Trapti Jain

Trapti Jain

Auto-generated profile, based on publicly available information

Trapti Jain

Electrical Engineering, Indian Institute of Technology Indore, Indore, INDIA

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 November 2016 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
KTKarthik Thirumala
Karthik Thirumala
MPM. Siva Prasad
M. Siva Prasad
TJTrapti Jain
Trapti Jain
AUAmod C. Umarikar
Amod C. Umarikar
A new automated recognition approach based on tunable-Q wavelet transform (TQWT) and a dual multiclass support vector machines (MSVM) has been proposed for detection of power quality disturbances. The proposed approach first investigates the presence of low-frequency interharmonics and then tunes the wavelet for decomposition of signal into fundamental and harmonic components. The tuning of Q-factor and redundancy makes the filter design to accurately extract the fundamental frequency component from a distorted input signal. Then, a unique set of features, which clearly reveal the characteristics of disturbances, are extracted. The power quality disturbances are broadly categorized into two groups based on the pre-obtained information of low-frequency interharmonics. Therefore, multiple disturbances are recognized by employing a dual MSVM, one for each group. Results demonstrate the applicability, strength and accuracy of the proposed approach for classification of single and combined disturbances under different noisy conditions. Moreover, to illustrate the prominence of the features extracted from TQWT, two more classifiers based on decision tree and feedforward neural network have been employed for classification of power quality disturbances.

25 October 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
VTVinay K. Tiwari
Vinay K. Tiwari
AUAmod C. Umarikar
Amod C. Umarikar
TJTrapti Jain
Trapti Jain
Accurate and fast estimation of time-varying harmonics are essential requirements for online monitoring, analysis, and control of electrical power system. This paper presents a fast algorithm based on the undecimated wavelet packet transform (UWPT) to estimate the amplitude of fundamental and harmonic components of stationary as well as a time-varying power signal. The UWPT uses only one cycle of the fundamental frequency for precise measurement of time-varying harmonics while their amplitude has been determined accurately utilizing the time-invariant property of the UWPT. The robustness and accuracy of the proposed technique have been investigated on synthetic as well as experimental test signals using MATLAB tool. Further, the UWPT algorithm has also been implemented on the Xilinx Virtex-6 FPGA ML-605 board, using XSG/ISE design suite 14.2 and its performance, in terms of hardware accuracy, resource utilization as well as timing requirements have been tested using the experimental test signal.

24 September 2018 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
EPE S N Raju Paidi
E S N Raju Paidi
TJTrapti Jain
Trapti Jain
This paper proposes phasor measurement units (PMUs) supported two-level hierarchical controller to enhance stability and dynamic performance of islanded inverter-based microgrids (IIMGs) with static and dynamic loads. The proposed hierarchical controller consists of a local decentralized controller for each inverter-interfaced distributed generation (IIDG) unit at the primary level helped by a multi-input multi-output (MIMO) centralized controller at the secondary level. The primary-level decentralized controller incorporates the addition of auxiliary control terms to the conventional droop controller. The auxiliary control terms are based on the total real and reactive power generation information acquired from wide area measurement system (WAMS) through PMUs and the desired power sharing of each IIDG unit. The secondary-level centralized controller, on the other hand, enhances the performance of each local decentralized controller by compensating the voltage and frequency deviations caused by the load disturbances. The performance of the proposed hierarchical controller has been demonstrated through eigenvalue analysis and time-domain simulation results carried out in MATLAB/SIMULINK environment. Further, in order to have a fair comparison, the performance of the proposed hierarchical controller, based on modal-based extended LQG approach, has been compared with that of hierarchical controller based on state-based extended LQG approach. Simulation results revealed the capability of the proposed hierarchical controller to mitigate the unstable oscillations as well as to settle quickly at different operating

4 September 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
VTVinay K. Tiwari
Vinay K. Tiwari
AUAmod C. Umarikar
Amod C. Umarikar
TJTrapti Jain
Trapti Jain
This paper presents a measurement technique based on the undecimated wavelet packet transform (UWPT) and Hilbert transform (HT) to estimate power quality parameters at every sample. Thus, it results in improved time resolution and allows us to track the variation of power quality parameters with respect to time. The proposed technique consists of three stages. In the first stage, harmonics and fundamental components are separated from the distorted signal using UWPT. In the second stage, the Hilbert transform is used to extract the envelope of fundamental and harmonic components. In the last stage, power quality parameters are calculated at each instant according to IEEE Standard 1459-2010. The proposed scheme has been successfully implemented on the Xilinx Virtex-6 FPGA ML-605 evaluation kit. The simulation, as well as the experimental results demonstrate the effectiveness of the proposed method in terms of estimation accuracy, timing requirements and resource utilization.

30 August 2021 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
AIAdnan Iqbal
Adnan Iqbal
TJTrapti Jain
Trapti Jain
The proliferation of Phasor Measurement Units (PMUs) to monitor power grid dynamics at a high resolution (10–100 samples/sec) has opened a new paradigm to situational awareness. Existing event detection techniques for identifying multiple events like transmission line faults, generation trip, line trip, load loss, current transformer (CT) failure, islanding, etc., are prone to misdetection, delayed detection, and false detection. Moreover, most of them can detect events either with fast (transient events) or slow dynamics (oscillatory and excursion events) using synchrophasor measurements. This paper focuses on detecting events with both fast and slow dynamics using wide-area frequency measurements. To this end, a novel method is proposed based on Weibull distribution, which we call as Weibull-based Excursion Transient and Oscillatory (WETO) method. The WETO method can identify the time of inception, location, and severity of the event in near real-time using only a single parameter, known as variability. The events are detected within a time window of 5 cycles using only frequency measurements. The proposed method is validated for the Indian as well as the North American grid disturbances, and the results show that it would be beneficial to the system operator in visualizing the true situation of the grid events.

1 March 2019
Verified
Conference Paper
Closed access
TJTrapti Jain
Trapti Jain
NJNakul Jain
Nakul Jain
In the current era, Digitization has taken day-to-day utilities starting from a cab to grossary on the internet. All the service providers heavily leverage IT and IT Services. Web Application plays a significant role in providing these services. While Digital opens infinite opportunities to increase business and enhance delivery, it also exposes business to an unseen world of cyber-attacks. To prevent the business from digital dysfunctioning, organizations pro-actively and continuously perform Vulnerability Assessments & Penetration Tests on their IT Assets (i.e. Web Applications, Network Devices, Servers, Security Devices, etc.). However, quite often such scans become time consuming and generate unreliable results and none of the tools can find out the effective vulnerability. However, with a set of combined tools in one framework, it is possible to increase the coverage of vulnerability issues. The aim of the research is to present two approaches: (1) Web application vulnerability discovery through a set of web application vulnerability scanners and its integration on the same framework (python as scripting engine) using multi-threading technique (to reduce the scan time). (2) Mitigation of the detected web application vulnerabilities by customizing configuration rules through web application firewall ModSecurity.