Increased penetration of power electronics interfaced renewable energy sources-based generation, for instance, wind farms, that displaces much of the conventional synchronous generation, has a profound effect on the inertia of modern/future power system networks. This article presents the development and validation of artificial neural network (ANN)-based tools, utilizing the power system variables measured by phasor measurement units through wide-area measurements systems, for estimation/forecasting of power system inertia with high penetration of wind farms. The development stage involves the correlation analysis to identify the best power system variables that can be nominated as inputs, and the training of the proposed inertia forecasting tools with the best-nominated inputs that are highly correlated with the power system inertia. Whereas, in the validation stage, the functionality of the trained ANN-based inertia forecasting tools have been validated using the hardware-in-the-loop testing facility developed at the University of Manchester. The development and validation procedures of the proposed inertia forecasting tools have been demonstrated on the IEEE 9-bus modified test system. The validation results revealed the effectiveness of the proposed inertia forecasting tools in estimating the inertia of modern/future power system networks with high penetration of wind farms.
24 September 2018 in IEEE Transactions on Industrial Informatics
This paper proposes phasor measurement units (PMUs) supported two-level hierarchical controller to enhance stability and dynamic performance of islanded inverter-based microgrids (IIMGs) with static and dynamic loads. The proposed hierarchical controller consists of a local decentralized controller for each inverter-interfaced distributed generation (IIDG) unit at the primary level helped by a multi-input multi-output (MIMO) centralized controller at the secondary level. The primary-level decentralized controller incorporates the addition of auxiliary control terms to the conventional droop controller. The auxiliary control terms are based on the total real and reactive power generation information acquired from wide area measurement system (WAMS) through PMUs and the desired power sharing of each IIDG unit. The secondary-level centralized controller, on the other hand, enhances the performance of each local decentralized controller by compensating the voltage and frequency deviations caused by the load disturbances. The performance of the proposed hierarchical controller has been demonstrated through eigenvalue analysis and time-domain simulation results carried out in MATLAB/SIMULINK environment. Further, in order to have a fair comparison, the performance of the proposed hierarchical controller, based on modal-based extended LQG approach, has been compared with that of hierarchical controller based on state-based extended LQG approach. Simulation results revealed the capability of the proposed hierarchical controller to mitigate the unstable oscillations as well as to settle quickly at different operating
20 May 2019 in IEEE Transactions on Power Delivery
This paper presents the development and validation of a new oscillatory component load (OCL) model for a measurement-based real-time estimation of dynamic load model parameters. The proposed OCL model has been derived from a second-order differential equation that considers three necessary components, namely static, exponential recovery, and damped oscillatory components. The performance evaluation of the proposed OCL model has been demonstrated through DIgSILENT PowerFactory-based dynamic power system simulations, real-time substation data captured from phasor measurement units located at the primary substations of Leadenham, Holwell, and Regent Street cities, and real-time transient voltage events data provided by the EirGrid. Further, the effectiveness of the proposed OCL model has been assessed by comparing its performance with that of the existing exponential recovery load model. A new flexible and efficient SynchroHub platform, developed at the University of Manchester for real-time data acquisition, processing and visualization, has been used for the real-time estimation of dynamic load model parameters. The validation results revealed the efficacy of the proposed OCL model in tracking both the first as well as the subsequent oscillations of dynamic load model response of the power system for both the steady state as well as transient operating conditions accurately.
11 July 2025 in IEEE Transactions on Consumer Electronics
The growing penetration of Distributed Generators (DGs) results in a reduction of grid inertia. Low inertia poses significant challenges, particularly in the islanded mode of operation. To address this issue, one promising solution is to emulate the physical inertia of a synchronous generator in the power electronics control of the inverter. Among the various schemes proposed in the literature, a virtual synchronous generator (VSG) is well known. A VSG control provides inertia support by implementing the rotor dynamics of a synchronous machine in power electronics control. In VSGs, the average power obtained from the low pass filter (LPF) is used as feedback for the virtual torque equation. The cutoff frequency of the LPF limits bandwidth and decelerates dynamic response. To overcome this limitation, a compensator-based VSG has been proposed in this paper, which gives more flexibility in tuning the bandwidth of the controller. This reduces the tuning effort of controller gains in voltage and current control and improves small signal stability. Apart from the compensator, an additional damping loop is also included to suppress oscillations during disturbances. The small signal model (SSM) of the VSG was derived and incorporated into the microgrid model. The developed model was validated through eigenvalue analysis, time domain, and real-time simulations along with controller hardware in loop (CHIL) implementation. VSG-operated microgrid small signal stability was analyzed by feeding different types of loads like passive load, active load, and dynamic induction motor load. The effectiveness of VSG was established by comparing its performance with conventional droop control. The proposed VSG was found to outperform the conventional droop control in the presence of rectifier interfaced active load and constant power load.