Ying Liu

Dr. Ying Liu

The School of Electronic and Information Engineering,Beihang University, Beijing, China
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2022 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JTJunjian Tang
Junjian Tang
YLYing Liu
Ying Liu
YWYaxiang Wang
Yaxiang Wang
BZBinquan Zhou
Binquan Zhou
BHBangcheng Han
Bangcheng Han
GLGang Liu
Gang Liu
We demonstrate the bandwidth enhancement of an all-optical spin-exchange relaxation-free (SERF) magnetometer based on amplitude-modulated (AM) light. Alkali metal atoms are modulated directly by the pump beam instead of the modulation field or radio frequency field. The first harmonic demodulation of an AM SERF magnetometer with a modulation intensity of 15 kHz results in a high bandwidth of over 11 kHz with a sensitivity of 20 fT/Hz1/2 at 30 Hz and 60 fT/Hz1/2 at 10 kHz. Meanwhile, the AM SERF magnetometer with DC demodulation presents the same sensitivity as a traditional DC SERF magnetometer (6 fT/Hz1/2 at 30 Hz). The presented technique for modulating the amplitude of the pump beam allows AM SERF magnetometers to enter the domain of high-bandwidth magnetometers and opens the door to many areas that are inaccessible to conventional magnetometers.

26 July 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
BZBinbin Zhao
Binbin Zhao
LLLin Li
Lin Li
YZYaohua Zhang
Yaohua Zhang
JTJunjian Tang
Junjian Tang
YLYing Liu
Ying Liu
YZYueyang Zhai
Yueyang Zhai
Alkali metal optically pumped magnetometers, with a particular emphasis on Spin-Exchange Relaxation-Free atomic magnetometers, has garnered considerable attention due to their remarkable sensitivity. In this comprehensive review, we present a succinct overview of the fundamental principle of the magnetometer and the various categories of its central sensitive unit, namely the cell. We then proceed to elaborate on the vital aspect of establishing an extremely feeble magnetic field environment that is crucial for its operation, inclusive of both active magnetic shielding and passive magnetic compensation methodologies. In furtherance, we conduct a thorough evaluation of the pros and cons of single-beam and dual-beam pump-probe scheme magnetometers, followed by a detailed investigation of their potential applications in the cardiology and brain magnetism fields. Finally, we conclude with an analysis of the hurdles and prospective development directions for alkali metal-based atomic magnetometers in the domains of magnetocardiography and magnetoencephalography, which hold the promise of substantial progress and widespread adoption in the biomedical area.

21 January 2022 in Optics Express
Verified
Journal Article
Closed access
XFXiujie Fang
Xiujie Fang
KWKai Wei
Kai Wei
YZYueyang Zhai
Yueyang Zhai
TZTian Zhao
Tian Zhao
XCXu Chen
Xu Chen
ZXZhisong Xiao
Zhisong Xiao
The magnetic field gradient within optical pumping magnetometers (OPMs) suppresses sensitivity improvement. We investigated the effects of the magnetic field gradient along the x-, y-, and z-axes on the limiting factors of magnetometers under extremely low magnetic field conditions. We modified the magnetic field gradient relaxation model such that it can be applied to atoms in the spin exchange relaxation free (SERF) regime. The gradient relaxation time and spin polarizations, combined with fast spin-exchange interaction, were determined simultaneously using the oscillating cosine magnetic field excitation and amplitude spectrum analysis method. During the experiments, we eliminated the errors caused by the temperature and pumping power, and considered different isotope spin exchange collisions in naturally abundant Rb during the data analysis to improve the fitting accuracy. The experimental results agreed well with those of theoretical calculations and confirmed the accuracy of the improved model. The contribution of the transverse magnetic field gradient to the relaxation of the magnetic field gradient cannot be ignored in the case of small static magnetic fields. Our study provides a theoretical and experimental basis for eliminating magnetic gradient relaxation in atomic sensors in the SERF region.

6 December 2020 in Materials
Verified
Journal Article
Open access
PDF file
YZYueyang Zhai
Yueyang Zhai
LCLi Cao
Li Cao
YLYing Liu
Ying Liu
XTXiaodi Tan
Xiaodi Tan
Polarization holography has the unique capacity to record and retrieve the amplitude, phase, and polarization of light simultaneously in a polarization-sensitive recording material and has attracted widespread attention. Polarization holography is a noteworthy technology with potential applications in the fields of high-capacity data storage, polarization-controlled optical elements, and other related fields. The choice of its high-performance materials is particularly important. To further develop polarization holography applications and improve the quality of the information recorded (i.e., material sensitivity and resolution), a deeper understanding of such materials is needed. We present an overview of the polarization-sensitive materials, which introduced polarization holographic technology and the development of polarization holographic materials. The three main types of polarization holographic materials are described, including azopolymer materials, photopolymer material, and photorefractive polymer material. We examine the key contributions of each work and present many of the suggestions that have been made to improve the different polarization-sensitive photopolymer materials.

16 August 2017 in Optics Express
Verified
Journal Article
Open access
PDF file
YLYing Liu
Ying Liu
FFFenglan Fan
Fenglan Fan
YHYifan Hong
Yifan Hong
JZJinliang Zang
Jinliang Zang
GKGuoguo Kang
Guoguo Kang
XTXiaodi Tan
Xiaodi Tan
Photoinitiator plays a crucial role on photopolymer. Unlike photoinitiator phenanthrenequinone (PQ), the solubility of Irgacure 784 dissolved in MMA is very high. In this paper, we use Irgacure 784 as photoinitiator doped in poly(methyl methacrylate)(PMMA)to make a bulk photopolymer with high photoinitiator concentration for holographic data storage. The effect of concentration of photoinitiator and record intensity are experimentally investigated. The results reveal the material has an optimum condition in holographic recording. A comparison between our material and the material of PQ doped PMMA is carried out by experiment. It is found that our material has better performance on diffraction efficiency, refractive index modulation and recording sensitivity. Besides, this material also has polarization sensitivity, which can be applied to polarization holography. With the capacity of recording polarization holography and conventional intensity holography simultaneously, the Irgacure 784 doped PMMA material is expected to be applied in holographic data storage.

24 August 2020 in Optics Express
Verified
Journal Article
Closed access
XFXiujie Fang
Xiujie Fang
KWKai Wei
Kai Wei
TZTian Zhao
Tian Zhao
YZYueyang Zhai
Yueyang Zhai
DMDanyue Ma
Danyue Ma
ZXZhisong Xiao
Zhisong Xiao
Ultra-sensitive multi-channel optically pumped atomic magnetometers based on the spin-exchange relaxation-free (SERF) effect are powerful tools for applications in the field of magnetic imaging. To simultaneously achieve ultra-high spatial resolution and ultra-high magnetic field sensitivity, we proposed a high-resolution multi-channel SERF atomic magnetometer for two-dimensional magnetic field measurements based on a digital micro-mirror device (DMD) as the spatial light modulator for a single vapor cell. Under the optimal experimental conditions obtained via spatial and temporal modulation of the probe light, we first demonstrated that the average sensitivity of the proposed 25-channel magnetometer was approximately 25fT/Hz1/2 with a spatial resolution of 216µm. Then, we measured the magnetic field distribution generated by a gradient coil and compared the experimentally obtained distributions with those calculated via finite element simulation. The obtained g value of 99.2% indicated good agreement between our experimental results and the theoretical calculations, thereby confirming that our proposed multi-channel SERF magnetometer was effective at measuring magnetic field distributions with an ultra-high spatial resolution.