14 May 2024 in Superconductor Science and Technology
The screening-current effect is an inhomogeneous distribution of current density inside the REBCO conductors. The additional strain induced by the screening current, known as screening-current induced strain (SCS), is considered to affect the structural integrity of REBCO windings, especially when operating high-field REBCO insert magnets. In this work, we wound and tested a series of 50-turn REBCO coils inside a 10 T LTS external to investigate the influencing mechanism of multiple electromagnetic factors on SCS. We varied the critical current in different coils by different heat treatment procedures. Each coil was tested individually, experiencing a external field cycle and multiple operation current cycles at constant external fields. The extreme scenario for each coil was being energized to 400 A while the external field was 10 T. We adapted the discrete-coupled model to estimate the hoop strain distribution, monitored the experimental results by multiple strain gauges at the outermost turn. Test coil with a lower critical current endured a lower maximum hoop strain. When we were energizing the test coils, hoop strain increased at the edge of REBCO tapes while remaining nearly constant in the middle region. Additionally, the maximum hoop strain at the outermost turn decreased after each excitation cycle. This work could be an experimental reference for optimizing the electromagnetic design and the excitation scheme during the development of high-field REBCO magnets.
1 December 2025 in Superconductor Science and Technology
No-insulation (NI) coils are known for their high thermal stability and self-protection features due to turn-to-turn contacts. Parallel co-winding is a promising method to reduce the charging delay of NI coils while maintaining thermal stability, demonstrating significant potential for applications in fusion and other large-scale or high-field magnets. The non-uniform current distribution among parallel superconducting tapes in parallel co-wound NI coils may lead to thermal and mechanical stability issues. In this work, we conducted current measurement experiments on small parallel co-wound NI rare-earth barium–copper-oxide coils to investigate the non-uniform current distribution and its influencing factors. The parallel tapes in the input and output sections of the test coils were separated and a series of Rogowski coils was used to measure the current in each tape during ramping charging process. We employed a field-circuit coupled model based on the T–A formulation to calculate the current distribution in co-wound coils. Both the measured and calculated results indicated that the current distribution during ramping was highly non-uniform, with some tapes carrying reverse currents. We calculated the current distribution in co-wound coils with different insulation methods and analyzed the influencing factors of the reverse current. The effects of terminal resistance on current distribution were investigated, and the magnetization and coupling losses during ramping were analyzed. This work could contribute to a deeper understanding of current distribution behavior in co-wound NI coils and provide insights for their application in large-scale or high-field magnets.
18 February 2025 in IEEE Transactions on Applied Superconductivity
A new testing facility employing a 15 T transverse field to evaluate the full-service-field characteristics of superconducting materials is now under development in China. A primary objective involves producing a large bore 15 T dipole magnet to serve as the source of the transverse magnetic field load. In this study, we designed and constructed a compact high-temperature superconducting (HTS) dipole magnet insert, comprising six block-type double pancake (DP) coils wound with REBCO tapes. The insert features a user bore of 34 mm and an outer diameter of 110 mm, expected to generate a 5 T field at 4.2 K with an operating current of 278 A, within a 10 T low-temperature superconducting (LTS) background dipole magnet. According to numerical simulations, the sextupole coefficient $b_{\mathrm{3}}$ is less than $5\times 10^{-3}$ and the operating point $I_{\text{op}}/I_{\mathrm{c}}$ is below 0.6 considering the screening current. Circumferential reinforcement structures were externally integrated to the REBCO coil assembly to mitigate electromagnetic stress under high background fields. The magnet was successfully charged to 43 A, achieving a central field of 0.71 T at 77 K, validating the winding process and joint techniques. The no-insulation characteristics were analyzed based on the test data. This work is important for advancing practical high-field HTS dipole magnets with high stability and field uniformity.
12 February 2025 in IEEE Transactions on Applied Superconductivity
During operation, the central solenoid (CS) magnet in the Tokamak undergoes rapid charging-discharging cycles, resulting in significant AC losses. In this study, a loss and thermal analysis of a high temperature superconducting (HTS) CS magnet during operation was conducted. The magnet consists of 6 sub-magnets, each with 19 double pancakes (DPs), which are cooled to 20 K by helium gas in the cooling plates. The T-A model coupled with the equivalent circuit model was employed to calculate the hysteresis and coupling losses in the REBCO stacks. Additionally, eddy current losses in the copper layer of the REBCO tapes and the magnet structure were evaluated through the analytical formula and Finite Element Method (FEM) model under the uniform current assumption, respectively. A thermal model incorporating helium gas flow was developed to predict the temperature rise within the CS magnet. AC losses calculated during operation were integrated into the thermal model as heat sources, enabling quantitative analysis of the magnet's temperature evolution.
22 October 2025 in IEEE Transactions on Applied Superconductivity
High-temperature superconducting (HTS) dipole magnet inserts with higher magnetic fields can improve the performance of future dipole magnets. In support of the 15 T Full-Service-Field Testing Facility for characterizing superconducting materials under extreme transverse fields, we developed a compact HTS insert to generate a 2.5 T field in a 12.5 T LTS background magnet. The magnet comprises six block-type no-insulation double pancakes (DP) wound with REBCO tapes, featuring a 34 mm user bore. Each DP coil includes hard bending at both ends with a bending radius of 1 m. The strong forces induced by high field significantly affect the structural stability of the magnets, presenting a key technical challenge for HTS inserts. To suppress the electromagnetic stress, edge-pressing structures were installed on both sides of the coils, while magnet shells and reinforcement rings were mounted on the outer side. During the self-field test at 4.2 K, the magnet was charged to 301 A, achieving a central field of 5.02 T with measured structural strain below 0.13% . Over three charging cycles, small voltage spikes were observed during current ramping, most of which disappeared in subsequent cycles. No damage was observed afterward. This work provides valuable validation of the design methodology and fabrication techniques for block-type HTS dipole magnets with hard bending.
10 March 2026 in IEEE Transactions on Applied Superconductivity
The electromagnetic coupling effect induced by mutual inductance between two independent magnets during quench is non-negligible. This study focuses on the preliminary design of a hybrid dipole magnet for a 15 T Full-Service Field Testing Facility, which consists of a 6 T low-temperature superconducting (LTS) magnet and a 5 T no-insulation (NI) high-temperature superconducting (HTS) insert, featuring a 34-mm user bore. An equivalent circuit model was developed to analyze the electromagnetic response of the HTS insert during LTS magnet charging. The analysis shows that when the LTS magnet dumps, mutual inductance induces large current and voltage peaks in the HTS insert, the magnitude of which depends on the operating current of the HTS and the dump current of the LTS. Finally, low-field dump tests were performed on the hybrid magnet at 4.2 K. A voltage peak of 0.45 V was detected in the HTS insert when the LTS magnet dumped at 370 A, in agreement with the analysis. The test results verify the model's capability to capture such dynamic electromagnetic behaviors and provide a foundation for understanding the interaction mechanism in nested magnets during quench.