Postprocedural aortic regurgitation occurs in 10 to 20% of patients undergoing transcatheter aortic-valve replacement (TAVR) for aortic stenosis. We hypothesized that assessment of defects in high-molecular-weight (HMW) multimers of von Willebrand factor or point-of-care assessment of hemostasis could be used to monitor aortic regurgitation during TAVR. We enrolled 183 patients undergoing TAVR. Patients with aortic regurgitation after the initial implantation, as identified by means of transesophageal echocardiography, underwent additional balloon dilation to correct aortic regurgitation. HMW multimers and the closure time with adenosine diphosphate (CT-ADP), a point-of-care measure of hemostasis, were assessed at baseline and 5 minutes after each step of the procedure. Mortality was evaluated at 1 year. A second cohort (201 patients) was studied to validate the use of CT-ADP in order to identify patients with aortic regurgitation. After the initial implantation, HMW multimers normalized in patients without aortic regurgitation (137 patients). Among the 46 patients with aortic regurgitation, normalization occurred in 20 patients in whom additional balloon dilation was successful but did not occur in the 26 patients with persistent aortic regurgitation. A similar sequence of changes was observed with CT-ADP. A CT-ADP value of more than 180 seconds had sensitivity, specificity, and negative predictive value of 92.3%, 92.4%, and 98.6%, respectively, for aortic regurgitation, with similar results in the validation cohort. Multivariable analyses showed that the values for HMW multimers and CT-ADP at the end of TAVR were each associated with mortality at 1 year. The presence of HMW-multimer defects and a high value for a point-of-care hemostatic test, the CT-ADP, were each predictive of the presence of aortic regurgitation after TAVR and were associated with higher mortality 1 year after the procedure. (Funded by Lille 2 University and others; ClinicalTrials.gov number, NCT02628509.)
Background —Monocytic tissue factor (TF) expression may contribute to thrombogenicity associated with plaque rupture and may propagate thrombus formation at the site of vascular lesions. Induction of monocytic TF expression by endotoxin is mediated by the activation of transcription factors such as AP-1 and NF-κB. Both these signaling pathways are modulated by peroxisome proliferator–activated receptor-α (PPARα). Therefore, we have studied the effects of fibrates and other PPARα agonists on the expression of TF. Methods and Results —We show that PPARα protein, like primary human monocytes, is also expressed in the human monocytic THP-1 cell line. Fenofibric acid, WY14643, and GW2331 inhibited TF mRNA upregulation after stimulation of THP-1 cells with lipopolysaccharide or interleukin-1β. In primary human monocytes and macrophages, the lipopolysaccharide- or interleukin-1β–mediated induction of TF activity was also inhibited by fenofibric acid, WY14643, or GW2331. Conclusions —These data indicate that activation of PPARα results in the downregulation of the TF gene. Our results suggest a novel role for PPARα in the control of atherosclerotic plaque thrombogenicity through its effects on TF expression in monocytes and macrophages.
Rationale:: Percutaneous aortic valve procedures are a major breakthrough in the management of patients with aortic stenosis. Residual gradient and residual aortic regurgitation are major predictors of midterm and long-term outcome after percutaneous aortic valve procedures. We hypothesized that (1) induction/recovery of high molecular weight (HMW) multimers of von Willebrand factor defect could be instantaneous after acute changes in blood flow, (2) a bedside point-of-care assay (platelet function analyzer-closure time adenine DI-phosphate [PFA-CADP]), reflecting HMW multimers changes, could be used to monitor in real-time percutaneous aortic valve procedures. Objective:: To investigate the time course of HMW multimers changes in models and patients with instantaneous induction/reversal of pathological high shear and its related bedside assessment. Methods and Results:: We investigated the time course of the induction/recovery of HMW multimers defects under instantaneous changes in shear stress in an aortic stenosis rabbit model and in patients undergoing implantation of a continuous flow left ventricular assist device. We further investigated the recovery of HMW multimers and monitored these changes with PFA-CADP in aortic stenosis patients undergoing transcatheter aortic valve implantation or balloon valvuloplasty. Experiments in the aortic stenosis rabbit model and in left ventricular assist device patients demonstrated that induction/recovery of HMW multimers occurs within 5 minutes. Transcatheter aortic valve implantation patients experienced an acute decrease in shear stress and a recovery of HMW multimers within minutes of implantation which was sustained overtime. In patients with residual high shear or with residual aortic regurgitation, no recovery of HMW multimers was observed. PFA-CADP profiles mimicked HMW multimers recovery both in transcatheter aortic valve implantation patients without aortic regurgitation (correction) and transcatheter aortic valve implantation patients with aortic regurgitation or balloon valvuloplasty patients (no correction). Conclusions:: These results demonstrate that variations in von Willebrand factor multimeric pattern are highly dynamic, occurring within minutes after changes in blood flow. It also demonstrates that PFA-CADP can evaluate in real time the results of transcatheter aortic valve procedures.