Mianjun Xiao

Mianjun Xiao

Auto-generated profile, based on publicly available information

Mianjun Xiao

State Key Laboratory of Clean and Efficient Turbomachinery Power Equipment, Department of Mechanical Engineering, Tsinghua University, Beijing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2023 in IEEE Access
Verified
Journal Article
Open access
LSLiangjun Shao
Liangjun Shao
PSPeng Song
Peng Song
YYYufan Yan
Yufan Yan
XZXintao Zhang
Xintao Zhang
MXMianjun Xiao
Mianjun Xiao
TQTiming Qu
Timing Qu
REBa 2 Cu 3 O 7-x (REBCO) coated conductor has emerged as a promising material for the development of ultra-high-field (UHF) magnets. However, the presence of screening-current induced strain within this tape-shaped conductor exerts a huge impact on the operational stability of REBCO coils. We focused on the design of an all-superconducting 36 T / 40 mm UHF magnet, which included a 16 T insert magnet consisting of two nested REBCO coils. In this study, the screening-current induced strain in the 16 T magnet was numerically studied using the coupled electromagnetic-mechanical model, which considered the tilting angle of REBCO tapes and the strain dependency of the critical current. We calculated the screening-current induced strain of each pancake individually and compared these results with those calculated by the sequential model. According to the coupled model, the maximum hoop strain was 0.52 %, relatively lower than that calculated by sequential model. The most dangerous pancake was estimated to be the outermost pancake of each coils. Additionally, we varied the critical current value of the REBCO tapes and studied the relationship between the critical current value and screening-current induced strain. This work provides a feasible way to calculate the screening-current effect in large-scale HTS magnets.

1 June 2023 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
ZYZhirong Yang
Zhirong Yang
PSPeng Song
Peng Song
YLYiran Li
Yiran Li
LSLiangjun Shao
Liangjun Shao
MXMianjun Xiao
Mianjun Xiao
TQTiming Qu
Timing Qu
Epoxy impregnated superconducting coils have better structural integrity and thermal stability. However, for REBa2Cu3O7−δ (REBCO, RE=Rare earth) coils, the mismatch of thermal expansion coefficients between epoxy and REBCO tapes is a serious problem. In this work, the temperature distribution, stress evolution during the cooling process, critical current distribution, and delamination sites inside REBCO coils impregnated using Stycast 2850FT have been studied. We measured the temperature distribution and the hoop strain in the penultimate turn of impregnated coils during the cooling process and analyzed the thermal stress evolution. No damage was observed for coils with the ratio between outer and inner diameter Ro/Ri2.37, where the coils even exhibited a two-stage delamination. The delamination mechanism of REBCO coils was proposed from three aspects: the mechanical analysis, the critical current degradation, and the microscopic analysis. In this work, we found that the actual delamination behavior may appear earlier than the steady-state temperature, and temperature distribution will push the radial stress peak toward the inner radius of the coil, making the inner turn more susceptible to delamination. Multiple delamination locations were accurately predicted and confirmed. The measured compressive hoop strain first increased from −4212 με to −4684 με with the increase in Ro/Ri and then decreased to −3835 με obviously due to delamination. This work reveals in detail the delamination mechanism in impregnated REBCO coils, which is of great significance for the development of damage-free coils.

1 December 2025 in Superconductor Science and Technology
Verified
Journal Article
Closed access
YLYulong Liu
Yulong Liu
PSPeng Song
Peng Song
MXMianjun Xiao
Mianjun Xiao
LSLiangjun Shao
Liangjun Shao
ZXZiyang Xu
Ziyang Xu
TQTiming Qu
Timing Qu
No-insulation (NI) coils are known for their high thermal stability and self-protection features due to turn-to-turn contacts. Parallel co-winding is a promising method to reduce the charging delay of NI coils while maintaining thermal stability, demonstrating significant potential for applications in fusion and other large-scale or high-field magnets. The non-uniform current distribution among parallel superconducting tapes in parallel co-wound NI coils may lead to thermal and mechanical stability issues. In this work, we conducted current measurement experiments on small parallel co-wound NI rare-earth barium–copper-oxide coils to investigate the non-uniform current distribution and its influencing factors. The parallel tapes in the input and output sections of the test coils were separated and a series of Rogowski coils was used to measure the current in each tape during ramping charging process. We employed a field-circuit coupled model based on the T–A formulation to calculate the current distribution in co-wound coils. Both the measured and calculated results indicated that the current distribution during ramping was highly non-uniform, with some tapes carrying reverse currents. We calculated the current distribution in co-wound coils with different insulation methods and analyzed the influencing factors of the reverse current. The effects of terminal resistance on current distribution were investigated, and the magnetization and coupling losses during ramping were analyzed. This work could contribute to a deeper understanding of current distribution behavior in co-wound NI coils and provide insights for their application in large-scale or high-field magnets.

8 December 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
LFLuyang Fan
Luyang Fan
PSPeng Song
Peng Song
MXMianjun Xiao
Mianjun Xiao
LSLiangjun Shao
Liangjun Shao
Feng FengFeng Feng
Feng Feng
TQTiming Qu
Timing Qu
High-Temperature Superconducting (HTS) dipole magnets are of great importance for compact gantry systems of future particle beam radiation therapies. This study presents the design and fabrication of a prototype HTS dipole magnet, consisting of two Canted-Cosine-Theta (CCT) coils wound with 70 meters of 6-mm diameter Conductor on Round Core (CORC) type cable. The inner and outer coils, with 40 and 41 turns respectively, are concentrically installed with a radial gap of 10 mm. The main structure is made of anodized aluminum alloy 6061, and the connection between the two coils is achieved through a praying-hands type cable joint. Fastening and hoisting structures are added to form a compact magnetic unit. This magnet prototype aims to achieve a target dipole field of 0.5 T at 4.2 K in the 164-mm diameter aperture with an operation current of 3.25 kA. It was successfully charged to 300 A during the 77 K test, reaching the design target, thus facilitating initial validation of the feasibility of the design methods and manufacturing processes.

18 February 2025 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
ZXZiyang Xu
Ziyang Xu
PSPeng Song
Peng Song
MGMingzhi Guan
Mingzhi Guan
YLYulong Liu
Yulong Liu
CXCanjie Xin
Canjie Xin
TQTiming Qu
Timing Qu
A new testing facility employing a 15 T transverse field to evaluate the full-service-field characteristics of superconducting materials is now under development in China. A primary objective involves producing a large bore 15 T dipole magnet to serve as the source of the transverse magnetic field load. In this study, we designed and constructed a compact high-temperature superconducting (HTS) dipole magnet insert, comprising six block-type double pancake (DP) coils wound with REBCO tapes. The insert features a user bore of 34 mm and an outer diameter of 110 mm, expected to generate a 5 T field at 4.2 K with an operating current of 278 A, within a 10 T low-temperature superconducting (LTS) background dipole magnet. According to numerical simulations, the sextupole coefficient $b_{\mathrm{3}}$ is less than $5\times 10^{-3}$ and the operating point $I_{\text{op}}/I_{\mathrm{c}}$ is below 0.6 considering the screening current. Circumferential reinforcement structures were externally integrated to the REBCO coil assembly to mitigate electromagnetic stress under high background fields. The magnet was successfully charged to 43 A, achieving a central field of 0.71 T at 77 K, validating the winding process and joint techniques. The no-insulation characteristics were analyzed based on the test data. This work is important for advancing practical high-field HTS dipole magnets with high stability and field uniformity.

3 January 2024 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YLYulong Liu
Yulong Liu
PSPeng Song
Peng Song
MXMianjun Xiao
Mianjun Xiao
LSLiangjun Shao
Liangjun Shao
MGMingzhi Guan
Mingzhi Guan
TQTiming Qu
Timing Qu
REBa ${_{2}}$ Cu ${_{3}}$ O $_{7-\delta }$ (REBCO) coated conductor is a promising material for future accelerator magnets. The flat and wide geometry of REBCO tapes can result in the screening current induced magnetic field (SCF), leading to a significant influence on magnetic field quality in REBCO magnets. Considering the influence of the SCF on field quality, we designed a block-type dipole magnet consisting of six no-insulated double-pancake coils wound with REBCO tapes, capable of theoretically achieving 3 T at 4.2 K. We optimized the position of each coil and applied passive and active shimming structures to improve the field quality during the magnet design. According to numerical simulations, the absolute value of sextupole coefficient ${b_{3}}$ could be increased from 0.0681 units to 33.2 units by the SCF. To address this issue, passive and active shimming structures were specifically designed for the ${B_{3}}$ field. As a result, the absolute value of ${b_{3}}$ in the 20 mm aperture could be reduced from the original 33.2 units to 0.881 units and 0.322 units, respectively. The magnet was constructed and tested at 77 K. The central magnetic field reached 0.59 T as expected when the magnet was charged to 38.9 A. The no-insulation characteristics of the magnet based on the test results were discussed.