Ahilan Anantha Krishnan

Ahilan Anantha Krishnan

Auto-generated profile, based on publicly available information

Ahilan Anantha Krishnan

Department of Aerospace and Mechanical Engineering, University of Notre Dame, Notre Dame, 46556, IN, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2023 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
Yashar Ali BehnamYashar Ali Behnam
Yashar Ali Behnam
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
HWHayden Wilson
Hayden Wilson
Chadd ClaryChadd Clary
Chadd Clary
Contemporary total knee arthroplasty (TKA) have not fully restored natural P-F mechanics across the patient population. Previous experimental simulations have been limited in their ability to create dynamic, unconstrained, muscle-driven P-F articulation while simultaneously controlling tibiofemoral (T-F) contact mechanics. The purpose of this study was to develop and verify a novel experimental simulation and corresponding finite element model to evaluate T-F and P-F mechanics. A commercially available wear simulator was retrofit with custom fixturing to evaluate whole-knee TKA mechanics with varying patella heights during a simulated deep knee bend. A corresponding dynamic finite element model was developed to verify kinematic and kinetic predictions against experimental measurements. Patella alta reduced P-F reaction forces in early and mid-flexion, corresponding with an increase in T-F forces that indicated an increase in extensor mechanism efficiency. Due to reduced wrapping of the extensor mechanism in deeper flexion for the alta condition, peak P-F forces in flexion increased from 101% to 135% of the applied quadriceps load for baja and alta conditions, respectively. Strong agreement was observed between the experiment and model predictions with root mean square errors (RMSE) for P-F kinematics ranging from 0.8° to 3.3° and 0.7 mm to 1.4 mm. RMSE for P-F forces ranged from 7.4 N to 53.6 N. This novel experimental simulation and verified model will be a useful tool for future development of TKA implants.

28 December 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
CMCasey A. Myers
Casey A. Myers
CFClare Fitzpatrick
Clare Fitzpatrick
Chadd ClaryChadd Clary
Chadd Clary
Subject-specific hip capsule models could offer insights into impingement and dislocation risk when coupled with computer-aided surgery, but model calibration is time-consuming using traditional techniques. This study developed a framework for instantaneously generating subject-specific finite element (FE) capsule representations from regression models trained with a probabilistic approach. A validated FE model of the implanted hip capsule was evaluated probabilistically to generate a training dataset relating capsule geometry and material properties to hip laxity. Multivariate regression models were trained using 90% of trials to predict capsule properties based on hip laxity and attachment site information. The regression models were validated using the remaining 10% of the training set by comparing differences in hip laxity between the original trials and the regression-derived capsules. Root mean square errors (RMSEs) in laxity predictions ranged from 1.8° to 2.3°, depending on the type of laxity used in the training set. The RMSE, when predicting the laxity measured from five cadaveric specimens with total hip arthroplasty, was 4.5°. Model generation time was reduced from days to milliseconds. The results demonstrated the potential of regression-based training to instantaneously generate subject-specific FE models and have implications for integrating subject-specific capsule models into surgical planning software.

20 April 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
PDPhil G. Dinning
Phil G. Dinning
MHMaria A. Holland
Maria A. Holland
Purpose: Colonic motility disorders, including diarrhea-predominant irritable bowel syndrome and slow-transit constipation, impose a major clinical burden. Although high-resolution colonic manometry reveals characteristic spatiotemporal motor patterns, such as high-amplitude propagating contractions and cyclic motor pattern in healthy individuals, these patterns are often altered or absent in disease. Understanding how these patterns arise from underlying pacemaker, neural, and mechanical mechanisms is essential for improving treatment strategies. Methods: We developed a biophysical whole-colon model that integrates an Interstitial Cells of Cajal–inspired oscillator network, enteric nervous system reflexes, a pressure-gated modulation element motivated by rectosigmoid brake behavior, and a nonlinear tube law describing colon wall mechanics. The model simulates spatiotemporal pressure patterns along the colon and allows systematic variation of physiological parameters associated with pacemaker activity, neural reflex control, and distal gating. Results: A small set of parameters reproduces three illustrative motility patterns corresponding to healthy motility, diarrhea-predominant irritable bowel syndrome, and slow-transit constipation. The simulated pressure maps recapitulate key features observed in high-resolution manometry, including propagation direction, regional patterning of contractions, and case-specific changes in amplitude and coordination. Sensitivity analysis suggests that proximal excitation strength and waveform morphology strongly influence global motility metrics. Conclusion: Our study presents a simple, biophysical framework for reproducing clinically observed colonic motor patterns and exploring their disruption in disease. More broadly, the model may help interpret clinical manometry in mechanistic terms and support hypothesis-driven in silico studies of colonic motility disorders.

14 September 2026 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
SRShreya Raghavan
Shreya Raghavan
MHMaria A. Holland
Maria A. Holland

2 November 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
Yashar Ali BehnamYashar Ali Behnam
Yashar Ali Behnam
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
RLRenate List
Renate List
Chadd ClaryChadd Clary
Chadd Clary
The mechanism and boundary conditions used to drive experimental joint simulators have historically adopted standardized profiles developed from healthy, non-total knee arthroplasty (TKA) patients. The purpose of this study was to use implant-specific in vivo knee kinematics to generate physiologically relevant boundary conditions used in the evaluation of cadaveric knees post-TKA. Implant-specific boundary conditions were generated by combining in vivo fluoroscopic kinematics, musculoskeletal modeling-generated quadriceps loading, and telemetric knee compressive loading during activities of daily living (ADL) to dynamically drive a servo-hydraulic knee joint simulator. Ten cadaveric knees were implanted with the same TKA components and mounted in the knee simulator to verify the resulting load profiles against reported fluoroscopic kinematics and loading captured by an ultra-congruent telemetric knee implant. The cadaveric simulations resulted in implant-specific boundary conditions, which accurately recreate the in vivo performance of the like-implanted knee, with Root Mean Square Error (RMSE) in femoral low point kinematics below 2.0 mm across multiple activities of daily living. This study demonstrates the viability of in vivo fluoroscopy as the source of relevant boundary conditions for a novel knee loading apparatus, enabling dynamic cadaveric knee loading that aligns with clinical observations to improve the preclinical development of TKA component design.

25 September 2026 in bioRxiv
Verified
Preprint
Open access
PDF file
AKAhilan Anantha Krishnan
Ahilan Anantha Krishnan
MAMasah Abubaker
Masah Abubaker
MHMaria A. Holland
Maria A. Holland
Fibrotic strictures are among the most disabling complications of Crohn’s disease, permanently narrowing the bowel and impairing motility, yet no approved therapy reverses them. Chronic inflammation alters pacemaker-network coupling, smooth-muscle excitability, and calcium-dependent contractility, while fibrosis thickens the bowel wall, narrows the lumen, and changes tissue mechanics. The relative contributions of these coupled electrical, contractile, and structural alterations to motility loss remain unclear. To address this gap, we develop an integrated electromechanical finite-element framework for fibrostenosing Crohn’s disease that couples a fibrosis-driven growth model with a FitzHugh-Nagumo electromechanical model. A full-factorial 2 5 design of experiments is used to quantify the relative effects of electrical diffusivity, excitation threshold, peak active stress, wall stiffness, and hypertrophic remodeling on cyclic lumen-volume deformation. Motility is quantified by the standard deviation of lumen volume over one contraction cycle. Within the parameter ranges examined, increased wall stiffness emerged as the dominant contributor to motility loss, followed by impaired smooth-muscle contractility. Changes in excitation threshold, hypertrophic remodeling, and electrical diffusivity produced substantially smaller effects. Pairwise interactions were small relative to the dominant main effects, indicating that the mechanisms contributed largely through their individual effects. Our findings suggest that limiting wall stiffening while preserving smoothmuscle contractile function may provide a therapeutic strategy for maintaining intestinal motility in fibrostenosing Crohn’s disease.