Tyler S. Davis

Tyler S. Davis

Auto-generated profile, based on publicly available information

Tyler S. Davis

Department of Neurosurgery, University of Utah

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2019 in Science Robotics
Verified
Journal Article
Closed access
PDF file
JGJ. A. George
J. A. George
DKD. T. Kluger
D. T. Kluger
TDT. S. Davis
T. S. Davis
SWS. M. Wendelken
S. M. Wendelken
EOE. V. Okorokova
E. V. Okorokova
GCG. A. Clark
G. A. Clark
Sensory feedback improves dexterous use of a bionic arm, and sensory signals that mimic natural ones are more intuitive and useful.

1 December 2021 in Journal of Clinical Investigation
Verified
Journal Article
Closed access
PDF file
EFEduardo Buglioni Fernandez
Eduardo Buglioni Fernandez
AAArantxa Alfaro
Arantxa Alfaro
CSCristina Soto-Sánchez
Cristina Soto-Sánchez
PGPablo Gonzalez-Lopez
Pablo Gonzalez-Lopez
ALAntonio M. Lozano
Antonio M. Lozano
RNRichard A. Normann
Richard A. Normann
BACKGROUND. A long-held goal of vision therapy is to transfer information directly to the visual cortex of blind individuals, thereby restoring a rudimentary form of sight. However, no clinically available cortical visual prosthesis yet exists. METHODS. We implanted an intracortical microelectrode array consisting of 96 electrodes in the visual cortex of a 57-year-old person with complete blindness for a 6-month period. We measured thresholds and the characteristics of the visual percepts elicited by intracortical microstimulation. RESULTS. Implantation and subsequent explantation of intracortical microelectrodes were carried out without complications. The mean stimulation threshold for single electrodes was 66.8 ± 36.5 μA. We consistently obtained high-quality recordings from visually deprived neurons and the stimulation parameters remained stable over time. Simultaneous stimulation via multiple electrodes was associated with a significant reduction in thresholds (P < 0.001, ANOVA) and evoked discriminable phosphene percepts, allowing the blind participant to identify some letters and recognize object boundaries. CONCLUSIONS. Our results demonstrate the safety and efficacy of chronic intracortical microstimulation via a large number of electrodes in human visual cortex, showing its high potential for restoring functional vision in the blind. TRIAL REGISTRATION. ClinicalTrials.gov identifier NCT02983370. FUNDING. The Spanish Ministerio de Ciencia Innovación y Universidades, the Generalitat Valenciana (Spain), the Europan Union’s Horizon 2020 programme, the Bidons Egara Research Chair of the University Miguel Hernández (Spain), and the John Moran Eye Center of the University of Utah.

25 November 2017 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
SWSuzanne Wendelken
Suzanne Wendelken
DPDavid M. Page
David M. Page
TDTyler Davis
Tyler Davis
HWHeather A. C. Wark
Heather A. C. Wark
DKDavid T. Kluger
David T. Kluger
GCGregory A. Clark
Gregory A. Clark
Despite advances in sophisticated robotic hands, intuitive control of and sensory feedback from these prostheses has been limited to only 3-degrees-of-freedom (DOF) with 2 sensory percepts in closed-loop control. A Utah Slanted Electrode Array (USEA) has been used in the past to provide up to 81 sensory percepts for human amputees. Here, we report on the advanced capabilities of multiple USEAs implanted in the residual peripheral arm nerves of human amputees for restoring control of 5 DOF and sensation of up to 131 proprioceptive and cutaneous hand sensory percepts. We also demonstrate that USEA-restored sensory percepts provide a useful source of feedback during closed-loop virtual prosthetic hand control. Two 100-channel USEAs were implanted for 4–5 weeks, one each in the median and ulnar arm nerves of two human subjects with prior long-duration upper-arm amputations. Intended finger and wrist positions were decoded from neuronal firing patterns via a modified Kalman filter, allowing subjects to control many movements of a virtual prosthetic hand. Additionally, USEA microstimulation was used to evoke numerous sensory percepts spanning the phantom hand. Closed-loop control was achieved by stimulating via an electrode of the ulnar-nerve USEA while recording and decoding movement via the median-nerve USEA. Subjects controlled up to 12 degrees-of-freedom during informal, ‘freeform’ online movement decode sessions, and experienced up to 131 USEA-evoked proprioceptive and cutaneous sensations spanning the phantom hand. Independent control was achieved for a 5-DOF real-time decode that included flexion/extension of the thumb, index, middle, and ring fingers, and the wrist. Proportional control was achieved for a 4-DOF real-time decode. One subject used a USEA-evoked hand sensation as feedback to complete a 1-DOF closed-loop virtual-hand movement task. There were no observed long-term functional deficits due to the USEA implants. Implantation of high-channel-count USEAs enables multi-degree-of-freedom control of virtual prosthetic hand movement and restoration of a rich selection of both proprioceptive and cutaneous sensory percepts spanning the hand during the short 4–5 week post-implant period. Future USEA use in longer-term implants and in closed-loop may enable restoration of many of the capabilities of an intact hand while contributing to a meaningful embodiment of the prosthesis.

1 January 2020 in Journal of Neuroscience Methods
Verified
Journal Article
Open access
JGJacob A. George
Jacob A. George
TDTyler S. Davis
Tyler S. Davis
MBMark R. Brinton
Mark R. Brinton
GCGregory A. Clark
Gregory A. Clark
Multi-articulate prostheses are capable of performing dexterous hand movements. However, clinically available control strategies fail to provide users with intuitive, independent and proportional control over multiple degrees of freedom (DOFs) in real-time. We detail the use of a modified Kalman filter (MKF) to provide intuitive, independent and proportional control over six-DOF prostheses such as the DEKA "LUKE" arm. Input features include neural firing rates recorded from Utah Slanted Electrode Arrays and mean absolute value of intramuscular electromyographic (EMG) recordings. Ad-hoc modifications include thresholds and non-unity gains on the output of a Kalman filter. We demonstrate that both neural and EMG data can be combined effectively. We also highlight that modifications can be optimized to significantly improve performance relative to an unmodified Kalman filter. Thresholds significantly reduced unintended movement and promoted more independent control of the different DOFs. Gains were significantly greater than one and served to ease movement initiation. Optimal modifications can be determined quickly offline and translate to functional improvements online. Using a portable take-home system, participants performed various activities of daily living. In contrast to pattern recognition, the MKF allows users to continuously modulate their force output, which is critical for fine dexterity. The MKF is also computationally efficient and can be trained in less than five minutes. The MKF can be used to explore the functional and psychological benefits associated with long-term, at-home control of dexterous prosthetic hands.

9 December 2021 in Frontiers in Neuroscience
Verified
Journal Article
Open access
TDTyler S. Davis
Tyler S. Davis
RCRose M. Caston
Rose M. Caston
BPBrian Philip
Brian Philip
CCChantel M. Charlebois
Chantel M. Charlebois
DADaria Nesterovich Anderson
Daria Nesterovich Anderson
JRJohn D. Rolston
John D. Rolston
Accurate anatomical localization of intracranial electrodes is important for identifying the seizure foci in patients with epilepsy and for interpreting effects from cognitive studies employing intracranial electroencephalography. Localization is typically performed by coregistering postimplant computed tomography (CT) with preoperative magnetic resonance imaging (MRI). Electrodes are then detected in the CT, and the corresponding brain region is identified using the MRI. Many existing software packages for electrode localization chain together separate preexisting programs or rely on command line instructions to perform the various localization steps, making them difficult to install and operate for a typical user. Further, many packages provide solutions for some, but not all, of the steps needed for confident localization. We have developed software, Locate electrodes Graphical User Interface (LeGUI), that consists of a single interface to perform all steps needed to localize both surface and depth/penetrating intracranial electrodes, including coregistration of the CT to MRI, normalization of the MRI to the Montreal Neurological Institute template, automated electrode detection for multiple types of electrodes, electrode spacing correction and projection to the brain surface, electrode labeling, and anatomical targeting. The software is written in MATLAB, core image processing is performed using the Statistical Parametric Mapping toolbox, and standalone executable binaries are available for Windows, Mac, and Linux platforms. LeGUI was tested and validated on 51 datasets from two universities. The total user and computational time required to process a single dataset was approximately 1 h. Automatic electrode detection correctly identified 4362 of 4695 surface and depth electrodes with only 71 false positives. Anatomical targeting was verified by comparing electrode locations from LeGUI to locations that were assigned by an experienced neuroanatomist. LeGUI showed a 94% match with the 482 neuroanatomist-assigned locations. LeGUI combines all the features needed for fast and accurate anatomical localization of intracranial electrodes into a single interface, making it a valuable tool for intracranial electrophysiology research.

26 February 2019 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
HDHenrique Dantas
Henrique Dantas
DWDavid J. Warren
David J. Warren
SWSuzanne M. Wendelken
Suzanne M. Wendelken
TDTyler S. Davis
Tyler S. Davis
GCGregory A. Clark
Gregory A. Clark
VMV John Mathews
V John Mathews
The performance of traditional approaches to decoding movement intent from electromyograms (EMGs) and other biological signals commonly degrade over time. Furthermore, conventional algorithms for training neural network based decoders may not perform well outside the domain of the state transitions observed during training. The work presented in this paper mitigates both these problems, resulting in an approach that has the potential to substantially improve the quality of life of the people with limb loss. This paper presents and evaluates the performance of four decoding methods for volitional movement intent from intramuscular EMG signals. The decoders are trained using the dataset aggregation (DAgger) algorithm, in which the training dataset is augmented during each training iteration based on the decoded estimates from previous iterations. Four competing decoding methods, namely polynomial Kalman filters (KFs), multilayer perceptron (MLP) networks, convolutional neural networks (CNN), and long short-term memory (LSTM) networks, were developed. The performances of the four decoding methods were evaluated using EMG datasets recorded from two human volunteers with transradial amputation. Short-term analyses, in which the training and cross-validation data came from the same dataset, and long-term analyses, in which the training and testing were done in different datasets, were performed. Short-term analyses of the decoders demonstrated that CNN and MLP decoders performed significantly better than KF and LSTM decoders, showing an improvement of up to 60% in the normalized mean-square decoding error in cross-validation tests. Long-term analyses indicated that the CNN, MLP, and LSTM decoders performed significantly better than a KF-based decoder at most analyzed cases of temporal separations (0-150 days) between the acquisition of the training and testing datasets. The short-term and long-term performances of MLP- and CNN-based decoders trained with DAgger demonstrated their potential to provide more accurate and naturalistic control of prosthetic hands than alternate approaches.