23 November 2022 in IEEE Transactions on Geoscience and Remote Sensing
The non-destructive detection and monitoring of moisture content in asphalt concrete (AC) pavement is important, as moisture may cause adhesion failures between aggregates and asphalt, resulting in AC stripping and raveling. This paper introduces a novel deep residual network–Mois-ResNets–to predict the internal moisture content of AC pavement from ground-penetrating radar (GPR) measurements. A GPR signal database was established from field tests and numerical simulations. A developed heterogeneous numerical model was used to generate synthetic GPR signals by simulating asphalt pavements at various configurations, moisture contents, volumetrics, and dielectric properties. The Mois-ResNets model, which contains a short-time Fourier transform followed by a deep residual network, was trained to minimize the error between predicted moisture content level and ground-truth data. Testing results show that Mois-ResNets can achieve a classification accuracy of 91% on testing datasets, outperforming conventional machine learning methods. The proposed Mois-ResNets has the potential for using GPR measurements and deep learning methods for pavement internal moisture content prediction.
22 February 2024 in Transportation Research Record: Journal of the Transportation Research Board
Contractors are paid incentives/disincentives based on achieved in situ asphalt concrete (AC) density. Ground-penetrating radar (GPR) has been proven feasible for predicting in situ density of AC pavements using various empirical and fundamental approaches. However, to use fundamental equations for density prediction, aggregate dielectric constant must be known beforehand. Destructive cores are usually extracted from the pavement to back-calculate the aggregate dielectric constant. This cancels out the non-destructive benefit of the GPR technology. In this study, GPR is used to quantify the dielectric constant of 10 different aggregates commonly used in AC mixes in Illinois, U.S. The sampled aggregates included limestone, dolomite, trap rock, granite, and crushed gravel. The purpose was to initiate an aggregate dielectric constant database that would help predict AC density nondestructively and accurately. By using the aggregate database, GPR would help contractors estimate achieved density in real-time without prior calibration. This technology would save energy, time, and cost. Simulations using gprMax and a sensitivity analysis are presented to illustrate the effect of aggregate dielectric constant on AC bulk dielectric constant and, consequently, on AC density predicted by the Al-Qadi Lahouar Leng model. A new procedure to determine the aggregate dielectric constant using the electromagnetic mixing theory is detailed. Advanced chemical tests confirmed that the aggregate dielectric constant is a function of its elemental/mineral compositions. Finally, laboratory and field data were used to validate AC density prediction using the aggregate database. The establishment of an aggregate dielectric constant database would improve the accuracy of GPR in nondestructive AC density prediction.
23 March 2023 in International Journal of Pavement Engineering
Ground-penetrating radar (GPR) is a non-destructive testing technique used to assess various civil structures, including pavements. It may be applied to predict asphalt concrete (AC) layer thicknesses and dry densities. Because moisture may exist in in-service AC pavement layers and hinder the density prediction, quantifying moisture content in AC would improve its layer-density prediction. In addition, quantifying moisture content of cold recycled pavements would allow monitoring of the curing process of the treatment. Hence, the proper time for opening roads to traffic and/or placing an overlay could be identified. In this study, data were collected from both field cold-recycling projects and laboratory test slabs. The combined dataset was used to correlate measured moisture content to the dielectric constant of AC mixes. The Al-Qadi–Cao–Abufares (ACA) model was derived based on the electromagnetic mixing theory. This model is a modification to the Al-Qadi–Lahouar–Leng (ALL) model; it incorporates the effect of moisture on the bulk dielectric constant to predict density of non-dry AC. The model predicts AC density with an average error of 2% and also predicts moisture content with a root mean square error of 0.5%.
21 May 2022 in Transportation Research Record: Journal of the Transportation Research Board
Ground-penetrating radar (GPR) recently has been used for quality control and quality assurance of the asphalt concrete (AC) pavement-construction process. The objective of this study was to investigate the feasibility of estimating, by using GPR, the moisture content in AC pavement. This application is particularly important for emulsion-stabilized cold in-place recycling (CIR) and cold central-plant recycling (CCPR), where monitoring the moisture content is necessary for deciding the timing of opening the road to traffic, overlay placement, or both. Four field tests were performed using GPR on CIR- or CCPR-treated AC pavement. A numerical simulation model of AC pavement with internal moisture was generated using the information from mix design, and virtual GPR tests were performed using the finite-difference time-domain (FDTD) method. After calibration, a moisture-prediction formula derived from the simulation model was used to correlate the dielectric constant predicted by GPR to the moisture content within cold recycled layers. The GPR signal was “denoised” by improving its stability and mitigating the measured-height mismatch. The in-situ moisture content was predicted using the proposed method and compared with field-collected samples. Results showed that the proposed method is effective in estimating CIR- and CCPR-layer moisture content. The variation of dielectric constants in field tests is also discussed. A testing protocol for predicting moisture content using GPR is suggested for CIR and CCPR pavement.
27 May 2025 in Transportation Research Record: Journal of the Transportation Research Board
A prevalent application of ground-penetrating radar (GPR) for asphalt concrete (AC) pavements is predicting in-situ density, which is an important pavement quality parameter. Accurate estimation of the dielectric constant is required when using GPR for pavement inspections. Surface moisture is a challenge because it masks the GPR reflection amplitudes. Surface moisture could result from natural rainfall events or from sprayed water by roller compactors during AC construction. This study introduces an efficient method to filter GPR signals from surface moisture effects while maintaining density information intact. Through numerical simulations and laboratory testing data, the surface moisture effect was isolated. A singular value decomposition-based signal correction approach was proposed. Data from six different AC sections were utilized to develop the correction algorithm. Finally, for validation, the developed algorithm was applied to GPR scans collected in two extreme conditions: dry and wet, which were collected on another AC pavement before and after a rain event. Results supported the need for surface moisture correction, especially for AC density monitoring during compaction. After applying the correction, the mean absolute error (MAE) of dielectric constant estimation (used to predict AC density) dropped from 16% to 2.6% and, therefore, the AC density prediction MAE dropped from 8.9% to 1.3%.