Martina Moglioni

Martina Moglioni

Auto-generated profile, based on publicly available information

Martina Moglioni

GSI Helmholtz Centre for Heavy Ion Research GmbH, Darmstadt, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2024 in Physica Medica
Verified
Journal Article
Closed access
AKAafke Christine Kraan
Aafke Christine Kraan
FSFilippo Susini
Filippo Susini
MMMartina Moglioni
Martina Moglioni
GBGiuseppe Battistoni
Giuseppe Battistoni
DBDavide Bersani
Davide Bersani
MBMaria Giuseppina Bisogni
Maria Giuseppina Bisogni

15 March 2024 in Physica Medica
Verified
Journal Article
Open access
AKAafke Christine Kraan
Aafke Christine Kraan
MMMartina Moglioni
Martina Moglioni
GBGiuseppe Battistoni
Giuseppe Battistoni
DBDavide Bersani
Davide Bersani
ABAndrea Berti
Andrea Berti
MBMaria Giuseppina Bisogni
Maria Giuseppina Bisogni
Goal: In-beam Positron Emission Tomography (PET) is a technique for in -vivo non-invasive treatment monitoring for proton therapy. To detect anatomical changes in patients with PET, various analysis methods exist, but their clinical interpretation is problematic. The goal of this work is to investigate whether the gamma-index analysis, widely used for dose comparisons, is an appropriate tool for comparing in-beam PET distributions. Focusing on a head-and-neck patient, we investigate whether the gamma-index map and the passing rate are sensitive to progressive anatomical changes. Methods/materials: We simulated a treatment course of a proton therapy patient using FLUKA Monte Carlo simulations. Gradual emptying of the sinonasal cavity was modeled through a series of artificially modified CT scans. The in-beam PET activity distributions from three fields were evaluated, simulating a planar dual head geometry. We applied the 3D -gamma evaluation method to compare the PET images with a reference image without changes. Various tolerance criteria and parameters were tested, and results were compared to the CT-scans. Results: Based on 210 MC simulations we identified appropriate parameters for the gamma-index analysis. Tolerance values of 3 mm/3% and 2 mm/2% were suited for comparison of simulated in-beam PET distributions. The gamma passing rate decreased with increasing volume change for all fields. Conclusion: The gamma-index analysis was found to be a useful tool for comparing simulated in-beam PET images, sensitive to sinonasal cavity emptying. Monitoring the gamma passing rate behavior over the treatment course is useful to detect anatomical changes occurring during the treatment course.

13 April 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
PDF file
ABAndreas Bückner
Andreas Bückner
MMMartina Moglioni
Martina Moglioni
UWUli Weber
Uli Weber
LVLennart Volz
Lennart Volz
OSOlga Sokol
Olga Sokol
Daria BoscoloDaria Boscolo
Daria Boscolo
Objective: Accurate estimation of tissue stopping power ratios (SPR) from computed tomography (CT) data is essential in charged particle therapy (CPT), yet it remains a major source of range uncertainties. While various SPR calibration methods have been developed for clinical CT scanners, they are not tailored to cone beam type Micro CT scanners commonly used in pre-clinical studies involving small animals. This work aims to assess how different clinical SPR calibration methods influence range predictions in small animal CPT pre-clinical trials, evaluated at both the voxel and organ levels. Approach: A small animal calibration phantom was imaged with a Micro CT at X-ray tube voltages between 45 kV and 70 kV. The images were used in two single energy (SECT), a stoichiometric and a simplified method, and one stoichiometric dual energy (DECT) calibration method. The accuracy of SPR predictions for each method was evaluated using simulated CT images of murine head, thorax, and abdomen virtual phantoms derived from in vivo data. Main results: Both SECT methods were found to yield comparable accuracy in the head and abdomen areas. Root mean squared (RMS) errors to the nominal SPR values were found to be 5.04% and 4.22% in the head phantom and 2.31% and 2.61% in the abdomen phantom, for the stoichiometric and simplified SECT method, respectively. RMS errors in the lung phantom were found to be 16.42% and 35.80%. The stoichiometric DECT method was found to improve accuracy in the lung phantom to 12.37% while in the head phantom it achieved 19.37% and in the abdomen 6.42%. Significance: This is the first report of treatment plan agnostic low-kV Micro CT SPR calibration accuracy. It can provide a reference for expected SPR and range uncertainties in pre-clinical CPT trials.

15 March 2023 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
MMMartina Moglioni
Martina Moglioni
AKA.C. Kraan
A.C. Kraan
ABA. Berti
A. Berti
Pietro CarraPietro Carra
Pietro Carra
PCP. Cerello
P. Cerello
MBMaria Giuseppina Bisogni
Maria Giuseppina Bisogni

13 March 2024 in Physics in Medicine & Biology
Verified
Journal Article
Open access
MMMartina Moglioni
Martina Moglioni
Pietro CarraPietro Carra
Pietro Carra
SASilvia Arezzini
Silvia Arezzini
NBNicola Belcari
Nicola Belcari
DBDavide Bersani
Davide Bersani
Giancarlo SportelliGiancarlo Sportelli
Giancarlo Sportelli
Objective. This study addresses a fundamental limitation of in-beam positron emission tomography (IB-PET) in proton therapy: the lack of direct anatomical representation in the images it produces. We aim to overcome this shortcoming by pioneering the application of deep learning techniques to create synthetic control CT images (sCT) from combining IB-PET and planning CT scan data. Approach. We conducted simulations involving six patients who underwent irradiation with proton beams. Leveraging the architecture of a visual transformer (ViT) neural network, we developed a model to generate sCT images of these patients using the planning CT scans and the inter-fractional simulated PET activity maps during irradiation. To evaluate the model’s performance, a comparison was conducted between the sCT images produced by the ViT model and the authentic control CT images—serving as the benchmark. Main results. The structural similarity index was computed at a mean value across all patients of 0.91, while the mean absolute error measured 22 Hounsfield Units (HU). Root mean squared error and peak signal-to-noise ratio values were 56 HU and 30 dB, respectively. The Dice similarity coefficient exhibited a value of 0.98. These values are comparable to or exceed those found in the literature. More than 70% of the synthetic morphological changes were found to be geometrically compatible with the ones reported in the real control CT scan. Significance. Our study presents an innovative approach to surface the hidden anatomical information of IB-PET in proton therapy. Our ViT-based model successfully generates sCT images from inter-fractional PET data and planning CT scans. Our model’s performance stands on par with existing models relying on input from cone beam CT or magnetic resonance imaging, which contain more anatomical information than activity maps.