Bryan Sanchez

Bryan Sanchez

Auto-generated profile, based on publicly available information

Bryan Sanchez

Instituto de Investigaciones en Ciencias Biomédicas, Universidad Ricardo Palma, Lima 15039, Peru

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

31 October 2024 in Revista de la Facultad de Medicina Humana
Verified
Journal Article
Open access
PDF file
Adrian Mijail NacarinoAdrian Mijail Nacarino
Adrian Mijail Nacarino
ALAnderson La-Rosa
Anderson La-Rosa
BSBryan Sanchez
Bryan Sanchez
JCJose Cornejo
Jose Cornejo
MVMariela Vargas
Mariela Vargas
RPRicardo Palomares
Ricardo Palomares
La realidad mixta (RM) se sitúa entre la realidad aumentada (RA) y la realidad virtual (RV), combinando elementos de ambas para ofrecer una experiencia interactiva más avanzada. La RV crea entornos completamente virtuales e inmersivos que pueden involucrar múltiples sentidos, mientras que la RA superpone datos virtuales sobre el entorno real, sin una interacción profunda (1). En contraste, la RM integra datos virtuales en el entorno real de manera que estos interactúan en tiempo real, proporcionando una experiencia más inmersiva y funcional (2,3).

29 May 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
Adrian Mijail NacarinoAdrian Mijail Nacarino
Adrian Mijail Nacarino
BSBryan Sanchez
Bryan Sanchez
SCSandra Charapaqui
Sandra Charapaqui
RCRenzo Charapaqui
Renzo Charapaqui
RMRenzo R. Maldonado-Gómez
Renzo R. Maldonado-Gómez
JCJorge Cornejo
Jorge Cornejo
Stroke is the second leading cause of death globally and a major contributor to lower-limb disability, affecting gait, balance, and functional independence in elderly populations. While robot-assisted rehabilitation has demonstrated effectiveness in motor recovery, access remains limited due to high costs and geographic barriers, particularly in Latin America. This study presents ExoKnee, a low-cost knee exoskeleton designed through biomimetic principles and 3D-printed fabrication as a proof-of-concept device targeting gait rehabilitation in elderly adults. The system integrates a single-degree-of-freedom pneumatic actuator controlled by electromyography (EMG) signals from the quadriceps muscle, enabling knee flexion and extension (90° to 180°). The design was evaluated through finite element analysis and dynamic simulations in MATLAB/Simulink R2024a under constant, stepwise, and sinusoidal reference inputs in a digital-twin environment. Expert validation using the Content Validity Coefficient yielded a mean score of 0.8747, reflecting preliminary expert agreement on the conceptual design’s coherence and relevance. The prototype demonstrated controlled movements through a 6-bar pneumatic system with EMG-triggered relay activation, validated at the proof-of-concept level through simulation and single-subject threshold calibration. ExoKnee addresses critical gaps by offering an anthropometrically informed, biosignal-driven, and locally manufacturable rehabilitation platform for low- and middle-income countries, pending clinical validation. Future work will focus on clinical trials and adaptive EMG control strategies.

9 October 2025
Verified
Conference Paper
Closed access
Adrian Mijail NacarinoAdrian Mijail Nacarino
Adrian Mijail Nacarino
BSBryan Sanchez
Bryan Sanchez
RPRicardo Palomares
Ricardo Palomares
FVFreedy Sotelo Valer
Freedy Sotelo Valer
Jose Cornejo, Ph.D.Jose Cornejo, Ph.D.
Jose Cornejo, Ph.D.
MVMariela Vargas
Mariela Vargas
This paper presents ExoKnee, a pneumatic knee exoskeleton to provide mobility support for elderly adults. The system was designed using standardized anthropometric measurements (ISO 7250-1:2017) to ensure proper ergonomic fit. The device integrated a pneumatic actuator (FESTO DSNU-S-12-50-P-A-MQ); with a control system based on electromyography (EMG) signals, which allowed the execution of flexion and extension movements; subsequently, a biomechanical model was developed in OpenSim from which realistic joint kinematics data were extracted, which guided dynamic simulations in MATLAB/Simulink. The mechanical structure was validated through Computer-Aided Design (CAD) and the kinematic behavior was evaluated in CoppeliaSim, simulating a rehabilitation environment with a virtual patient performing repetitive exercises. Finally, a functional prototype was manufactured through 3D printing; which achieved a range of motion from 109° to 175°, with an absolute error of 8.16%; altogether, ExoKnee stands out for its accessible, modular, and anthropometrically adapted design; therefore, it is proposed as an inclusive technology for walking support in elderly adults.