David T. Kluger

David T. Kluger

Auto-generated profile, based on publicly available information

David T. Kluger

Department of Biomedical Engineering, University of Utah, Salt Lake City, Utah, USA, 84112

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2019 in Science Robotics
Verified
Journal Article
Closed access
PDF file
JGJ. A. George
J. A. George
DKD. T. Kluger
D. T. Kluger
TDT. S. Davis
T. S. Davis
SWS. M. Wendelken
S. M. Wendelken
EOE. V. Okorokova
E. V. Okorokova
GCG. A. Clark
G. A. Clark
Sensory feedback improves dexterous use of a bionic arm, and sensory signals that mimic natural ones are more intuitive and useful.

25 November 2017 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
SWSuzanne Wendelken
Suzanne Wendelken
DPDavid M. Page
David M. Page
TDTyler Davis
Tyler Davis
HWHeather A. C. Wark
Heather A. C. Wark
DKDavid T. Kluger
David T. Kluger
GCGregory A. Clark
Gregory A. Clark
Despite advances in sophisticated robotic hands, intuitive control of and sensory feedback from these prostheses has been limited to only 3-degrees-of-freedom (DOF) with 2 sensory percepts in closed-loop control. A Utah Slanted Electrode Array (USEA) has been used in the past to provide up to 81 sensory percepts for human amputees. Here, we report on the advanced capabilities of multiple USEAs implanted in the residual peripheral arm nerves of human amputees for restoring control of 5 DOF and sensation of up to 131 proprioceptive and cutaneous hand sensory percepts. We also demonstrate that USEA-restored sensory percepts provide a useful source of feedback during closed-loop virtual prosthetic hand control. Two 100-channel USEAs were implanted for 4–5 weeks, one each in the median and ulnar arm nerves of two human subjects with prior long-duration upper-arm amputations. Intended finger and wrist positions were decoded from neuronal firing patterns via a modified Kalman filter, allowing subjects to control many movements of a virtual prosthetic hand. Additionally, USEA microstimulation was used to evoke numerous sensory percepts spanning the phantom hand. Closed-loop control was achieved by stimulating via an electrode of the ulnar-nerve USEA while recording and decoding movement via the median-nerve USEA. Subjects controlled up to 12 degrees-of-freedom during informal, ‘freeform’ online movement decode sessions, and experienced up to 131 USEA-evoked proprioceptive and cutaneous sensations spanning the phantom hand. Independent control was achieved for a 5-DOF real-time decode that included flexion/extension of the thumb, index, middle, and ring fingers, and the wrist. Proportional control was achieved for a 4-DOF real-time decode. One subject used a USEA-evoked hand sensation as feedback to complete a 1-DOF closed-loop virtual-hand movement task. There were no observed long-term functional deficits due to the USEA implants. Implantation of high-channel-count USEAs enables multi-degree-of-freedom control of virtual prosthetic hand movement and restoration of a rich selection of both proprioceptive and cutaneous sensory percepts spanning the hand during the short 4–5 week post-implant period. Future USEA use in longer-term implants and in closed-loop may enable restoration of many of the capabilities of an intact hand while contributing to a meaningful embodiment of the prosthesis.

2 April 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
DKDavid T. Kluger
David T. Kluger
JJJanell S. Joyner
Janell S. Joyner
SWSuzanne M. Wendelken
Suzanne M. Wendelken
TDTyler S. Davis
Tyler S. Davis
JGJacob A. George
Jacob A. George
GCGregory A. Clark
Gregory A. Clark
Although recent advances in neuroprostheses offer opportunities for improved and intuitive control of advanced motorized and sensorized robotic arms, practical complications associated with such hardware can impede the research necessary for clinical translation. These hurdles potentially can be reduced with virtual reality environments (VREs) with embedded physics engines using virtual models of physical robotic hands. These software suites offer several advantages over physical prototypes, including high repeatability, reduced human error, elimination of many secondary sensory cues, and others. There are limited demonstrations of closed-loop prostheses in a VRE, and it is unclear whether VRE performance translates to the physical world. Here we describe how two transradial amputees with neural and intramuscular implants identified objects and performed activities of daily living with closed-loop control of prostheses in a VRE. Our initial evidence further suggests that capabilities with virtual prostheses may be predictors of physical prosthesis performance, demonstrating the utility of VREs for neuroprosthetic research.

12 September 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
MPMichael D. Paskett
Michael D. Paskett
NONathaniel R. Olsen
Nathaniel R. Olsen
JGJacob A. George
Jacob A. George
DKDavid T. Kluger
David T. Kluger
MBMark R. Brinton
Mark R. Brinton
GCGregory A. Clark
Gregory A. Clark
Bypass sockets allow researchers to perform tests of prosthetic systems from the prosthetic user’s perspective. We designed a modular upper-limb bypass socket with 3D-printed components that can be easily modified for use with a variety of terminal devices. Our bypass socket preserves access to forearm musculature and the hand, which are necessary for surface electromyography and to provide substituted sensory feedback. Our bypass socket allows a sufficient range of motion to complete tasks in the frontal working area, as measured on non-amputee participants. We examined the performance of non-amputee participants using the bypass socket on the original and modified Box and Block Tests. Participants moved 11.3 ± 2.7 and 11.7 ± 2.4 blocks in the original and modified Box and Block Tests (mean ± SD), respectively, within the range of reported scores using amputee participants. Range-of-motion for users wearing the bypass socket meets or exceeds most reported range-of-motion requirements for activities of daily living. The bypass socket was originally designed with a freely rotating wrist; we found that adding elastic resistance to user wrist rotation while wearing the bypass socket had no significant effect on motor decode performance. We have open-sourced the design files and an assembly manual for the bypass socket. We anticipate that the bypass socket will be a useful tool to evaluate and develop sensorized myoelectric prosthesis technology.

17 August 2018 in Neuromodulation: Technology at the Neural Interface
Verified
Journal Article
Closed access
PDF file
CDChristopher C. Duncan
Christopher C. Duncan
DKDavid T. Kluger
David T. Kluger
TDTyler S. Davis
Tyler S. Davis
DWDavid J. Warren
David J. Warren
DPDavid M. Page
David M. Page
GCGregory A. Clark
Gregory A. Clark