An optical pumping scheme is proposed for reducing the gradient of electron spin polarization and suppressing light source noise in a spin-exchange relaxation-free magnetometer. This is achieved by modulating only the phase of a narrow-linewidth pump light field with external Gaussian noise. Compared to the absence of phase modulation, the uniformity of electron spin polarization was improved by over 40%, and the light-frequency noise suppression ratio of the magnetometer was enhanced by 4.3 times. Additionally, the response of the magnetometer was increased by 54%, resulting in a sensitivity of 0.34 fT/Hz1/2 at 30 Hz. The applicability of this scheme can extend to other optical pumping experiments involving large atom ensembles requiring uniform electron spin polarization distribution, which is beneficial for developing ultra-high sensitivity and high stability magnetometers essential for magneto-cardiography and magneto-encephalography research applications.
The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.
Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.
This study proposes a high-performance magnetic shielding structure composed of MnZn ferrite and mu-metal film. The use of the mu-metal film with a high magnetic permeability restrains the decrease in the magnetic shielding coefficient caused by the magnetic leakage between the gap of magnetic annuli. The 0.1–0.5 mm thickness of mu-metal film prevents the increase of magnetic noise of composite structure. The finite element simulation results show that the magnetic shielding coefficient and magnetic noise are almost unchanged with the increase in the gap width. Compared with conventional ferrite magnetic shields with multiple annuli structures under the gap width of 0.5 mm, the radial shielding coefficient increases by 13.2%, and the magnetic noise decreases by 21%. The axial shielding coefficient increases by 22.3 times. Experiments verify the simulation results of the shielding coefficient of the combined magnetic shield. The shielding coefficient of the combined magnetic shield is 16.5%. It is 91.3% higher than the conventional ferrite magnetic shield. The main difference is observed between the actual and simulated relative permeability of mu-metal films. The combined magnetic shielding proposed in this study is of great significance to further promote the performance of atomic sensors sensitive to magnetic field.
We investigate the effects of the density ratio of K-Rb hybrid cells on the alkali metal-noble gas comagnetometers. Bloch equations simplified with the density ratio and average-pumping-rate model are presented for numerical simulation, which simplifies equations of complete hybrid spin ensemble and problem of polarization gradient. The spin polarizations of electron and nucleon, total electronic relaxation rates, and the spin-exchange efficiencies are measured with cells of different density ratios. The results are in good agreement with our equivalent model. Based on our theoretical analysis, the K-Rb-21Ne comagnetometer achieves maximum output signal by optimizing the combination of density ratio and optical power density. The density ratio is critical to the homogeneity of spin polarization and efficiency of hyperpolarization. The method in this work finds a way to optimize the sensitivity of comagnetometers, which is significant for angular-rotation sensors and new physics research.