence that contracting sarcomeres that were already activated by the action potential (AP) pull on sarcomeres that were not yet reached by the AP, which was corroborated by simulated contractions of a newly developed multisegmental muscle fiber model, consisting of 500 sarcomeres in series. In conclusion, our method can track the electromechanical muscle dynamics with high spatio-temporal resolution. Ultimately, characterizing E-C coupling in patients with neuromuscular diseases (e.g. Duchenne or Becker muscular dystrophy) may assess contraction efficiency, monitor the progression of the disease, and determine the efficacy of new treatment options.

15 December 2016 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
VDVerya Daeichin
Verya Daeichin
TRTom van Rooij
Tom van Rooij
ISIlya Skachkov
Ilya Skachkov
BEBulent Ergin
Bulent Ergin
PSPatricia A. C. Specht
Patricia A. C. Specht
KKKlazina Kooiman
Klazina Kooiman
Although high-frequency ultrasound imaging is gaining attention in various applications, hardly any ultrasound contrast agents (UCAs) dedicated to such frequencies (>15 MHz) are available for contrast-enhanced ultrasound (CEUS) imaging. Moreover, the composition of the limited commercially available UCAs for high-frequency CEUS (hfCEUS) is largely unknown, while shell properties have been shown to be an important factor for their performance. The aim of our study was to produce UCAs in-house for hfCEUS. Twelve different UCA formulations A-L were made by either sonication or mechanical agitation. The gas core consisted of C 4 F 10 and the main coating lipid was either 1,2-distearoyl-sn-glycero-3-phosphocholine (DSPC; A-F formulation) or 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC; G-L formulation). Mechanical agitation resulted in UCAs with smaller microbubbles (number weighted mean diameter ~1 μm) than sonication (number weighted mean diameter ~2 μm). UCA formulations with similar size distributions but different main lipid components showed that the DPPC-based UCA formulations had higher nonlinear responses at both the fundamental and subharmonic frequencies in vitro for hfCEUS using the Vevo2100 high-frequency preclinical scanner (FUJIFILM VisualSonics, Inc.). In addition, UCA formulations F (DSPC-based) and L (DPPC-based) that were made by mechanical agitation performed similar in vitro to the commercially available Target-Ready MicroMarker (FUJIFILM VisualSonics, Inc.). UCA formulation F also performed similar to Target-Ready MicroMarker in vivo in pigs with similar mean contrast intensity within the kidney (n = 7), but formulation L did not. This is likely due to the lower stability of formulation L in vivo. Our study shows that DSPC-based microbubbles produced by mechanical agitation resulted in small microbubbles with high nonlinear responses suitable for hfCEUS imaging.