Xiaoguang Diao

Xiaoguang Diao

Auto-generated profile, based on publicly available information

Xiaoguang Diao

Hubei Key Laboratory of Power Equipment and System Security for Integrated Energy, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YZYizhan Zhuang
Yizhan Zhuang
FLFei Liu
Fei Liu
YHYanhui Huang
Yanhui Huang
SWShiwen Wang
Shiwen Wang
SPShangzhi Pan
Shangzhi Pan
XDXiaoguang Diao
Xiaoguang Diao
In the traditional dc distribution networks with both a low-voltage dc (LVdc) and a medium-voltage dc (MVdc) bus, dc units, such as photovoltaics solar, storage devices, and dc loads, are connected to the LVdc bus through LVdc converters, such as dc/dc boost converters and bidirectional buck–boost dc/dc converters. In this approach, no galvanic isolation is provided and two power conversion stages are needed between the dc units and the MVdc grid, hence leading to a high number of converters and higher costs. To address these shortcomings, this article proposes a novel multiport dc solid-state transformer (MDCSST) to interface these dc units directly to the MVdc bus. Multiple modules are connected in series on the medium-voltage side to the MVdc bus, whereas dc units are independently connected on the low-voltage side of the MDCSST. Compared with a traditional dc distribution network, the proposed scheme connects dc units to the MVdc bus without an extra converter or an LVdc bus, therefore, saving cost and reducing the number of converters. In addition, dc units are galvanically isolated by high-frequency transformers. The main challenge of the MDCSST is to resolve the voltage-imbalance problem on the MVdc side, which is caused by the dc units’ power differences. An LC branch is used to balance the voltages among the modules and to transfer their differential powers. Simulations and experiments were carried out to validate the proposed approach and verify the theoretical analysis.

26 April 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
YHYanhui Huang
Yanhui Huang
FLFei Liu
Fei Liu
YZYizhan Zhuang
Yizhan Zhuang
XDXiaoguang Diao
Xiaoguang Diao
ZLZhouyang Liu
Zhouyang Liu
XZXiaoming Zha
Xiaoming Zha
The input-independent and output-series (IIOS) structure is often used in the high step-up ratio converters required for medium-voltage dc (MVdc) grid interface of photovoltaic (PV) systems, which achieves high voltage gain and ensures high efficiency. However, due to the characteristics of IIOS structure, when some PV arrays are shadowed or malfunction, the generated power of these modules will be mismatched. Mismatched power will result in output capacitor voltages deviating from the rated value, which is not conducive to the standardized multimodule design. Besides, voltages of some PV arrays will deviate from their maximum power point (MPP) value, leading to a decrease in the total generated power. In order to balance the module output voltages of the IIOS structure, this article proposes bidirectional buck-boost and series LC- based power balancing units (LC-PBUs) for PV dc collection systems. Compared with a traditional solution, nearly half of the switches are saved and half of the inductors are displaced by small inductors. Power balance can be achieved through the LC -PBUs by controlling the duty ratio and the phase of the pulse-width modulation (PWM) signal. Simulations and experiments are carried out to verify the effectiveness of LC -PBU under power sags.

14 June 2022 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
XDXiaoguang Diao
Xiaoguang Diao
FLFei Liu
Fei Liu
YZYizhan Zhuang
Yizhan Zhuang
YHYanhui Huang
Yanhui Huang
SPShangzhi Pan
Shangzhi Pan
XZXiaoming Zha
Xiaoming Zha
The input independent output series dc/dc converter has one stage of power conversion, which has low cost and high efficiency. However, shadow occlusion, dust coverage, and manufacturing differences will cause power mismatch of the photovoltaic panels, which in turn causes an unbalanced output voltage. To avoid device damage and power degradation caused by unbalanced voltage, a novel topology based on multiwinding transformer is proposed. By multiplexing the switches of each sub-module (SM), this topology can transmit the mismatched power among all the SMs and balance the output voltages. In the traditional method, the mismatched power can only be transferred between adjacent SMs. When the power mismatched SMs are far away, differential power will go through many SMs to reach the target one, causing unnecessary power losses. In the proposed topology, mismatched power can be directly transferred to the target SM; therefore, it has higher efficiency. Moreover, all the switches have zero voltage switching, which further improves the efficiency. One-third of the switches in the proposed topology have lower current stress than the traditional topology. The hardware cost can be reduced. Finally, the proposed topology is verified by simulation and experiment of 1 kW.

15 April 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YHYanhui Huang
Yanhui Huang
FLFei Liu
Fei Liu
YZYizhan Zhuang
Yizhan Zhuang
XDXiaoguang Diao
Xiaoguang Diao
YLYu Lei
Yu Lei
HZHongxi Zhu
Hongxi Zhu
Using retired power batteries in battery energy storage systems (BESSs) is beneficial for environmental protection and cost reduction. Modular multilevel converter (MMC) is the most promising structure in power conversion systems integrated with retired power batteries. However, in MMC-based BESS, intersubmodule active power disparity is inevitable. It will lead to an increase in fundamental circulation and capacitor voltage ripple, limiting the usable capacity of the battery. This article proposes a bidirectional three-port converter (BTPC) configuration suitable for MMC-based BESS. It ensures that retired batteries can set up charging/discharging strategies according to their states-of-health and state-of-charge, while maintaining power balance at each port of the MMC. This configuration facilitates the integration of a large number of retired batteries into the grid via the MMC converter. In light of the BTPC configuration, the battery charge/discharge control strategy and power balance strategy are proposed. Simulation and experimental results are obtained on a single-phase system, verifying the effectiveness of the proposed converter and the corresponding control strategy.

7 October 2020 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
XDXiaoguang Diao
Xiaoguang Diao
FLFei Liu
Fei Liu
YSYuan Song
Yuan Song
MXMengyue Xu
Mengyue Xu
YZYizhan Zhuang
Yizhan Zhuang
XZXiaoming Zha
Xiaoming Zha
Flexible DC distribution networks have been widely developed because of their advantages of high efficiency, low cost, and easy access to renewable energy. However, as distribution networks have more ends than the two-terminal transmission line, it is more challenging to protect them and locate their faults. Therefore, this paper proposes a modified T-source circuit breaker to protect against DC faults. Based on the proposed circuit breaker, an integral fault location method using double-terminal asynchronous data is proposed. The accuracy of the algorithm is not affected by the fault resistance. There are no differential terms in the algorithm, which greatly reduces the sensitivity to noise. The integral algorithm can remain steady when the voltage and current are zero in oscillation and attenuation periods. This constitutes the main contribution of this paper. Finally, it is verified by simulation and experiment that the proposed circuit breaker can isolate the power source within a short time in the typical DC distribution network. Under a noise of 30 dB for simulation, the location error of the proposed algorithm is <0.4% when the fault resistance is 0.5 Ω–500 Ω.

4 January 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
YLYu Lei
Yu Lei
YZYizhan Zhuang
Yizhan Zhuang
FLFei Liu
Fei Liu
XDXiaoguang Diao
Xiaoguang Diao
YHYanhui Huang
Yanhui Huang
To construct the bipolar dc microgrid and maintain the poles voltage balanced, usually a dedicated voltage balancer (VB) is needed. In this article, a general four-port converter with a series LC voltage balancer (LCVB) is proposed to replace the VB. The proposed converter is composed of two partial power processing dual-active bridges (PDABs) and a series LC branch. The LC branch is added between the outputs of two PDABs, which are combined with half-bridge circuits to form LCVB. Two PDAB inputs can realize independent bidirectional power flow according to the requirements of the connected equipment. At the same time, LCVB can also balance the bipolar voltage levels. In addition, compared with the traditional two-module double active bridge converter, the proposed converter has no additional active switching device. Partial power processing structure improves the converter efficiency. Lastly, all the switches of PDAB turn on with zero-voltage switching. Simulations and experiments are carried out to verify the validity of the converter.