Mengyue Xu

Mengyue Xu

Auto-generated profile, based on publicly available information

Mengyue Xu

School of Electrical Engineering and Automation, Wuhan University, Wuhan, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XDXiaoguang Diao
Xiaoguang Diao
FLFei Liu
Fei Liu
YSYuan Song
Yuan Song
MXMengyue Xu
Mengyue Xu
YZYizhan Zhuang
Yizhan Zhuang
XZXiaoming Zha
Xiaoming Zha
Flexible DC distribution networks have been widely developed because of their advantages of high efficiency, low cost, and easy access to renewable energy. However, as distribution networks have more ends than the two-terminal transmission line, it is more challenging to protect them and locate their faults. Therefore, this paper proposes a modified T-source circuit breaker to protect against DC faults. Based on the proposed circuit breaker, an integral fault location method using double-terminal asynchronous data is proposed. The accuracy of the algorithm is not affected by the fault resistance. There are no differential terms in the algorithm, which greatly reduces the sensitivity to noise. The integral algorithm can remain steady when the voltage and current are zero in oscillation and attenuation periods. This constitutes the main contribution of this paper. Finally, it is verified by simulation and experiment that the proposed circuit breaker can isolate the power source within a short time in the typical DC distribution network. Under a noise of 30 dB for simulation, the location error of the proposed algorithm is <0.4% when the fault resistance is 0.5 Ω–500 Ω.

7 October 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
XDXiaoguang Diao
Xiaoguang Diao
FLFei Liu
Fei Liu
YSYuan Song
Yuan Song
MXMengyue Xu
Mengyue Xu
YZYizhan Zhuang
Yizhan Zhuang
XZXiaoming Zha
Xiaoming Zha
The low voltage DC distribution networks are emerging as a great development trend for their flexible access to photovoltaic energy. However, there is no mature DC circuit breaker to protect DC fault. T-source circuit breakers can quickly and automatically cut off a fault current in a very short time. Compared with Z-source circuit breakers, T-source circuit breakers have greater advantages of zero reflected current, common ground, and capability of low-pass filtering. However, as a result of the high power loss of semiconductor devices, transmission efficiency is reduced. Therefore, this paper proposes a new efficient bidirectional T-source circuit breaker. The number of semiconductor devices that conduct in steadystate is reduced and therefore the on-state loss is reduced by more than 40% compared to the existing bidirectional T-source circuit breakers. The new circuit breaker can be manually turned off by reusing the capacitors. The soft starting circuit is also integrated into the circuit breaker. Finally, it is verified by simulation and experiment that the new circuit breaker has the capabilities of fault clearing, manual tripping, and soft starting.

21 March 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XDXiaoguang Diao
Xiaoguang Diao
FLFei Liu
Fei Liu
YSYuan Song
Yuan Song
MXMengyue Xu
Mengyue Xu
YZYizhan Zhuang
Yizhan Zhuang
XZXiaoming Zha
Xiaoming Zha
The multiport dc/dc converter with input independent output series structure is simple and efficient for photovoltaic (PV) applications. Through the cascade of sub-modules (SM), the converter has a high step-up ratio to connect MVdc bus. However, it has many ports which increase the risk of short-circuit faults. Therefore, this article proposes a fault ride-through (FRT) topology for multiport converter. When low-voltage ports are short-circuited, they can be isolated by blocking the switches of their own. The FRT topology can support the output voltage of faulty SMs to avoid the disconnection from MVdc bus. Other healthy ports can still generate power to MVdc bus. When the medium-voltage port is short-circuited, the FRT topology can quickly clear the fault current to prevent devices from being damaged. Due to the zero voltage switching, the proposed topology has higher efficiency. For medium-voltage fault, the FRT topology has faster fault clearing speed because more capacitors are reused. Finally, the proposed topology is verified by simulation and experiment.

26 January 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
XDXiaoguang Diao
Xiaoguang Diao
FLFei Liu
Fei Liu
YSYuan Song
Yuan Song
MXMengyue Xu
Mengyue Xu
YZYizhan Zhuang
Yizhan Zhuang
XZXiaoming Zha
Xiaoming Zha
Z/T/Γ-source circuit breakers used in flexible DC distribution systems have been rapidly developed due to their advantages of high speed and low cost. However, the precise model of the circuit breaker is generally a high-order circuit, which is difficult to solve. The lack of simplified topology and parameter design considering system parameters (line inductance, line resistance and load capacitance) restricts their applications in practical engineering. Therefore, based on the equivalent mathematical model, a simplified topology that can represent Z/T/Γ-source circuit breakers is proposed and their working principles are revealed in this paper. Considering system parameters, the parameters of Z/T/Γ-source circuit breakers are designed to take care of short circuit fault and step changes in load. Finally, simulation and experiment show that parameters designed by the proposed method can ensure the reliable operation for Z/T/Γ-source circuit breakers.