Tian Zhao

Tian Zhao

Auto-generated profile, based on publicly available information

Tian Zhao

Beihang University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2022 in Optics Express
Verified
Journal Article
Closed access
XFXiujie Fang
Xiujie Fang
KWKai Wei
Kai Wei
YZYueyang Zhai
Yueyang Zhai
TZTian Zhao
Tian Zhao
XCXu Chen
Xu Chen
ZXZhisong Xiao
Zhisong Xiao
The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.

18 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XHXing Heng
Xing Heng
Kai WeiKai Wei
Kai Wei
TZTian Zhao
Tian Zhao
ZXZitong Xu
Zitong Xu
QCQian Cao
Qian Cao
WQWei Quan
Wei Quan
Optical rotation detection system (ORDS) utilizing quantum nondemolition measurement methods is widely applied in the field of quantum metrology and quantum information. However, the sensitivity of ORDS is limited by the uncertainty from optical-couple noise during the measurement of the atomic spin ensemble. In this study, we specifically analyze the mechanism of optical-couple noise caused by the fluctuations of probe light’s polarization in the modulated ORDS with a new model established to describe atomic spin precession in this particular condition. It is discovered that transverse electron-spin polarization errors are generated by the residual probe photon spin polarization in the ORDS, which results in extra coupling magnetic noise. In order to suppress this noise, a novel in-situ method is proposed that the resultant electron-spin errors are reduced by a specifically designed closed-loop system. The results are verified through the ORDS in a co-magnetometer. After zeroing the extra probe photon spin polarization, an angular sensitivity better than 1×10 -8 rad/Hz 1/2 is achieved for frequencies higher than 5 Hz, demonstrating a probe background noise of 0.26 fT/Hz 1/2 @14.5 Hz, approaching electronic noise and photon shot noise. With closed-loop control, the optical rotation bias instability is promoted by 4.2 times (from 107.9 to 25.7 μrad/h), and the angular noise of the ORDS is reduced by 2.4 times at 1-100 Hz. The measurement uncertainty of the realized ORDS nears the standard quantum limit, paving the road for long-term ultrasensitive measurements for new physics explorations.

25 October 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZXZitong Xu
Zitong Xu
Kai WeiKai Wei
Kai Wei
TZTian Zhao
Tian Zhao
QCQian Cao
Qian Cao
YLYing Liu
Ying Liu
YZYueyang Zhai
Yueyang Zhai
As the measurement of multiple parameters in a spin-exchange relaxation-free (SERF) comagnetometer requires a long time and complex experimentation, we present a novel dynamic frequency response-based method for the accurate and rapid measurement of key parameters in a SERF comagnetometer. By testing the dynamic frequency response to a transverse oscillating magnetic field, we can obtain multiple parameters simultaneously and quickly without interrupting the operation of the comagnetometer. This method simultaneously measures the nuclear longitudinal relaxation rate and alkali metal number density within minutes, with uncertainties of less than 20.8% and 14.0%, respectively. The main error sources in the nuclear longitudinal relaxation rate and alkali metal number density are the spin-exchange rate constant and spin-exchange enhancement factor, respectively. In addition, the polarization of alkali metal and noble gas atoms can be obtained during the experimental process, and the fast measurement of these parameters is beneficial for applications requiring simultaneous and in situ measurement of spin ensemble performance.

15 July 2022 in Optics Express
Verified
Journal Article
Closed access
TZTian Zhao
Tian Zhao
YZYueyang Zhai
Yueyang Zhai
CLChang Liu
Chang Liu
HXHongtai Xie
Hongtai Xie
QCQian Cao
Qian Cao
XFXiujie Fang
Xiujie Fang
We investigate the effects of the density ratio of K-Rb hybrid cells on the alkali metal-noble gas comagnetometers. Bloch equations simplified with the density ratio and average-pumping-rate model are presented for numerical simulation, which simplifies equations of complete hybrid spin ensemble and problem of polarization gradient. The spin polarizations of electron and nucleon, total electronic relaxation rates, and the spin-exchange efficiencies are measured with cells of different density ratios. The results are in good agreement with our equivalent model. Based on our theoretical analysis, the K-Rb-21Ne comagnetometer achieves maximum output signal by optimizing the combination of density ratio and optical power density. The density ratio is critical to the homogeneity of spin polarization and efficiency of hyperpolarization. The method in this work finds a way to optimize the sensitivity of comagnetometers, which is significant for angular-rotation sensors and new physics research.

21 January 2022 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
TZTian Zhao
Tian Zhao
YLYing Liu
Ying Liu
Kai WeiKai Wei
Kai Wei
HXHongtai Xie
Hongtai Xie
TMTangjie Mu
Tangjie Mu
YZYueyang Zhai
Yueyang Zhai
Ultra-sensitive comagnetometers, which are designed to detect nuclear- and electron-spin-dependent interaction, have important applications ranging from basic research to inertial navigation systems (INSs). Unfortunately, electric heating, which is typically used in comagnetometers, introduces noise and instability because of the unavoidable generation of a modulated magnetic field. In this study, we investigate and introduce a K-Rb-21Ne comagnetometer that uses laser heating for the first time, when operated in the spin exchange relaxation free regime. The performance of the comagnetometer, which is equipped with both laser heating and electric heating, is investigated, and the two heating modes are compared. The temperature characteristics of the comagnetometer are studied theoretically and experimentally. By optimizing the operating temperature and power density of the pump-light, an equivalent rotation sensitivity of 2.5 × 10 − 7 rad−1 s−1 Hz 1 / 2 @1 Hz is achieved in laser heating mode. The improvement of laser-heating technology could prove essential to reduce electron relaxation and increase the low-frequency sensitivity of comagnetometers. Our results indicate that laser heating can make comagnetometers more suitable for applications in basic research (fifth forces, dark matter, etc), INSs, and other accurate measurements of electronic and nuclear precession.

21 June 2022 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
CTChencheng Tang
Chencheng Tang
CLChang Liu
Chang Liu
CPCaio A G Prado
Caio A G Prado
TZTian Zhao
Tian Zhao
BHBangcheng Han
Bangcheng Han
YZYueyang Zhai
Yueyang Zhai
Alkali-metal-noble-gas comagnetometers operating in the spin exchange relaxation free regime have been widely used in frontier science research and navigation technology. Under normal circumstances, the comagnetometer operates at the compensation point so that any interfering external magnetic field is tracked and suppressed by the nuclear spin. This in turn can greatly diminish the comagnetometer’s sensitivity to the magnetic field; however, its sensitivity to rotations and to anomalous fields is still maintained. The compensation point is typically adjusted manually, which leads to low accuracy and compensation speed, in addition to only allowing short-term magnetic field stability. In order to account for these problems, we designed a three-axis magnetic field compensation system in real time based on LabVIEW, and employed it to a K−Rb − 21 Ne comagnetometer. Our study shows that by using a fuzzy proportional-integral (PI) controller, the compensation point can be tracked in real time and with higher precision when compared with manually adjusted methods, therefore improving the magnetic field stability and sensitivity of the comagnetometer.