Gregory A. Clark

Gregory A. Clark

Auto-generated profile, based on publicly available information

Gregory A. Clark

Biomedical Engineering, University of Utah, 36 S Wasatch Dr, Salt Lake City, Utah, 84112, UNITED STATES

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2019 in Science Robotics
Verified
Journal Article
Closed access
PDF file
JGJ. A. George
J. A. George
DKD. T. Kluger
D. T. Kluger
TDT. S. Davis
T. S. Davis
SWS. M. Wendelken
S. M. Wendelken
EOE. V. Okorokova
E. V. Okorokova
GCG. A. Clark
G. A. Clark
Sensory feedback improves dexterous use of a bionic arm, and sensory signals that mimic natural ones are more intuitive and useful.

25 November 2017 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
SWSuzanne Wendelken
Suzanne Wendelken
DPDavid M. Page
David M. Page
TDTyler Davis
Tyler Davis
HWHeather A. C. Wark
Heather A. C. Wark
DKDavid T. Kluger
David T. Kluger
GCGregory A. Clark
Gregory A. Clark
Despite advances in sophisticated robotic hands, intuitive control of and sensory feedback from these prostheses has been limited to only 3-degrees-of-freedom (DOF) with 2 sensory percepts in closed-loop control. A Utah Slanted Electrode Array (USEA) has been used in the past to provide up to 81 sensory percepts for human amputees. Here, we report on the advanced capabilities of multiple USEAs implanted in the residual peripheral arm nerves of human amputees for restoring control of 5 DOF and sensation of up to 131 proprioceptive and cutaneous hand sensory percepts. We also demonstrate that USEA-restored sensory percepts provide a useful source of feedback during closed-loop virtual prosthetic hand control. Two 100-channel USEAs were implanted for 4–5 weeks, one each in the median and ulnar arm nerves of two human subjects with prior long-duration upper-arm amputations. Intended finger and wrist positions were decoded from neuronal firing patterns via a modified Kalman filter, allowing subjects to control many movements of a virtual prosthetic hand. Additionally, USEA microstimulation was used to evoke numerous sensory percepts spanning the phantom hand. Closed-loop control was achieved by stimulating via an electrode of the ulnar-nerve USEA while recording and decoding movement via the median-nerve USEA. Subjects controlled up to 12 degrees-of-freedom during informal, ‘freeform’ online movement decode sessions, and experienced up to 131 USEA-evoked proprioceptive and cutaneous sensations spanning the phantom hand. Independent control was achieved for a 5-DOF real-time decode that included flexion/extension of the thumb, index, middle, and ring fingers, and the wrist. Proportional control was achieved for a 4-DOF real-time decode. One subject used a USEA-evoked hand sensation as feedback to complete a 1-DOF closed-loop virtual-hand movement task. There were no observed long-term functional deficits due to the USEA implants. Implantation of high-channel-count USEAs enables multi-degree-of-freedom control of virtual prosthetic hand movement and restoration of a rich selection of both proprioceptive and cutaneous sensory percepts spanning the hand during the short 4–5 week post-implant period. Future USEA use in longer-term implants and in closed-loop may enable restoration of many of the capabilities of an intact hand while contributing to a meaningful embodiment of the prosthesis.

21 September 2018 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
PDF file
DPDavid M. Page
David M. Page
JGJacob A. George
Jacob A. George
DKDavid T. Kluger
David T. Kluger
CDChristopher Duncan
Christopher Duncan
SWSuzanne Wendelken
Suzanne Wendelken
GCGregory A. Clark
Gregory A. Clark
We quantified prosthesis embodiment and phantom pain reduction associated with motor control and sensory feedback from a prosthetic hand in one human with a long-term transradial amputation. Microelectrode arrays were implanted in the residual median and ulnar arm nerves and intramuscular electromyography recording leads were implanted in residual limb muscles to enable sensory feedback and motor control. Objective measures (proprioceptive drift) and subjective measures (survey answers) were used to assess prosthesis embodiment. For both measures, there was a significant level of embodiment of the physical prosthetic limb after open-loop motor control of the prosthesis (i.e., without sensory feedback), open-loop sensation from the prosthesis (i.e., without motor control), and closed-loop control of the prosthesis (i.e., motor control with sensory feedback). There was also a statistically significant reduction in reported phantom pain after experimental sessions that included open-loop nerve microstimulation, open-loop prosthesis motor control, or closed-loop prosthesis motor control. The closed-loop condition provided no additional significant improvements in phantom pain reduction or prosthesis embodiment relative to the open-loop sensory condition or the open-loop motor condition. This study represents the first long-term (14-month), systematic report of phantom pain reduction and prosthesis embodiment in a human amputee across a variety of prosthesis use cases.

1 January 2020 in Journal of Neuroscience Methods
Verified
Journal Article
Open access
JGJacob A. George
Jacob A. George
TDTyler S. Davis
Tyler S. Davis
MBMark R. Brinton
Mark R. Brinton
GCGregory A. Clark
Gregory A. Clark
Multi-articulate prostheses are capable of performing dexterous hand movements. However, clinically available control strategies fail to provide users with intuitive, independent and proportional control over multiple degrees of freedom (DOFs) in real-time. We detail the use of a modified Kalman filter (MKF) to provide intuitive, independent and proportional control over six-DOF prostheses such as the DEKA "LUKE" arm. Input features include neural firing rates recorded from Utah Slanted Electrode Arrays and mean absolute value of intramuscular electromyographic (EMG) recordings. Ad-hoc modifications include thresholds and non-unity gains on the output of a Kalman filter. We demonstrate that both neural and EMG data can be combined effectively. We also highlight that modifications can be optimized to significantly improve performance relative to an unmodified Kalman filter. Thresholds significantly reduced unintended movement and promoted more independent control of the different DOFs. Gains were significantly greater than one and served to ease movement initiation. Optimal modifications can be determined quickly offline and translate to functional improvements online. Using a portable take-home system, participants performed various activities of daily living. In contrast to pattern recognition, the MKF allows users to continuously modulate their force output, which is critical for fine dexterity. The MKF is also computationally efficient and can be trained in less than five minutes. The MKF can be used to explore the functional and psychological benefits associated with long-term, at-home control of dexterous prosthetic hands.

15 January 2013 in Journal of Neurophysiology
Verified
Journal Article
Open access
PDF file
NLNoah M. Ledbetter
Noah M. Ledbetter
CEChristian Ethier
Christian Ethier
EOEmily R. Oby
Emily R. Oby
SHScott D. Hiatt
Scott D. Hiatt
AWAndrew M. Wilder
Andrew M. Wilder
GCGregory A. Clark
Gregory A. Clark
High-count microelectrode arrays implanted in peripheral nerves could restore motor function after spinal cord injury or sensory function after limb loss. In this study, we implanted Utah Slanted Electrode Arrays (USEAs) intrafascicularly at the elbow or shoulder in arm nerves of rhesus monkeys (n = 4) under isoflurane anesthesia. Input-output curves indicated that pulse-width-modulated single-electrode stimulation in each arm nerve could recruit single muscles with little or no recruitment of other muscles. Stimulus trains evoked specific, natural, hand movements, which could be combined via multielectrode stimulation to elicit coordinated power or pinch grasp. Stimulation also elicited short-latency evoked potentials (EPs) in primary somatosensory cortex, which might be used to provide sensory feedback from a prosthetic limb. These results demonstrate a high-resolution, high-channel-count interface to the peripheral nervous system for restoring hand function after neural injury or disruption or for examining nerve structure.

1 August 2011
Verified
Conference Paper
Closed access
GCGregory A. Clark
Gregory A. Clark
NLNoah M. Ledbetter
Noah M. Ledbetter
DWDavid J. Warren
David J. Warren
RHReid R. Harrison
Reid R. Harrison
Recording and stimulation via high-count penetrating microelectrode arrays implanted in peripheral nerves may help restore precise motor and sensory function after nervous system damage or disease. Although previous work has demonstrated safety and relatively successful stimulation for long-term implants of 100-electrode Utah Slanted Electrode Arrays (USEAs) in feline sciatic nerve [1], two major remaining challenges were 1) to maintain viable recordings of nerve action potentials long-term, and 2) to overcome contamination of unit recordings by myoelectric (EMG) activity in awake, moving animals. In conjunction with improvements to USEAs themselves, we have redesigned several aspects of our USEA containment and connector systems. Although further increases in unit yield and long-term stability remain desirable, here we report considerable progress toward meeting both of these goals: We have successfully recorded unit activity from USEAs implanted intrafascicularly in sciatic nerve for periods up to 4 months (the terminal experimental time point), and we have developed a containment system that effectively eliminates or substantially reduces EMG contamination of unit recordings in the moving animal. In addition, we used a 100-channel wireless recording integrated circuit attached to implanted USEAs to transmit broadband or spike-threshold data from nerve. Neural data thusly obtained during imposed limb movements were decoded blindly to drive a virtual prosthetic limb in real time. These results support the possibility of using USEAs in peripheral nerves to provide motor control and cutaneous or proprioceptive sensory feedback in individuals after limb loss or spinal cord injury.