View All Publications
6 October 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TLTiangang Long
Tiangang Long
CJChangqing Jiang
Changqing Jiang
WSWanxuan Sang
Wanxuan Sang
YGYiyuan Gu
Yiyuan Gu
JDJianqi Ding
Jianqi Ding
LLLuming Li
Luming Li
Radio frequency (RF)-induced heating associated with medical implants is a critical concern when performing a magnetic resonance imaging (MRI) scan. The purpose of this study is to construct a “digital twin” of RF coil integrated in an MRI scanner by $B_{1}^{+}$ map matching, reproducing the physical electromagnetic (EM) field, allowing it to be a qualified test environment for heating evaluations. $B_{1}^{+}$ map inside an American Society for Testing Material (ASTM) phantom with various positions was used to characterize the physical EM field. A loaded tuned two-port birdcage body coil model was established to generate the numerical EM field and optimized to minimize the difference between the measured and simulated fields, which was quantified by “mean symmetric mean absolute percentage error” (mSMAPE). The amplitude of the simulated field was normalized to MR sequence labeling. Finally, the average specific absorption rate (SAR) inside the ASTM phantom was measured in a calorimetry experiment and compared to simulation one heated by the pre-established coil. A heating experiment was performed on an insulated cable to further validate the established test environment. The impact of excitation parameters and the port location was investigated. mSMAPE of the optimized field was less than 10%. The difference between the simulated and measured average SAR was 8.5%. $R^{2}$ for the linear regression of the temperature rise and predicted power deposition using the optimized field was 0.993. The digital twin was successfully constructed and verified a sufficiently accurate description of the physical field. The established construction method of the digital twin provides a handy choice for building RF test environment and may create more possibilities for the development of this area.

11 September 2023
Verified
Conference Paper
Closed access
TLTiangang Long
Tiangang Long
CJChangqing Jiang
Changqing Jiang
LLLuming Li
Luming Li
Magnetic resonance imaging and active implantable medical devices are both powerful tools for neuroscience research and their interaction poses potential safety concerns to patients. Radiofrequency-induced heating is the most pernicious and complex issue. The electrode tip region is the main heating site. Meanwhile, the electrode also affects the electromagnetic model as well as its measurement process of the active implantable medical device. However, the only parameter used to evaluate the electrode influence is the tip impedance. In this study, we analyzed the radiofrequency-induced heating evaluation process and defined the tip scattered field generated when fed by unit voltage excitation as the electrode sensitivity. It helps us determine the energy absorbed by the tip electrode during the electromagnetic model measurement process. Electrode sensitivity provides a new dimension for radiofrequency-induced heating study.

31 July 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TLTiangang Long
Tiangang Long
CJChangqing Jiang
Changqing Jiang
QYQunran Yuan
Qunran Yuan
WSWanxuan Sang
Wanxuan Sang
XLXuesong Luo
Xuesong Luo
LLLuming Li
Luming Li
The transfer function (TF) of a medical implant is critical for radiofrequency (RF)-induced heating evaluation during MRI scans. Conventionally, the calibration and validation of the TF are intertwined processes that rely on RF exposure experiments. This coupling can result in unvalidated scale factors and raise safety concerns for patients. To address this issue, we introduce the translational excitation strategy (TES), a method for independently measuring the scaled TF based on the principles of the induction and reciprocity theorems. TES allows the RF exposure experiment to serve as an independent validation step for the TF. We present both numerical simulations and experimental results to demonstrate the validity of this method. Moreover, TES enhances the efficiency of TF acquisition, offering a pioneering platform for advancing studies on the electromagnetic models of implants.

20 June 2024 in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
Verified
Journal Article
Closed access
TLTiangang Long
Tiangang Long
CJChangqing Jiang
Changqing Jiang
LLLuming Li
Luming Li
Radiofrequency-induced heating represents a significant and intricate challenge during the combined use of magnetic resonance imaging and active implantable medical devices. The coupling of the transfer function (TF) determination process and radiofrequency (RF) exposure experiment is a perennial problem in the field. In this study, the tip electrode was separated from the lead and numerically modeled for analysis. The current induced at the electrode in the TF measurement scenario was estimated by analyzing the electromagnetic (EM) fields near the electrode. The magnitude of TF was calibrated according to the estimated current source. The tip response under RF exposure is independently predicted with an error of less than 10% using the obtained scaled TF in simulation studies. Near-electrode EM fields analysis introduces a novel perspective in RF-induced heating evaluation study.