This paper examines the effects of occupants’ behaviour on the thermal environment in air-conditioned rooms. Typical occupants’ behaviours were determined from survey results in the hot summers and cold winters region of China. The temperature setpoint, intermittent operation and door opening were determined as influencing factors in a theoretical model for maintaining thermal comfort with minimal energy consumption. The concepts of the temperature change index and characteristic temperature were introduced to predict the relationship between the indoor thermal environment and occupants’ behaviour. The model was validated with empirical experiments and numerical simulations. The results indicated that continuous opening of doors and windows in air-conditioned rooms would increase the energy consumption that is needed to maintain a desirable indoor thermal environment. The average indoor temperature at 25°C setpoint heating temperature with the door open at 90° was found equal to the average indoor setpoint temperature of 22°C with the door open at 45°. The relative effects of the tested occupants’ behaviours were also evaluated.
Part load ratio is often observed in real operations of airport terminal cooling system. This phenomenon is more obvious during the COVID-19 pandemic, as sudden flight restrictions impacting cooling demand are widely adopted in hub airport terminals. This research aims to propose optimal strategies of multi-chiller in airport terminals based on cooling load characteristics modeling, to tackle the aforementioned issues. Numerical experiments based on a real-world Chinese airport terminal are conducted to validate the proposed method. The results show that an average cooling load drop of 30% is observed from scenario of normal flight before COVID-19 to scenario of COVID-19 Period flight, and the average cooling load drop reaches to 44% from scenario of busy flight before COVID-19 to scenario of COVID-19 Period flight. The results also reflect that cooling load presents synchronous trend with passenger flow, but presents asynchronous trend with outdoor temperature. The influence of outdoor temperature on cooling demand delays due to building envelops. It indicates that simple superimposition according to passenger flow change for chiller operation number is reliable, efficient and effective, but is not suitable for outdoor temperature change. The findings are helpful to develop optimal strategies for further real-time control of multi-chiller.