Miguel Bhagubai

Mr. Miguel Bhagubai

KU Leuven

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
ASAnne Schwarz
Anne Schwarz
MBMiguel Bhagubai
Miguel Bhagubai
GWGerjan Wolterink
Gerjan Wolterink
JHJeremia P. O. Held
Jeremia P. O. Held
ALAndreas Luft
Andreas Luft
PVPeter Veltink
Peter Veltink
Precise and objective assessments of upper limb movement quality after strokes in functional task conditions are an important prerequisite to improve understanding of the pathophysiology of movement deficits and to prove the effectiveness of interventions. Herein, a wearable inertial sensing system was used to capture movements from the fingers to the trunk in 10 chronic stroke subjects when performing reach-to-grasp activities with the affected and non-affected upper limb. It was investigated whether the factors, tested arm, object weight, and target height, affect the expressions of range of motion in trunk compensation and flexion-extension of the elbow, wrist, and finger during object displacement. The relationship between these metrics and clinically measured impairment was explored. Nine subjects were included in the analysis, as one had to be excluded due to defective data. The tested arm and target height showed strong effects on all metrics, while an increased object weight showed effects on trunk compensation. High inter- and intrasubject variability was found in all metrics without clear relationships to clinical measures. Relating all metrics to each other resulted in significant negative correlations between trunk compensation and elbow flexion-extension in the affected arm. The findings support the clinical usability of sensor-based motion analysis.

3 February 2023 in Epilepsia
Verified
Journal Article
Open access
JMJaiver Macea
Jaiver Macea
MBMiguel Bhagubai
Miguel Bhagubai
VBVictoria Broux
Victoria Broux
MVMaarten De Vos
Maarten De Vos
WPWim Van Paesschen
Wim Van Paesschen
Objective: The aim is to report the performance of an electroencephalogram (EEG) seizure‐detector algorithm on data obtained with a wearable device (WD) in patients with focal refractory epilepsy and their experience.Methods: Patients used a WD, the Sensor Dot (SD), to measure two channels of EEG using dry electrode patches during presurgical evaluation and at home for up to 8 months. An automated seizure detection algorithm flagged EEG regions with possible seizures, which we reviewed to evaluate the algorithm's diagnostic yield. In addition, we collected data on usability, side effects, and patient satisfaction with an electronic seizure diary application (Helpilepsy).Results: Sixteen inpatients used the SD for up to 5 days and had 21 seizures. Sixteen outpatients used the device for up to 8 months and reported 101 focal impaired awareness seizures during the periods selected for analysis. Focal seizure detection sensitivity based on behind‐the‐ear EEG was 52% in inpatients and 23% in outpatients. False detections/h, positive predictive value (PPV), and F1 scores were 7.13%, .11%, and .002% for inpatients and 7.77%, .04%, and .001% for outpatients. Artifacts and low signal quality contributed to poor performance metrics. The seizure detector identified 19 nonreported seizures during sleep, when the signal quality was better. Regarding patients' experience, the likelihood of using the device at 6 months was 62%, and side effects were the main reason for dropping out. Finally, daily and monthly questionnaire completion rates were 33% and 65%, respectively.Significance: Focal seizure detection sensitivity based on behind‐the‐ear EEG was 52% in inpatients and 23% in outpatients, with high false alarm rates and low PPV and F1 scores. This unobtrusive wearable seizure detection device was well received but had side effects. The current workflow and low performance limit its implementation in clinical practice. We suggest different steps to improve these performance metrics and patient experience.

20 April 2023 in Bioengineering
Verified
Journal Article
Open access
PDF file
MBMiguel Bhagubai
Miguel Bhagubai
KVKaat Vandecasteele
Kaat Vandecasteele
LSLauren Swinnen
Lauren Swinnen
JMJaiver Macea
Jaiver Macea
CCChristos Chatzichristos
Christos Chatzichristos
WPWim Van Paesschen
Wim Van Paesschen
Long-term home monitoring of people living with epilepsy cannot be achieved using the standard full-scalp electroencephalography (EEG) coupled with video. Wearable seizure detection devices, such as behind-the-ear EEG (bte-EEG), offer an unobtrusive method for ambulatory follow-up of this population. Combining bte-EEG with electrocardiography (ECG) can enhance automated seizure detection performance. However, such frameworks produce high false alarm rates, making visual review necessary. This study aimed to evaluate a semi-automated multimodal wearable seizure detection framework using bte-EEG and ECG. Using the SeizeIT1 dataset of 42 patients with focal epilepsy, an automated multimodal seizure detection algorithm was used to produce seizure alarms. Two reviewers evaluated the algorithm’s detections twice: (1) using only bte-EEG data and (2) using bte-EEG, ECG, and heart rate signals. The readers achieved a mean sensitivity of 59.1% in the bte-EEG visual experiment, with a false detection rate of 6.5 false detections per day. Adding ECG resulted in a higher mean sensitivity (62.2%) and a largely reduced false detection rate (mean of 2.4 false detections per day), as well as an increased inter-rater agreement. The multimodal framework allows for efficient review time, making it beneficial for both clinicians and patients.

15 July 2025 in Scientific Data
Verified
Journal Article
Open access
PDF file
MBMiguel Bhagubai
Miguel Bhagubai
CCChristos Chatzichristos
Christos Chatzichristos
LSLauren Swinnen
Lauren Swinnen
JMJaiver Macea
Jaiver Macea
JZJingwei Zhang
Jingwei Zhang
MVMaarten De Vos
Maarten De Vos
The increasing technological advancements towards miniaturized physiological measuring devices have enabled continuous monitoring of epileptic patients outside of specialized environments. The large amounts of data that can be recorded with such devices hold significant potential for developing automated seizure detection frameworks. In this work, we present SeizeIT2, the first open dataset of wearable data recorded in patients with focal epilepsy. The dataset comprises more than 11,000 hours of multimodal data, including behind-the-ear electroencephalography, electrocardiography, electromyography and movement (accelerometer and gyroscope) data. The dataset contains 883 focal seizures recorded from 125 patients across five different European Epileptic Monitoring Centers. We present a suggestive training/validation split to propel the development of AI methodologies for seizure detection, as well as two benchmark approaches and evaluation metrics. The dataset can be accessed on OpenNeuro and is stored in Brain Imaging Data Structure (BIDS) format.

11 December 2023 in Epilepsia
Verified
Journal Article
Open access
LSLauren Swinnen
Lauren Swinnen
CCChristos Chatzichristos
Christos Chatzichristos
MBMiguel Bhagubai
Miguel Bhagubai
VBVictoria Broux
Victoria Broux
NZNicolas Zabler
Nicolas Zabler
WPWim Van Paesschen
Wim Van Paesschen
Objective: Home monitoring of 3‐Hz spike–wave discharges (SWDs) in patients with refractory absence epilepsy could improve clinical care by replacing the inaccurate seizure diary with objective counts. We investigated the use and performance of the Sensor Dot (Byteflies) wearable in persons with absence epilepsy in their home environment.Methods: Thirteen participants (median age = 22 years, 11 female) were enrolled at the university hospitals of Leuven and Freiburg. At home, participants had to attach the Sensor Dot and behind‐the‐ear electrodes to record two‐channel electroencephalogram (EEG), accelerometry, and gyroscope data. Ground truth annotations were created during a visual review of the full Sensor Dot recording. Generalized SWDs were annotated if they were 3 Hz and at least 3 s on EEG. Potential 3‐Hz SWDs were flagged by an automated seizure detection algorithm, (1) using only EEG and (2) with an additional postprocessing step using accelerometer and gyroscope to discard motion artifacts. Afterward, two readers (W.V.P. and L.S.) reviewed algorithm‐labeled segments and annotated true positive detections. Sensitivity, precision, and F1 score were calculated. Patients had to keep a seizure diary and complete questionnaires about their experiences.Results: Total recording time was 394 h 42 min. Overall, 234 SWDs were captured in 11 of 13 participants. Review of the unimodal algorithm‐labeled recordings resulted in a mean sensitivity of .84, precision of .93, and F1 score of .89. Visual review of the multimodal algorithm‐labeled segments resulted in a similar F1 score and shorter review time due to fewer false positive labels. Participants reported that the device was comfortable and that they would be willing to wear it on demand of their neurologist, for a maximum of 1 week or with intermediate breaks.Significance: The Sensor Dot improved seizure documentation at home, relative to patient self‐reporting. Additional benefits were the short review time and the patients' device acceptance due to user‐friendliness and comfortability.

7 December 2020 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
MBMiguel Bhagubai
Miguel Bhagubai
GWGerjan Wolterink
Gerjan Wolterink
ASAnne Schwarz
Anne Schwarz
JHJeremia P. O. Held
Jeremia P. O. Held
BBBert-Jan F. Van Beijnum
Bert-Jan F. Van Beijnum
PVPeter Veltink
Peter Veltink
Abstract Background: Stroke is one of the main causes of disability in the world, causing loss of motor function on mainly one side of the body. A proper assessment of motor function is required to help to direct and evaluate therapy. Assessment is currently performed by therapists using observer-based standardized clinical assessment protocols. Sensor-based technologies can be used to objectively quantify the presence and severity of motor impairments in stroke patients. Methods: In this work, a minimally obstructive distributed inertial sensing system, intended to measure kinematics of the upper extremity, was developed and tested in a pilot study, where 10 chronic stroke subjects performed the arm-related tasks from the Fugl-Meyer Assessment protocol with the affected and non-affected side. Results: The pilot study showed that the developed distributed measurement system was adequately sensitive to show significant differences in stroke subjects’ arm postures between the affected and non-affected side. The presence of pathological synergies can be analysed using the measured joint angles of the upper limb segments, that describe the movement patterns of the subject. Conclusion: Features measured by the system vary from the assessed FMA-UE sub-score showing its potential to provide more detailed clinical information.