Fei Liu

Fei Liu

Auto-generated profile, based on publicly available information

Fei Liu

School of Electrical Engineering and Automation, Wuhan University, Wuhan, China

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2019 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JJJianbo Jiang
Jianbo Jiang
FLFei Liu
Fei Liu
SPShangzhi Pan
Shangzhi Pan
XZXiaoming Zha
Xiaoming Zha
WLWenjun Liu
Wenjun Liu
LHLidong Hao
Lidong Hao
Large disturbance scenarios such as pulse power load operation and load switching are commonly seen in the operation of DC microgrids. The mixed potential theory-based large-signal stability (LSS) analysis is a simple and practical method for investigating the LSS of DC microgrids. However, this method is characterized by conservatism, and produces conservative stability criterion results. When they are applied to the parameter designs of DC microgrids, they create excessive control parameter redundancies; when used for running status estimations, they may cause the system to be misjudged as unstable, and trigger unnecessary protective actions when the system runs into the conservative region. This paper presents a comprehensive analysis of the conservatism, revealing its main causes to be the idealization of the load converter's response characteristics, and the lack of refined models. It then proposes a novel, improved analysis method for transient response characteristics of the load converter. Experimental and simulation results using the improved method have validated it by showing that the conservatism of the traditional method had been eliminated, and the stability criterion obtained was more accurate.

28 April 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
ZTZhen Tian
Zhen Tian
YTYingjie Tang
Yingjie Tang
XZXiaoming Zha
Xiaoming Zha
JSJianjun Sun
Jianjun Sun
MHmeng huang
meng huang
FLFei Liu
Fei Liu
As the crucial interface of renewable energy integration, the stable operation of power converters under grid faults and external disturbances has become much more important. However, synchronization instability of grid-tied inverters has been found caused by the phase-locked loop (PLL) under some critical operating conditions, such as the grid voltage sag, current surge, and transmission line faults. Due to the strong nonlinearity, transient stability analysis of inverters with PLL becomes much more complicated under large-signal perturbations and weak grid conditions. In this article, the large-signal synchronization stability of grid-tied inverters is investigated from the energy perspective. Based on the structural resemblance between the PLL and synchronous generator, the energy function is constructed to establish a port-Hamiltonian model for the grid-tied inverter. For the nonlinear inverter system, an explicit Hamilton-based stability criterion is developed for grid-tied converters according to the concept of dissipativity and LaSalle’s theorem. Moreover, the analytical stability boundary is acquired based on the proposed stability criterion and attraction region estimation, covering both controller parameters and grid parameters. To verify the effectiveness of the proposed analysis approach, extensive simulation and experimental results are presented. Compared with the conventional large-signal methods, the proposed Hamilton-based approach has explicit physical meaning and high accuracy.

2 December 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YZYizhan Zhuang
Yizhan Zhuang
FLFei Liu
Fei Liu
YHYanhui Huang
Yanhui Huang
ZLZhouyang Liu
Zhouyang Liu
SPShangzhi Gae Pan
Shangzhi Gae Pan
JJJianbo Jiang
Jianbo Jiang
An input-independent and output-series (IIOS) modular DC-DC converter with multiple input ports and high voltage conversion ratio can apply well to medium-voltage DC (MVDC) interface of distributed photovoltaics (PV). However, PV power mismatch will result in output voltage imbalance of the submodules (SMs), which is contrary to the standardized multi-module design. In this paper, a multiport modular DC-DC converter with low-loss series LC power balancing unit (PBU) is proposed to address this problem. An isolated DC-DC converter is employed as the SM, which consists of full-bridge (FB) circuit on the PV side and half-bridge (HB) circuit on the grid side. Independent maximum power point tracking (MPPT) can be realized by controlling the phase shift between the FB and the HB, while voltage balancing (or power balancing) of SMs can be achieved by regulating the phase shift between adjacent HBs. Only one inductor and one capacitor are used in the PBU and all the switches of SM turn on with zero-voltage switching (ZVS), which contributes to the low-cost and low-loss characteristic of the converter. Simulations and experiments are carried out to verify the validity of the theory.

7 December 2018 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
WLWenjun Liu
Wenjun Liu
FLFei Liu
Fei Liu
YZYizhan Zhuang
Yizhan Zhuang
XZXiaoming Zha
Xiaoming Zha
CCChao Chen
Chao Chen
TYTianyi Yu
Tianyi Yu
Although hybrid circuit breaker (HCB) uses a combination of mechanical switch and insulated-gate bipolar transistors (IGBTs) to accommodate HVDC application, it still has a large number of series-connected IGBTs in its main breaker. Besides, in multiterminal HVDC system, three or more HCBs appear in cluster at one node, which worsens the HCBs' disadvantage in volume. To simplify the breaker cluster's topology structure and control system as well as increase the compactness, a multiport circuit breaker (MPCB) is proposed in this paper with its control procedure presented. By assembling the HCBs at one node, it can not only cut down the component count for fault interruption remarkably but also reduces the number of control signals. Apart from this, due to a more compact structure, the proposed circuit breaker avoided the use of a dc bus and, hence, dc bus fault which will result in disconnecting the node completely from the system. Hence, regardless of faults and their fault locations, it is always able to connect the remaining healthy ports together. Finally, the effectiveness of the proposed MPCB in different fault scenarios is verified by RTlab.

22 June 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YZYizhan Zhuang
Yizhan Zhuang
FLFei Liu
Fei Liu
XZXiangjing Zhang
Xiangjing Zhang
YHYanhui Huang
Yanhui Huang
XZXiaoming Zha
Xiaoming Zha
ZLZhouyang Liu
Zhouyang Liu
A multiport DC/DC converter with cascaded submodules (SMs) can be employed in photovoltaic (PV) power generation system for its high step-up ratio. Consisting of multiple low-voltage (LV) input ports and one high-voltage (HV) output port, the multiport converter is more likely to suffer short-circuit faults than a two-port converter. To ensure reliable operation of the converter, its short-circuit fault-tolerant capability should be necessarily considered. In this paper, a short-circuit fault-tolerant topology for multiport cascaded DC/DC converter in PV power generation system is proposed to satisfy the requirements of fault tolerance ability. When one or more short-circuit faults occur at LV ports, the proposed topology guarantees the normal operation of other fault-free SMs. When a short-circuit fault occurs at the HV port, the short-circuit fault current can be interrupted rapidly by the fault-tolerant topology, which protects the converter from a large current surge. The fault-tolerant ability of the proposed topology is verified by both simulation and experimental results.

18 August 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
YZYizhan Zhuang
Yizhan Zhuang
FLFei Liu
Fei Liu
YHYanhui Huang
Yanhui Huang
SWShiwen Wang
Shiwen Wang
SPShangzhi Pan
Shangzhi Pan
XDXiaoguang Diao
Xiaoguang Diao
In the traditional dc distribution networks with both a low-voltage dc (LVdc) and a medium-voltage dc (MVdc) bus, dc units, such as photovoltaics solar, storage devices, and dc loads, are connected to the LVdc bus through LVdc converters, such as dc/dc boost converters and bidirectional buck–boost dc/dc converters. In this approach, no galvanic isolation is provided and two power conversion stages are needed between the dc units and the MVdc grid, hence leading to a high number of converters and higher costs. To address these shortcomings, this article proposes a novel multiport dc solid-state transformer (MDCSST) to interface these dc units directly to the MVdc bus. Multiple modules are connected in series on the medium-voltage side to the MVdc bus, whereas dc units are independently connected on the low-voltage side of the MDCSST. Compared with a traditional dc distribution network, the proposed scheme connects dc units to the MVdc bus without an extra converter or an LVdc bus, therefore, saving cost and reducing the number of converters. In addition, dc units are galvanically isolated by high-frequency transformers. The main challenge of the MDCSST is to resolve the voltage-imbalance problem on the MVdc side, which is caused by the dc units’ power differences. An LC branch is used to balance the voltages among the modules and to transfer their differential powers. Simulations and experiments were carried out to validate the proposed approach and verify the theoretical analysis.