Martin Verweij

Dr. Martin Verweij

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2020 in Journal of Controlled Release
Verified
Journal Article
Open access
Inés BeekersInés Beekers
Inés Beekers
MVMerel Vegter
Merel Vegter
KLKirby Lattwein
Kirby Lattwein
FMFrits Mastik
Frits Mastik
RBRobert Beurskens
Robert Beurskens
KKKlazina Kooiman
Klazina Kooiman
Ultrasound insonification of microbubbles can locally increase vascular permeability to enhance drug delivery. To control and optimize the therapeutic potential, we need to better understand the underlying biological mechanisms of the drug delivery pathways. The aim of this in vitro study was to elucidate the microbubble-endothelial cell interaction using the Brandaris 128 ultra-high-speed camera (up to 25 Mfps) coupled to a custom-built Nikon confocal microscope, to visualize both microbubble oscillation and the cellular response. Sonoporation and opening of cell-cell contacts by single αVβ3-targeted microbubbles (n = 152) was monitored up to 4 min after ultrasound insonification (2 MHz, 100-400 kPa, 10 cycles). Sonoporation occurred when microbubble excursion amplitudes exceeded 0.7 μm. Quantification of the influx of the fluorescent model drug propidium iodide upon sonoporation showed that the size of the created pore increased for larger microbubble excursion amplitudes. Microbubble-mediated opening of cell-cell contacts occurred as a cellular response upon sonoporation and did not correlate with the microbubble excursion amplitude itself. The initial integrity of the cell-cell contacts affected the susceptibly to drug delivery, since cell-cell contacts opened more often when cells were only partially attached to their neighbors (48%) than when fully attached (14%). The drug delivery outcomes were independent of nonlinear microbubble behavior, microbubble location, and cell size. In conclusion, by studying the microbubble-cell interaction at nanosecond and nanometer resolution the relationship between drug delivery pathways and their underlying mechanisms was further unraveled. These novel insights will aid the development of safe and efficient microbubble-mediated drug delivery.

31 January 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
EVEric Verschuur
Eric Verschuur
MVMartin Verweij
Martin Verweij
VDVerya Daeichin
Verya Daeichin
NJNicolaas de jong
Nicolaas de jong
GRGuillaume Renaud
Guillaume Renaud
Transcranial ultrasound imaging (TUI) is a diagnostic modality with numerous applications, but unfortunately, it is hindered by phase aberration caused by the skull. In this article, we propose to reconstruct a transcranial B-mode image with a refraction-corrected synthetic aperture imaging (SAI) scheme. First, the compressional sound velocity of the aberrator (i.e., the skull) is estimated using the bidirectional headwave technique. The medium is described with four layers (i.e., lens, water, skull, and water), and a fast marching method calculates the travel times between individual array elements and image pixels. Finally, a delay-and-sum algorithm is used for image reconstruction with coherent compounding. The point spread function (PSF) in a wire phantom image and reconstructed with the conventional technique (using a constant sound speed throughout the medium), and the proposed method was quantified with numerical synthetic data and experiments with a bone-mimicking plate and a human skull, compared with the PSF achieved in a ground truth image of the medium without the aberrator (i.e., the bone plate or skull). A phased-array transducer (P4-1, ATL/Philips, 2.5 MHz, 96 elements, pitch $=$ 0.295 mm) was used for the experiments. The results with the synthetic signals, the bone-mimicking plate, and the skull indicated that the proposed method reconstructs the scatterers with an average lateral/axial localization error of 0.06/0.14 mm, 0.11/0.13 mm, and 1.0/0.32 mm, respectively. With the human skull, an average contrast ratio (CR) and full-width-half-maximum (FWHM) of 37.1 dB and 1.75 mm were obtained with the proposed approach, respectively. This corresponds to an improvement of CR and FWHM by 7.1 dB and 36% compared with the conventional method, respectively. These numbers were 12.7 dB and 41% with the bone-mimicking plate.

9 September 2022 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
YHYannick M. Hopf
Yannick M. Hopf
BOBoudewine W. Ossenkoppele
Boudewine W. Ossenkoppele
MSMehdi Soozande
Mehdi Soozande
ENEmile Noothout
Emile Noothout
ZCZu-Yao Chang
Zu-Yao Chang
MMichiel Pertijs
Michiel Pertijs
In this article, an application-specific integrated circuit (ASIC) for 3-D, high-frame-rate ultrasound imaging probes is presented. The design is the first to combine element-level, high-voltage (HV) transmitters and analog front-ends, subarray beamforming, and in-probe digitization in a scalable fashion for catheter-based probes. The integration challenge is met by a hybrid analog-to-digital converter (ADC), combining an efficient charge-sharing successive approximation register (SAR) first stage and a compact single-slope (SS) second stage. Application in large ultrasound imaging arrays is facilitated by directly interfacing the ADC with a charge-domain subarray beamformer, locally calibrating interstage gain errors and generating the SAR reference using a power-efficient local reference generator. Additional hardware-sharing between neighboring channels ultimately leads to the lowest reported area and power consumption across miniature ultrasound probe ADCs. A pitch-matched design is further enabled by an efficient split between the core circuitry and a periphery block, the latter including a datalink performing clock data recovery (CDR) and time-division multiplexing (TDM), which leads to a 12-fold total channel count reduction. A prototype of $8{\times }9$ elements was fabricated in a TSMC 0.18- $\mu \text{m}$ HV BCD technology and a 2-D PZT transducer matrix with a pitch of $160 \mu \text{m}$ , and a center frequency of 6 MHz was manufactured on the chip. The imaging device operates at up to 1000 volumes/s, generates 65-V transmit pulses, and has a receive power consumption of only 1.23 mW/element. The functionality has been demonstrated electrically as well as in acoustic and imaging experiments.

18 March 2021 in IEEE Access
Verified
Journal Article
Open access
RWRick Waasdorp
Rick Waasdorp
WMWinfred Mugge
Winfred Mugge
HVHendrik J. Vos
Hendrik J. Vos
JGJurriaan H. de Groot
Jurriaan H. de Groot
MVMartin Verweij
Martin Verweij
VDVerya Daeichin
Verya Daeichin
Skeletal muscles generate force, enabling movement through a series of fast electromechanical activations coordinated by the central nervous system. Understanding the underlying mechanism of such fast muscle dynamics is essential in neuromuscular diagnostics, rehabilitation medicine and sports biomechanics. The unique combination of electromyography (EMG) and ultrafast ultrasound imaging (UUI) provides valuable insights into both electrical and mechanical activity of muscle fibers simultaneously, the excitation-contraction (E-C) coupling. In this feasibility study we propose a novel non-invasive method to simultaneously track the propagation of both electrical and mechanical waves in muscles using high-density electromyography and ultrafast ultrasound imaging (5000 fps). Mechanical waves were extracted from the data through an axial tissue velocity estimator based on one-lag autocorrelation. The E-C coupling in electrically evoked twitch contractions of the Biceps Brachii in healthy participants could successfully be tracked. The excitation wave (i.e. action potential) had a velocity of 3.9 ± 0.5 ms-1 and the subsequent mechanical (i.e. contraction) wave had a velocity of 3.5 ± 0.9 ms-1. The experiment showed evidence that contracting sarcomeres that were already activated by the action potential (AP) pull on sarcomeres that were not yet reached by the AP, which was corroborated by simulated contractions of a newly developed multisegmental muscle fiber model, consisting of 500 sarcomeres in series. In conclusion, our method can track the electromechanical muscle dynamics with high spatio-temporal resolution. Ultimately, characterizing E-C coupling in patients with neuromuscular diseases (e.g. Duchenne or Becker muscular dystrophy) may assess contraction efficiency, monitor the progression of the disease, and determine the efficacy of new treatment options.

4 June 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
LWLuxi Wei
Luxi Wei
GWGeraldi Wahyulaksana
Geraldi Wahyulaksana
BMBram Meijlink
Bram Meijlink
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
ENEmile Noothout
Emile Noothout
HVHendrik J. Vos
Hendrik J. Vos
Volumetric ultrasound imaging of blood flow with microbubbles enables a more complete visualization of the microvasculature. Sparse arrays are ideal candidates to perform volumetric imaging at reduced manufacturing complexity and cable count. However, due to the small number of transducer elements, sparse arrays often come with high clutter levels, especially when wide beams are transmitted to increase the frame rate. In this study, we demonstrate with a prototype sparse array probe and a diverging wave transmission strategy, that a uniform transmission field can be achieved. With the implementation of a spatial coherence beamformer, the background clutter signal can be effectively suppressed, leading to a signal to background ratio improvement of 25 dB. With this approach, we demonstrate the volumetric visualization of single microbubbles in a tissue-mimicking phantom as well as vasculature mapping in a live chicken embryo chorioallantoic membrane.

7 July 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Moein MozaffarzadehMoein Mozaffarzadeh
Moein Mozaffarzadeh
DVDirk J. Eric Verschuur
Dirk J. Eric Verschuur
MVMartin Verweij
Martin Verweij
NJNicolaas de jong
Nicolaas de jong
GRGuillaume Renaud
Guillaume Renaud
In a recent study, we proposed a technique to correct aberration caused by the skull and reconstruct a transcranial B-mode image with a refraction-corrected synthetic aperture imaging (SAI) scheme. Given a sound speed map, the arrival times were calculated using a fast marching technique (FMT), which solves the Eikonal equation and, therefore, is computationally expensive for real-time imaging. In this article, we introduce a two-point ray tracing method, based on Fermat’s principle, for fast calculation of the travel times in the presence of a layered aberrator in front of the ultrasound probe. The ray tracing method along with the reconstruction technique is implemented on a graphical processing unite (GPU). The point spread function (PSF) in a wire phantom image reconstructed with the FMT and the GPU implementation was studied with numerical synthetic data and experiments with a bone-mimicking plate and a sagittally cut human skull. The numerical analysis showed that the error on travel times is less than 10% of the ultrasound temporal period at 2.5 MHz. As a result, the lateral resolution was not significantly degraded compared with images reconstructed with FMT-calculated travel times. The results using the synthetic, bone-mimicking plate, and skull dataset showed that the GPU implementation causes a lateral/axial localization error of 0.10/0.20, 0.15/0.13, and 0.26/0.32 mm compared with a reference measurement (no aberrator in front of the ultrasound probe), respectively. For an imaging depth of 70 mm, the proposed GPU implementation allows reconstructing 19 frames/s with full synthetic aperture (96 transmission events) and 32 frames/s with multiangle plane wave imaging schemes (with 11 steering angles) for a pixel size of $200~\mu \text{m}$ . Finally, refraction-corrected power Doppler imaging is demonstrated with a string phantom and a bone-mimicking plate placed between the probe and the moving string. The proposed approach achieves a suitable frame rate for clinical scanning while maintaining the image quality.