6 October 2022 in IEEE Transactions on Instrumentation and Measurement
Radio frequency (RF)-induced heating associated with medical implants is a critical concern when performing a magnetic resonance imaging (MRI) scan. The purpose of this study is to construct a “digital twin” of RF coil integrated in an MRI scanner by $B_{1}^{+}$ map matching, reproducing the physical electromagnetic (EM) field, allowing it to be a qualified test environment for heating evaluations. $B_{1}^{+}$ map inside an American Society for Testing Material (ASTM) phantom with various positions was used to characterize the physical EM field. A loaded tuned two-port birdcage body coil model was established to generate the numerical EM field and optimized to minimize the difference between the measured and simulated fields, which was quantified by “mean symmetric mean absolute percentage error” (mSMAPE). The amplitude of the simulated field was normalized to MR sequence labeling. Finally, the average specific absorption rate (SAR) inside the ASTM phantom was measured in a calorimetry experiment and compared to simulation one heated by the pre-established coil. A heating experiment was performed on an insulated cable to further validate the established test environment. The impact of excitation parameters and the port location was investigated. mSMAPE of the optimized field was less than 10%. The difference between the simulated and measured average SAR was 8.5%. $R^{2}$ for the linear regression of the temperature rise and predicted power deposition using the optimized field was 0.993. The digital twin was successfully constructed and verified a sufficiently accurate description of the physical field. The established construction method of the digital twin provides a handy choice for building RF test environment and may create more possibilities for the development of this area.
7 November 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Deep brain stimulation (DBS) is an effective treatment for neurological disorders, and accurately reconstructing the DBS lead trajectories is crucial for MRI compatibility assessment and surgical planning. This paper presents a novel fully automated framework for reconstructing DBS lead trajectories from postoperative CT images. The leads were first segmented by thresholding, but would be fused together somewhere. Mean curvature analysis of multi-layer CT number isosurfaces was introduced to effectively address lead fusion, due to the different topological characteristics of the isosurfaces in and out of the fusion regions. The position of electrode contacts was determined through morphological analysis to get the starting point and the initial direction for trajectory tracking. The next trajectory point was derived by calculating the weighted average coordinates of the candidate points, using the distance from the current estimated trajectory and the CT number as weights. This method has demonstrated high accuracy and efficiency, successfully and automatically reconstructing complex bilateral trajectories for 13 patient cases in less than 10 minutes with errors less than 1 mm. This work overcomes the limitations of existing semi-automatic techniques that require extensive manual intervention. It paves the way for optimizing DBS lead trajectory to reduce tissue heating and image artifacts, which will contribute to neuroimaging studies and improve clinical outcomes. Code for our proposed algorithm is publicly available on Github.
31 July 2024 in IEEE Transactions on Instrumentation and Measurement
The transfer function (TF) of a medical implant is critical for radiofrequency (RF)-induced heating evaluation during MRI scans. Conventionally, the calibration and validation of the TF are intertwined processes that rely on RF exposure experiments. This coupling can result in unvalidated scale factors and raise safety concerns for patients. To address this issue, we introduce the translational excitation strategy (TES), a method for independently measuring the scaled TF based on the principles of the induction and reciprocity theorems. TES allows the RF exposure experiment to serve as an independent validation step for the TF. We present both numerical simulations and experimental results to demonstrate the validity of this method. Moreover, TES enhances the efficiency of TF acquisition, offering a pioneering platform for advancing studies on the electromagnetic models of implants.